Clogging Indicators Clogging indicators are devices that check the life time of the filter elements. They measure the pressure drop through the filter element directly connected to the filter housing. These devices trip when the clogging of the filter element causes a pressure drop increasing across the filter element. Filter elements are efficient only if their Dirt Holding Capacity is fully exploited. This is achieved by using filter housings equipped with clogging indicators. The indicator is set to alarm before the element becomes fully clogged. MP Filtri can supply indicators of the following designs: - Vacuum switches and gauges - Pressure switches and gauges - Differential pressure indicators These type of devices can be provided with a visual, electrical or both signals. The electronic differential pressure clogging indicator is also available. It provides both analogical 4-20 mA output and digital warning (75% of clogging) and alarm (clogging) outputs.
Open the catalog to page 1Clogging indicators Clogging indicators Suitable indicator types VACUUM INDICATORS Vacuum indicators are used on the Suction line to check the efficiency of the filter element. They measure the pressure downstream of the filter element. Standard items are produced with R 1/4” EN 10226 connection. Available products with R 1/8” EN 10226 to be fitted on MPS series. BAROMETRIC INDICATORS Pressure indicators are used on the Return line to check the efficiency of the filter element. They measure the pressure upstream of the filter element. Standard items are produced with R 1/8” EN 10226...
Open the catalog to page 3Hydraulic symbol Electrical Vacuum Indicator R EN 10226 - R1/4” EN 10226 - R1/8” GREEN LAMP Electrical symbol GREEN LAMP GREEN LAMP GREEN LAMP Clogging Indicators GREEN LAMP GREEN LAMP EN 175301-803 GREEN RED LAMP 51 LAMP 52 53 24 Vdc 110 Vdc 230 Vac 1 A / 24 Vdc 1 A / 110 Vdc 1 A / 230 Vac GREEN LAMP Materials - Body: - Base: - Contacts: - Seal: Brass Black Nylon Silver NBR Electrical/Visual Vacuum Indicator Connections EN 10226 - R1/4” EN 10226 - R1/8” Electrical data 2 2 3 - Electrical connection: 4 5 - Type 5 - Lamps - Resistive load: Brass Transparent Nylon Brass - Nylon NBR Technical...
Open the catalog to page 4VACUUM INDICATORS Axial Vacuum Gauge Hydraulic symbol 0 Dial scale Materials - Case: - Window: - Dial: - Pointer: - Pressure connection: - Pressure element: Technical data - Max working pressure: Painted Steel Transparent plastic Painted Steel Painted Aluminium Brass Bourdon tube Cu-alloy soft soldered Working temperature: Compatibility with fluids: Accuracy: Degree of protection: Static: 7 bar Fluctuating: 6 bar Short time: 10 bar From -40 °C to +60 °C Mineral oils, Synthetic fluids HFA, HFB, HFC according to ISO 2943 Class 2.5 according to EN 13190 IP31 according to EN 60529 Materials -...
Open the catalog to page 5Dimensions BEA*50 Hydraulic symbol Electrical Pressure Indicator Materials - Body: - Base: - Contacts: - Seal: Brass Black Nylon Silver HNBR BEM*41 Electrical Pressure Indicator Settings Ordering code Electrical symbol ®o ©o ©O ®o Hydraulic symbol Technical data - Max working pressure: - Proof pressure: - Working temperature: - Compatibility with fluids: - Degree of protection: Electrical data - Electrical connection: - Resistive load: 40 bar 60 bar From -25 °C to +80 °C Mineral oils, Synthetic fluids HFA, HFB, HFC according to ISO 2943 IP65 according to EN 60529 - Available Atex product: -...
Open the catalog to page 6Materials - Body: - Base: - Contacts: - Seal: Hydraulic symbol Electrical Pressure Indicator 2 2 Thermal lockout Technical data - Max working pressure: 10 bar - Proof pressure: 15 bar - Working temperature: From -25 °C to +100 °C - Compatibility with fluids: Mineral oils, Synthetic fluids N.C. HFA, HFB, HFC according to ISO 2943 - Degree of protection: IP65 according to EN 60529 Electrical symbol Electrical data - Electrical connection: Deutsch DT-04-2-P - Resistive load: 0.5 A / 48 Vdc - Thermostat condition: Open up to 30 °C - CE certification Hydraulic symbol Electrical Pressure...
Open the catalog to page 7Hydraulic symbol Electrical/Visual Pressure Indicator Settings Ordering code 1.5 bar ±10% 2 bar ±10% Materials - Body: - Base: - Contacts: - Seal: Brass Black Nylon Silver HNBR Technical data - Max working pressure: 40 bar - Proof pressure: 60 bar - Working temperature: From -25 °C to +80 °C - Compatibility with fluids: Mineral oils, Synthetic fluids HFA, HFB, HFC according to ISO 2943 - Degree of protection: IP65 according to EN 60529 Electrical data - Electrical connection: - Lamps: - Resistive load: BVA Axial Pressure Gauge Settings Ordering code Hydraulic symbol BVR Radial Pressure...
