CLOGGING INDICATORS
24Pages

{{requestButtons}}

Catalog excerpts

CLOGGING INDICATORS - 1

Clogging Indicators Clogging indicators are devices that check the life time of the filter elements. They measure the pressure drop through the filter element directly connected to the filter housing. These devices trip when the clogging of the filter element causes a pressure drop increasing across the filter element. Filter elements are efficient only if their Dirt Holding Capacity is fully exploited. This is achieved by using filter housings equipped with clogging indicators. The indicator is set to alarm before the element becomes fully clogged. MP Filtri can supply indicators of the following designs: - Vacuum switches and gauges - Pressure switches and gauges - Differential pressure indicators These type of devices can be provided with a visual, electrical or both signals. The electronic differential pressure clogging indicator is also available. It provides both analogical 4-20 mA output and digital warning (75% of clogging) and alarm (clogging) outputs.

Open the catalog to page 1
CLOGGING INDICATORS - 3

Clogging indicators Clogging indicators Suitable indicator types VACUUM INDICATORS Vacuum indicators are used on the Suction line to check the efficiency of the filter element. They measure the pressure downstream of the filter element. Standard items are produced with R 1/4” EN 10226 connection. Available products with R 1/8” EN 10226 to be fitted on MPS series. BAROMETRIC INDICATORS Pressure indicators are used on the Return line to check the efficiency of the filter element. They measure the pressure upstream of the filter element. Standard items are produced with R 1/8” EN 10226...

Open the catalog to page 3
CLOGGING INDICATORS - 4

Hydraulic symbol Electrical Vacuum Indicator R EN 10226 - R1/4” EN 10226 - R1/8” GREEN LAMP Electrical symbol GREEN LAMP GREEN LAMP GREEN LAMP Clogging Indicators GREEN LAMP GREEN LAMP EN 175301-803 GREEN RED LAMP 51 LAMP 52 53 24 Vdc 110 Vdc 230 Vac 1 A / 24 Vdc 1 A / 110 Vdc 1 A / 230 Vac GREEN LAMP Materials - Body: - Base: - Contacts: - Seal: Brass Black Nylon Silver NBR Electrical/Visual Vacuum Indicator Connections EN 10226 - R1/4” EN 10226 - R1/8” Electrical data 2 2 3 - Electrical connection: 4 5 - Type 5 - Lamps - Resistive load: Brass Transparent Nylon Brass - Nylon NBR Technical...

Open the catalog to page 4
CLOGGING INDICATORS - 5

VACUUM INDICATORS Axial Vacuum Gauge Hydraulic symbol 0 Dial scale Materials - Case: - Window: - Dial: - Pointer: - Pressure connection: - Pressure element: Technical data - Max working pressure: Painted Steel Transparent plastic Painted Steel Painted Aluminium Brass Bourdon tube Cu-alloy soft soldered Working temperature: Compatibility with fluids: Accuracy: Degree of protection: Static: 7 bar Fluctuating: 6 bar Short time: 10 bar From -40 °C to +60 °C Mineral oils, Synthetic fluids HFA, HFB, HFC according to ISO 2943 Class 2.5 according to EN 13190 IP31 according to EN 60529 Materials -...

Open the catalog to page 5
CLOGGING INDICATORS - 6

Dimensions BEA*50 Hydraulic symbol Electrical Pressure Indicator Materials - Body: - Base: - Contacts: - Seal: Brass Black Nylon Silver HNBR BEM*41 Electrical Pressure Indicator Settings Ordering code Electrical symbol ®o ©o ©O ®o Hydraulic symbol Technical data - Max working pressure: - Proof pressure: - Working temperature: - Compatibility with fluids: - Degree of protection: Electrical data - Electrical connection: - Resistive load: 40 bar 60 bar From -25 °C to +80 °C Mineral oils, Synthetic fluids HFA, HFB, HFC according to ISO 2943 IP65 according to EN 60529 - Available Atex product: -...

Open the catalog to page 6
CLOGGING INDICATORS - 7

Materials - Body: - Base: - Contacts: - Seal: Hydraulic symbol Electrical Pressure Indicator 2 2 Thermal lockout Technical data - Max working pressure: 10 bar - Proof pressure: 15 bar - Working temperature: From -25 °C to +100 °C - Compatibility with fluids: Mineral oils, Synthetic fluids N.C. HFA, HFB, HFC according to ISO 2943 - Degree of protection: IP65 according to EN 60529 Electrical symbol Electrical data - Electrical connection: Deutsch DT-04-2-P - Resistive load: 0.5 A / 48 Vdc - Thermostat condition: Open up to 30 °C - CE certification Hydraulic symbol Electrical Pressure...

