CARE Motion Segment Product Overview

Open the catalog to page 2
Care - 3

of TiMOTION’s customer application requirements can be solved by our experienced personnel providing highly customized solutions. TiMOTION guarantees complete customer satisfaction by providing a competitive packaged actuator solution coupled with a wide range of high quality products, global service networks and “on demand” R&D resources. Your BEST choice of actuation system for medical applications With an aging population and increasing healthcare needs, the medical segment is seeking the best solutions that can improve the stay in a hospital for patients and staff. Our Care Motion...

Open the catalog to page 3
Care - 4

CARE Motion Segment Product Overview High Customization with Complete Flexibility Whether you are looking for a specific actuator with unique spec, having special software function, or even hoping to design special user interface on the handset, you have come to the right place. With dedicated R&D resources, we can design what you need upon individual requests. More importantly, the average software development time is within 7 working days (note 1) which will help your new products to be released to the market on time. Note 1: the real development time is decided by the complexity of...

Open the catalog to page 4
Care - 5

Bluetooth Control System with Mobile Devices More and more mobile devices, either with an iOS or Android system, are becoming a trendy media that can work as a remote controller especially in a home care application. As an innovative solution provider, TiMOTION created this system to offer more alternatives when it comes to home care application. Wireless Technology Implementation for Home Care Applications When it comes to home care applications, wireless technology is a crucial factor for seamless digital communication which can help caregivers to control the medical devices remotely...

Open the catalog to page 5
Care - 6

CARE Motion Segment Product Overview More than a single product, we provide you with a total solution We understand most customers are confronted with critical challenges ahead and hope to obtain one single solution that can be perfectly customized upon their requests. This is why you need TiMOTION; we make your dreams into reality. Control Systems Manual Crank Attachment for Unstable Electricity Source Applied to where the electricity source is unreliable. Out of Bed Detection Automatically activate an alarm and keep the caregivers informed when the patient leaves the bed. Manual Release...

Open the catalog to page 6
Care - 8

CARE Motion Segment Product Overview TA1 SERIES Maximum load 10,000N in push Maximum load 4,000N in pull Maximum speed at no load 38.0mm/s Maximum speed at full load 23.2mm/s Minimum installation dimension stroke+163mm IP rating up to IP66 Certificate IEC60601-1, ES60601-1, and RoHS compliant CODE Rated Load PUSHN PULLN Self Locking N (PUSH) Typical Current at Rated Load (A) Note 1 The above are the speed and current figures under pushing condition. 2 Speed would be the same if with 12V motor, but with double current consumption comparing 24V motor. 3 If choosing #B, it must use iron...

Open the catalog to page 8
Care - 9

TA7 SERIES Maximum load 10,000N in push Maximum load 4,000N in pull Maximum speed at no load 38.0mm / s Maximum speed at full load 23.2mm / s Minimum installation dimension stroke+171mm IP rating up to IP66 Certificate CODE Rated Load PUSHN PULLN Self Locking N (PUSH) Typical Current at Rated Load (A) Note 1 The above are the speed and current figures under pushing condition. 2 Speed would be the same if with 12V motor, but with double current consumption comparing 24V motor. 3 The self locking force above needs to work with TiMOTION control system.

Open the catalog to page 9
Care - 10

CARE Motion Segment Product Overview Linear Actuator Maximum load 6,000N in push Maximum load 4,000N in pull With manual crank function CODE Rated Load PUSHN PULLN Self Locking N (PUSH) Typical Current at Rated Load (A) Note 1 The above are the speed and current figures under pushing condition. 2 Speed would be the same if with 12V motor, but with double current consumption comparing 24V motor.

Open the catalog to page 10
Care - 11

Linear Actuator Certificate RoHS, ES60601 -1 and IEC60601-1 compliant Special design for patient hoist as a lifting actuator CODE Rated Load PUSHN PULLN Self Locking N (PUSH) Typical Current at Rated Load (A) Note 1 The above are the speed and current figures under pushing condition. 2 Speed would be the same if with 12V motor, but with double current consumption 3 When choosing code #A or #G, one cannot choose voltage option "#1_12V".

Open the catalog to page 11
Care - 12

CARE Motion Segment Product Overview TA13 SERIES Maximum load 8,000N in push Maximum load 4,000N in pull Maximum speed at no load 10.7mm / s Maximum speed at full load 6.0mm / s Minimum installation dimension stroke+185mm Certificate ES60601-1 and IEC60601-1 Suitable for a dentist chair application Load and Speed CODE Rated Load Self Locking Typical Typical Speed PUSH N PULL N N (PUSH) Current ^ No Load Rated Load Note 1 The above are the speed and current figures under pushing condition.

Open the catalog to page 12
Care - 13

TA15 SERIES Maximum load 8,000N in push Maximum load 4,000N in push Maximum speed at no load 8.4mm / s Maximum speed at full load 4.4mm / s Minimum installation dimension stroke+210mm Color black or grey For bariatric bed application especially Load and Speed CODE Rated Load Self Locking Typical Typical Speed PUSH N PULL N N (PUSH) CUrrent ^ No Load Rated Load Note 1 The above are the speed and current figures under pushing condition.

Open the catalog to page 13
Care - 14

CARE Motion Segment Product Overview Linear Actuator TA16 SERIES Maximum load 2,500N in push Low-noise, small size for easy installation CODE Rated Load Self Locking Typical Typical Speed PUSH/PULL N N (PUSH/PULL) Current at No Load Rated Load

Open the catalog to page 14
Care - 15

TA17 SERIES Maximum load 2,000N in push and pull Maximum speed at no load 25.0mm/s Maximum speed at full load 15.5mm/s Minimum installation dimension stroke+217mm IP rating up to IP66 Certificate An in-line actuator design with compact installation dimension CODE Rated Load PUSHN PULLN Self Locking N (PUSH) Typical Current at Rated Load (A) Note 1 The above are the speed and current figures under pushing condition. 2 Speed would be the same if with 12V motor, but with double current consumption comparing 24V motor. 3 The self locking force above needs to work with TiMOTION control...