Alpenklang Quality and Functional Description
The Alpenklang compact air handling unit by Mountair AG is designed for efficient heat recovery using aluminum plate heat exchangers with a hygroscopic membrane. It features a counterflow plate heat exchanger for heat transfer between warm and cold air flows, with a bypass flap for frost conditions. Additional heating is available via pump warm water (PWW) and optional cooling. EC motors adjust air volumes, and a compact controller manages temperature regulation.

Applications
This unit is suitable for fresh air systems in various settings including restaurants, kitchens, homes, storage rooms, offices, schools, sports halls, and cloakrooms.

Specifications and Standards
The unit complies with DIN EN 1886 (2009) / ISO 14000 standards, featuring L1 housing leakage and T2 heat transition. It includes Bee-Board-Isolation for Minergie® P-Eco compliance and uses a Siemens Synco controller. EC fans meet ErP 2015 standards, and filter cells are energy efficiency class A as per ISO 16890.

Mountair Alpenklang Models
Vertical Model: Offers air flow volumes from 800 to 5000 m3/h with varying dimensions.
Horizontal Model: Similar specifications to the vertical model.
Direct Flow Special Model: Provides similar air flow volumes with additional features for specific applications.

Regulation and Controls
The unit includes fan control options, temperature regulation, and a Siemens Synco controller. Options for anti-freeze protection, electrical filter monitoring, and remote operation are available.

EC Fans
Features direct-drive radial fans with EC motors, ensuring high efficiency and adaptability. Motors are energy class IE4, supporting constant air flow volume.

Heat Recovery and Filters
Utilizes a Belimo damper actuator with a high recovery coefficient. Filters are classified as F7 for supply and return air, with energy class A efficiency.

Specifications Overview
Technical specifications include models such as A23-71 K3G 500-PA23-71 and R3G 500-PB33-01, with voltage range (380–480V), frequency (50/60 Hz), and operational temperature range (-25 to +40°C).

Product Features
Features a high-performance plate heat exchanger for heat recovery, offering up to 90% energy savings. Enthalpy PHEs are available for efficient heat exchange.

Properties and Standards
Models conform to ISO 16890 filter classes (M6, F7, F9) and comply with hygiene guidelines SWKI VA104-01.

Construction and Design Options
Available in vertical or horizontal forms, with options for direct flow special models. Features include cuffs, flaps, and base frame height adjustments.

Technical Data and Customization
Includes system number, air flow volume, external pressure, and filtration levels. Options for air heater and cooler settings, and controller choices are provided.

Contact Information
Mountair AG provides contact details for their locations in Kreuzlingen, Basel, and Suisse Romande.
See more

Catalog excerpts

ALPENKLANG-1

ALPENKLANG Compact air handling unit

 Open the catalog to page 1
ALPENKLANG-2

ALPENKLANG Compact air handling unit

 Open the catalog to page 2
ALPENKLANG-3

ALPENKLANG Compact air handling unit Alpenklang quality First class S2 housing Classification per DIN EN 1886 (2009) / ISO 14000 L1 housing leakage T2 heat transition / TB2 thermal bridging factor Bee-Board-Isolation for Minergie® P-Eco Siemens Synco controller Compact AHU with controls Connection to the control system (BUS) EC fans Continuous and efficient as per ErP 2015 Filter cells Energy efficiency class A as per filter test norm ISO 16890 ePM1 ≥ 70% / F7– 450 ePM1 ≥ 90% / F9– 450 Hygienic design To be cleaned in accordance with VDI 6022 Energy recovery Highest recovery thanks to counterflow...

 Open the catalog to page 3
ALPENKLANG-4

ALPENKLANG Compact air handling unit Mountair Alpenklang Vertical BASIC UNIT, ONE PIECE Base frame Electrical connection

 Open the catalog to page 4
ALPENKLANG-5

ALPENKLANG Compact air handling unit Technical data UNIT SIZE Air flow volume with 2 m/s External pressure Connection Specific fan performance ebm Papst / Ziehl Abegg Heat recovery PHE size Fan Type, incl. EC motor with commutation unit Measurement ring 0 – 10 V Signal incl. air heater Belimo damper actuator, drive axis exterior CR2-53-450 Heat recovery coefficient, humid Pressure loss Room return air RA temperature Air heater incl. frost protection Pump warm-water (PWW) Water volume Outside air and exhaust air separation flap SA: F7 / RA: F7 – Energy class A Differential pressure filter display,...