Open the catalog to page 8BAROMETRIC INDICATORS BVP - BVQ Visual Pressure Indicator Settin Ordering code BV P 15 H P01 BV Q 15 H P01 BV P 20 H P01 BV Q 20 H P01 Materials - Body: - Cover / internal parts: - Caps: - Seal: Technical data - Reset: Brass Nylon VMQ HNBR BVP - Automatic reset BVQ - Manual reset 10 bar 15 bar From -25 °C to +80 °C - Compatibility with fluids: Mineral oils, Synthetic fluids HFA, HFB, HFC according to ISO 2943 - Degree of protection: IP45 according to EN 60529 - Max working pressure: - Proof pressure: - Working temperature: Signals DESIGNATION & ORDERING CODE BE Electrical pressure indicator...
Open the catalog to page 9Dimensions DEA*50 Hydraulic symbol Electrical Differential Indicator Settings Ordering code 1.2 bar ±10% 2 bar ±10% Materials - Body: - Base: - Contacts: - Seal: Brass Black Nylon Silver HNBR-FPM Technical data - Max working pressure: - Proof pressure: - Burst pressure: - Working temperature: 420 bar 630 bar 1260 bar From -25 °C to +110 °C - Compatibility with fluids: Mineral oils, Synthetic fluids HFA, HFB, HFC according to ISO 2943 - Degree protection: IP66 according to EN 60529 IP69K according to ISO 20653 Electrical data - Electrical connection: EN 175301-803 DEH*48 Connection diagram...
Open the catalog to page 10DEH*70 Connection diagram Hazardous Area Electronic Differential Indicator SettingsOrdering code DIFFERENTIAL INDICATORS Dimensions Materials - Body: - Contacts: - Seal: Protection class AISI 316 Stainless steel housing with internal engineered resin switch Rhodium MFQ - FPM EX ia IIC T6: Intrinsically safe Temperature class T6 (85 °C) Technical data - Max working pressure: 420 bar - Working temperature: From -20 °C to +80 °C - Connection type: 4 pole male M12 connector - plastic - Contact type: SPCO/SPDT (Hermetically sealed - volt free contacts) - Compatibility with fluids: Mineral oils,...
Open the catalog to page 11All MP Filtri catalogs and technical brochures
-
MULTI-COMPONENTS
31 Pages
-
LMS/LDS Series
17 Pages
-
LMC/LDC Series
17 Pages
-
LMG Series
21 Pages
-
ACCESSORIES
28 Pages
-
BELL HOUSING
72 Pages
-
COUPLINGS
46 Pages
-
CONTAMINATION CONTROL SOLUTIONS
140 Pages
-
Return / Suction Filters
76 Pages
-
SPIN-ON FILTERS
76 Pages
-
Stainless Steel Filters
102 Pages
-
Low & Medium Pressure Filters
168 Pages
-
High Pressure Filters
160 Pages
-
Suction Filters
72 Pages
-
Return Filters
230 Pages
-
FHD - DUPLEX
17 Pages
-
FHF 325 - MANIFOLD
14 Pages
-
FHB - MANIFOLD
16 Pages
-
FHM - MANIFOLD
21 Pages
-
FHP
19 Pages
-
FMP
14 Pages
-
Spin-On Filter
78 Pages
-
Stainless Steel
20 Pages
-
LMP 124
6 Pages
-
MRSX
12 Pages
-
MSH
4 Pages
-
CS - CG - CW - CT
2 Pages
-
MPS
8 Pages
-
LMP 952 - 954
6 Pages
-
LMP 900 - 901
4 Pages
-
LMD 400 - 401 - 431 DUPLEX
8 Pages
-
LMP MULTIPORT
8 Pages
-
FMM 050 - FHA 051
6 Pages
-
FMP 039
4 Pages
-
Clogging Indicators
26 Pages
-
SF2 250 - 350
4 Pages
-
Suction Strainer
7 Pages
-
FRI
10 Pages
-
MPI
8 Pages
-
MPH
18 Pages
-
MPT
15 Pages
-
filter element CH
1 Pages
-
MST
4 Pages
-
STR
4 Pages
-
RF2
4 Pages
-
MPF
20 Pages
-
LMP 400 - 430
10 Pages
-
LMP 210
5 Pages
-
LMP 110-120-123 MULTIPORT
25 Pages
-
FAS
4 Pages
-
SF2 500
12 Pages
-
SF2 250
8 Pages
-
Structural components
78 Pages
-
SA - SAP
10 Pages
-
STR
4 Pages
-
Condition monitoring products
14 Pages
-
Pressure filters
116 Pages
-
In-line filters
108 Pages
-
Structural components
64 Pages
-
Accessories
68 Pages
-
Catalogue
19 Pages