Open the catalog to page 7
CLOGGING INDICATORS - 8

Hydraulic symbol Electrical/Visual Pressure Indicator Settings Ordering code 1.5 bar ±10% 2 bar ±10% Materials - Body: - Base: - Contacts: - Seal: Brass Black Nylon Silver HNBR Technical data - Max working pressure: 40 bar - Proof pressure: 60 bar - Working temperature: From -25 °C to +80 °C - Compatibility with fluids: Mineral oils, Synthetic fluids HFA, HFB, HFC according to ISO 2943 - Degree of protection: IP65 according to EN 60529 Electrical data - Electrical connection: - Lamps: - Resistive load: BVA Axial Pressure Gauge Settings Ordering code Hydraulic symbol BVR Radial Pressure...

Open the catalog to page 8
CLOGGING INDICATORS - 9

BAROMETRIC INDICATORS BVP - BVQ Visual Pressure Indicator Settin Ordering code BV P 15 H P01 BV Q 15 H P01 BV P 20 H P01 BV Q 20 H P01 Materials - Body: - Cover / internal parts: - Caps: - Seal: Technical data - Reset: Brass Nylon VMQ HNBR BVP - Automatic reset BVQ - Manual reset 10 bar 15 bar From -25 °C to +80 °C - Compatibility with fluids: Mineral oils, Synthetic fluids HFA, HFB, HFC according to ISO 2943 - Degree of protection: IP45 according to EN 60529 - Max working pressure: - Proof pressure: - Working temperature: Signals DESIGNATION & ORDERING CODE BE Electrical pressure indicator...

Open the catalog to page 9
CLOGGING INDICATORS - 10

Dimensions DEA*50 Hydraulic symbol Electrical Differential Indicator Settings Ordering code 1.2 bar ±10% 2 bar ±10% Materials - Body: - Base: - Contacts: - Seal: Brass Black Nylon Silver HNBR-FPM Technical data - Max working pressure: - Proof pressure: - Burst pressure: - Working temperature: 420 bar 630 bar 1260 bar From -25 °C to +110 °C - Compatibility with fluids: Mineral oils, Synthetic fluids HFA, HFB, HFC according to ISO 2943 - Degree protection: IP66 according to EN 60529 IP69K according to ISO 20653 Electrical data - Electrical connection: EN 175301-803 DEH*48 Connection diagram...

Open the catalog to page 10
CLOGGING INDICATORS - 11

DEH*70 Connection diagram Hazardous Area Electronic Differential Indicator SettingsOrdering code DIFFERENTIAL INDICATORS Dimensions Materials - Body: - Contacts: - Seal: Protection class AISI 316 Stainless steel housing with internal engineered resin switch Rhodium MFQ - FPM EX ia IIC T6: Intrinsically safe Temperature class T6 (85 °C) Technical data - Max working pressure: 420 bar - Working temperature: From -20 °C to +80 °C - Connection type: 4 pole male M12 connector - plastic - Contact type: SPCO/SPDT (Hermetically sealed - volt free contacts) - Compatibility with fluids: Mineral oils,...

Open the catalog to page 11

All MP Filtri catalogs and technical brochures

  1. LMS/LDS Series

    17 Pages

  2. LMC/LDC Series

    17 Pages

  3. LMG Series

    21 Pages

  4. ACCESSORIES

    28 Pages

  5. BELL HOUSING

    72 Pages

  6. COUPLINGS

    46 Pages

  7. Return Filters

    230 Pages

  8. FHD - DUPLEX

    17 Pages

  9. FHB - MANIFOLD

    16 Pages

  10. FHM - MANIFOLD

    21 Pages

  11. FHP

    19 Pages

  12. FMP

    14 Pages

  13. Spin-On Filter

    78 Pages

  14. LMP 124

    6 Pages

  15. MRSX

    12 Pages

  16. MSH

    4 Pages

  17. MPS

    8 Pages

  18. FMP 039

    4 Pages

  19. FRI

    10 Pages

  20. MPI

    8 Pages

  21. MPH

    18 Pages

  22. MPT

    15 Pages

  23. MST

    4 Pages

  24. STR

    4 Pages

  25. RF2

    4 Pages

  26. MPF

    20 Pages

  27. LMP 400 - 430

    10 Pages

  28. LMP 210

    5 Pages

  29. FAS

    4 Pages

  30. SF2 500

    12 Pages

  31. SF2 250

    8 Pages

  32. SA - SAP

    10 Pages

  33. STR

    4 Pages

  34. In-line filters

    108 Pages

  35. Accessories

    68 Pages

  36. Catalogue

    19 Pages