R4FC

R4FC

R4FC

Product catalog summary
Overview: The document describes an electronic controller designed for electromagnetic vibratory feeders. It is characterized by its stability, optoisolation, compactness, and cost-effectiveness. The controller is available in various configurations, including circuit-only, circuit with DIN35 support, and external potentiometer, housed in either plastic or metallic boxes.
General Characteristics: The controller operates at 115V/230V with a frequency of 50/60 Hz and supports 3000/6000 vibrations per minute (vpm). It features multiple ON/OFF inputs with dual logic, adjustable slow/fast ramp times, and regulation of minimum and maximum vibration levels. It includes a line input with a Schuko plug and a vibrator output with a connector. The controller also supports automatic input ranging from 0/5V to 0/10V, with LED indicators for ON (green) and OFF (red) states.
Applications: The controller is suitable for regulating linear feeders and small bowl feeders with a maximum current of 5 Amps.
Options: Available options include an IP65 (NEMA 4/4X) box, an INOX box, customized labels, double speed functionality, and a connector for the vibrator. It can also be equipped with PRX92-PRX99 circuits for NPN-PNP sensors.
Technical Specifications:
  • Feeding Tension: 115/230V ± 10% – 50/60 Hz
  • Consumption: 1 W max
  • Max Current - Min Load: 5 A (RMS) - 30 mA (RMS)
  • Automatic Input: 0/5V-0/10V-0/20 mAmp
  • Frequency of Vibration: 3000/6000 vpm (50 Hz) RC-AC
  • Ramp Time: 0.1 sec. / 1 sec. (adjustable)
  • Min Regulation: 80 V ± 30% (230V)
  • Max Regulation: 220 V - 30% (230V)
  • On/Off: Free voltage contact/voltage signal 0/24Vcc
  • Protection Degree: IP55 in box (IP65-NEMA4-4X)
  • Storage Temperature: –10°C / +80°C
  • Operation Temperature: –5°C / +55°C
  • European Norms: EMC CE
  • Warranty: 1 year from the date on the circuit
Available Versions: The controller is available in several versions with different box types and dimensions, including circuit-only, DIN circuit, fire-retardant plastic, and aluminum boxes, each with specific dimensions and codes.
Adjustment Instructions: The document provides instructions for adjusting the minimum and maximum settings using voltage inputs, with specific calibration for 3000 and 6000 vpm settings.
See more

Catalog excerpts

R4FC-1

Electronic Controller for Electromagnetic Vibratory Feeders General Stabilized, optoisolated, compact and economic controller. This controller is available in the following versions: only circuit, circuit with DIN35 support and external potentiometer, plastic or metallic box. METALLIC BOX PV R4FC Z2 STM 140x115x60 General Characteristics Voltage 115V/230V, 50/60 Hz • 3000/6000 vpm • Multiple ON/OFF input with double logic • Slow/fast ramp • Reg. vibration min/max • Line input with schuko plug • Vibrator output with connector • Automatic Input 0/5V-0/10V • Led ON (green) • Led OFF (red). Applications Regulation of linear feeders and small bowl feeders till 5 Amps. Options Box IP65 (NEMA 4/4X) • INOX Box • Customized label • Double speed • Connector for vibrator • Available with PRX92-PRX99 circuits for NPN-PNP sensor. Technical Specs Feeding Tension: Automatic Input: Ramp Time: free voltage contact/voltage signal 0/24Vcc Protection Degree: Storage Temperature: Operation Temperature: European Norms: 1 year (from date on circuit) Available Versions Type Fire-retardant plastic

 Open the catalog to page 1
R4FC-2

ON/OFF FREE VOLTAGE CONCTAT ON/OFF FREE VOLTAGE CONTACT FAST RAMP ADJUSTMENT: WITH 0V ADJUST THE MINIMUM WITH 5V ADJUST THE MAXIMUM THE MINIMUM IS NOT INFLUENCED THE MAXIMUM IS INFLUENCED BY THE MINIMUM 3000 AND 6000 HAVE DIFFERENT CALIBRATION Description: ELECTRONIC CIRCUIT R4FC CODE

 Open the catalog to page 2

All MP Elettronica Srl catalogs and technical brochures

  1. Short Form EN

    10  Pages

  2. CV6/17-CV8/17

    2  Pages

  3. FQ1N – FQ2N

    2  Pages

  4. CV6 – CV8

    2  Pages

  5. VBS06

    2  Pages

  6. R3FC

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.