 Open the catalog to page 5
ALPENKLANG-6

ALPENKLANG Compact air handling unit Mountair Alpenklang Horizontal Drawing and dimensions BASIC DEVICE, ONE PIECE Base frame Electrical connection

 Open the catalog to page 6
ALPENKLANG-7

ALPENKLANG Compact air handling unit Technical data UNIT SIZE Air flow volume with 2 m/s External pressure ebm Papst / Ziehl Abegg Heat recovery PHE size Fan Type, incl. EC motor with commutation unit Measurement ring 0 – 10 V Signal incl. air heater Belimo damper actuator, drive axis exterior CR2-53-450 Heat recovery coefficient, humid Pressure loss Room return air RA temperature Air heater incl. frost protection Pump warm-water (PWW) Water volume Outside air and exhaust air separation flap SA: F7 / RA: F7 – Energy class A Differential pressure filter display, 0 – 250 Pa 400 × 400 410 FS thermostat...

 Open the catalog to page 7
ALPENKLANG-8

ALPENKLANG Compact air handling unit Direct flow special model Drawing and dimensions W BASIC DEVICE, ONE PIECE Base frame Electrical connection

 Open the catalog to page 8
ALPENKLANG-9

ALPENKLANG Compact air handling unit Technical data UNIT SIZE Air flow volume with 2 m/s External pressure ebm Papst / Ziehl Abegg Heat recovery PHE size Fan Type, incl. EC motor with commutation unit Measurement ring 0 – 10 V Signal incl. air heater Belimo damper actuator, drive axis exterior CR2-53-450 Heat recovery coefficient, humid Pressure loss Room return air RA temperature Air heater incl. frost protection Pump warm-water (PWW) Water volume Outside air and exhaust air separation flap SA: F7 / RA: F7 – Energy class A Differential pressure filter display, 0 – 250 Pa 400 × 400 410 FS thermostat...

 Open the catalog to page 9
ALPENKLANG-10

ALPENKLANG Compact air handling unit Regulation / Controls Schema Siemens Synco controller specifications Fans 1 stage timer-controlled with potentiometer (standard without) 2 stages timer-controlled with potentiometer (standard without) Constant pressure Constant flow volume Temperature SA temperature RA temperature SA-RA cascade Bypass (constant damper motor) Air heater (incl. valve/excl. pump) Changeover System Night-time cooling Options Anti-freeze protection with defrost function (T EA) Electrical filter monitoring Without OA and EA flaps Remote operation 0-1-2-Auto Remote signalling: operation,...

 Open the catalog to page 10
ALPENKLANG-11

ALPENKLANG Compact air handling unit The controller is a standard commercially available product. The control cabinet is installed and wired ready for use. Service and maintenance work can be commissioned independently from the manufacturer. The replacement parts are guaranteed, follow-up products are compatible. Controller Standard Siemens Synco controller Parametrizable controller for ventilation devices Extensive functionality Simple operation Fast commissioning Best support from a reliable partner High quality and reliability Field devices Sensors with normalised signals Actuators: Belimo...

 Open the catalog to page 11
ALPENKLANG-12

ALPENKLANG Compact air handling unit In the fans, direct-drive radial fans, so-called free-running fans, are used. Thanks to the large number of finely graduated impellers and motors, the fan that best corresponds to the requirements can be built into the Monoblock. The motors are speed-controlled through electronic commutation units (EC motors) and demonstrate excellent motor efficiency even in the partial load range. The compactly built EC motors are equivalent to the energy class IE4, and do not only allow small Monoblock dimensions but also ensure a constant air flow volume. Increased pressure...

 Open the catalog to page 12
ALPENKLANG-13

ALPENKLANG Compact air handling unit Heat recovery plate heat exchanger (PHE) Heat recovery is ensured through a high-performance plate heat exchanger. It prevents noise transfer and has no movable parts. The heat recovery is also maintenance-free in the long term. The counterflow PHE Up to 90 % energy savings and more in case of condensation Machine-produced “real counterflow exchanger with duct air conveyance” in saltwater-resistant aluminium to achieve a high degree of efficiency across the entire air volume range. The enthalpy PHE Enthalpy plate heat exchangers with the same construction...

 Open the catalog to page 13
ALPENKLANG-14

ALPENKLANG Compact air handling unit Filter cells Filter cells are built into the system with standard dimensions. This allows various filter types to be used without any problems. This ensures that the filtration can be adjusted to changing requirements if needed. Properties All models are available in various depths and with different numbers of bags. Filter classes according to the norm ISO 16890 ISO ePM10 50% (M6) ISO ePM1 70% (F7) ISO ePM1 90% (F9) Energy efficiency class A according to Eurovent High dust holding capacity Recommended final pressure loss: Initial pressure loss × 2, max. however...

 Open the catalog to page 14

All Mountair AG catalogs and technical brochures

  1. HUMIDOS

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.