High Pressure filters Maximum pressure up to 350 bar - Flow rate up to 500 l/min Filter housing according to SAE J2066 for HF4 filter elements Mraimr- 495 High Pressure filters
Open the catalog to page 1FILTER SIZING Corrective factor FILTER SIZING Corrective factor The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for the return filter the pressure drop have to be in the range 0.4 - 0.6 bar. Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s The pressure drop calculation is performed by adding together the value of the housing with the value of the filter element. The pressure drop in the housing...
Open the catalog to page 2Corrective factor FILTER SIZING Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s Suction filters Low & Medium pressure filters Filter element Return / Suction filters Filter element Filter element
Open the catalog to page 3Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s Stainless steel high pressure filters Filter elemen Filter element Filter element Filter element
Open the catalog to page 4Selection Software FILTER SIZING Step Select “FILTERS” Choose filter group (Return Filter, Pressure Filter, etc.) Choose filter type (MPF, MPT, etc.) in function of the max working pressure and the max flow rate Push “PROCEED” Insert all application data to calculate the filter size following the sequence: - working pressure - working flow rate - working pressure drop - working temperature - fluid material and fluid type - filtration media - connection type Push “CALCULATE” to have result; in case of any mistake, the system will advice which parameter is out of range to allow to modify/adjust...
Open the catalog to page 5High Pressure filters
Open the catalog to page 6High Pressure filters Maximum pressure up to 350 bar - Flow rate up to 500 l/min Filter housing according to SAE J2066 for HF4 filter elements Mraimr- 495 High Pressure filters
Open the catalog to page 7High Pressure filters Maximum pressure up to 350 bar - Flow rate up to 500 l/min Filter housing materials - Head: Phosphatized cast iron - Housing: Phosphatized steel - Cover: Cast iron (chemical heat treatment) - Bypass valve: Brass - Steel Bypass valve - Opening pressure 600 kPa (6 bar) - Other opening pressures on request. Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: 35 MPa (350 bar) - Test pressure: 52.5 MPa (525 bar) - Burst pressure: 105 MPa (1050 bar) - Pulse pressure fatigue test: 1 000 000 cycles with pressure from 0 to 35 MPa (350 bar) Ap element...
Open the catalog to page 8GENERAL INFORMATION Filter housing according to SAE J2066 for HF4 filter elements The curves are plotted using mineral oil with density of 0.86 kg/dm3 in compliance with ISO 3968. ∆p varies proportionally with density. 1.50 Pressure drop Filter housings ∆p pressure drop Flow rate l/min
Open the catalog to page 9FHF325 Designation & Ordering code COMPLETE FILTER Configuration example: Without bypass With bypass 6 bar Connection for differential indicator With two connections plugged on both sides Filtration rating (filter media) A03 Inorganic microfiber 3 µm A06 Inorganic microfiber 6 µm A10 Inorganic microfiber 10 µm A16 Inorganic microfiber A25 Inorganic microfiber M25 Wire mesh P01 MP Filtri standard Pxx Customized FILTER ELEMENT Configuration example: Element series and size Element length Filtration rating (filter media) A03 Inorganic microfiber 3 µm A06 Inorganic microfiber 6 µm A10 Inorganic microfiber...
Open the catalog to page 10FHF325 Dimensions FHF325 Connection A - B - C Filter length 1 2 3 Recommended clearance space for maintenance High Pressure filters
Open the catalog to page 11FHF325 Dimensions FHF325 Connection G - H Filter length 1 2 3 Recommended clearance space for maintenance High Pressure filters
Open the catalog to page 12FHF325 FHF325 Connection M - N Filter length 1 2 3 Recommended clearance space for maintenance High Pressure filters
Open the catalog to page 13Order number for spare parts FHF 325 Connections A - B - C - G - H Filter series Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM High Pressure filters
Open the catalog to page 1431 Pages
17 Pages
17 Pages
21 Pages
28 Pages
72 Pages
24 Pages
46 Pages
140 Pages
76 Pages
76 Pages
102 Pages
168 Pages
160 Pages
72 Pages
230 Pages
17 Pages
16 Pages
21 Pages
19 Pages
14 Pages
78 Pages
20 Pages
6 Pages
12 Pages
4 Pages
2 Pages
8 Pages
6 Pages
4 Pages
8 Pages
8 Pages
6 Pages
4 Pages
26 Pages
4 Pages
7 Pages
10 Pages
8 Pages
18 Pages
15 Pages
1 Page
4 Pages
4 Pages
4 Pages
20 Pages
10 Pages
5 Pages
25 Pages
4 Pages
12 Pages
8 Pages
78 Pages
10 Pages
4 Pages
14 Pages
116 Pages
108 Pages
64 Pages
68 Pages
19 Pages