Overview: The MX150 series is designed for long life and high performance in challenging applications, utilizing fiber brush contact technology. It features standard lead lengths of 72 inches with color-coded wires for easy connections. The series can transmit signals at 2A and handle currents up to 10A at a maximum of 600VAC/VDC.
Specifications:
  • Rings: 2 to 96
  • Current: Signal (2A), Power (10A)
  • Voltage: 600 VDC/VAC
  • Max Speed: 1000 RPM
  • Through Bore Size: 38.1mm (1.5”)
  • Overall Diameter: 99mm (3.9”)
  • Housing Material: Aluminium Alloy
  • Torque: 0.05N.m;+0.03N.m/6rings
  • Contact Material: Precious Metal: Gold-Gold
  • Electrical Noise: <5 mOhm
  • Contact Resistance: <2mOhm
  • Dielectric Strength: 800VDC@50Hz
  • Lead Wire: UL Teflon® Awg22, Awg16
  • Insulation Resistance: 1000MΩ@600VDC
  • Lead Lengths: 300mm (12”)
  • Operating Temperature: -40°C to 80°C
  • Protection: IP51
  • Mechanical Vibration: MIL-SID-810E
  • Humidity: 10% to 85% RH
  • Materials: Lead Free, RoHS compliant
Lead Wire Color Codes: Each ring has a specific color code for easy identification, ranging from black for ring 1 to cyan for ring 12.
Air and Hydraulic Specifications:
  • Air Pressure: 150 PSI
  • Air Temperature: 250°F
  • Hydraulic Temperature: 250°F
  • Max Speed: 1500 RPM
  • Vacuum Pressure: 28 InHG
  • Vacuum Temperature: 250°F
Air Union Specification: Available in sizes 1/2 inch, 3/4 inch, and 1 inch.
Parts and Configurations: The document lists various part numbers with configurations for power and signal channels, ranging from 2 to 96 rings. Each configuration specifies the number of power (10A) and signal (2A) channels.
Usage Recommendations: For systems with multiple channels, a conversion factor is applied to prevent overheating. For example, a 10-channel system should not exceed 50A total, and a 20-channel system should not exceed 80A total, especially in high-temperature environments without airflow.
Important Notes: All voltage and current ratings apply to individual channels/pins only. The overall ampacity is determined by the total number of channels in the system.
See more

Catalog excerpts

MX150 Slip Ring Brochure-1

MX150 series provides a long life, fiber brush contact technology for ultimate performance in many challenging applications. MX150 series are standard, with leads lengths of 72 inches. Color-coded lead wires are used on both the stator and rotor for simplified electrical connections. It can transmit signal (2A), 10A current at max 600VAC/VDC. Air unions are available in 1/2 inch 3/4 inch and 1 inch, please specify when ordering. Please verify indexer model for correct mounting bracket which is included.

 Open the catalog to page 1
MX150 Slip Ring Brochure-2

Parts ListPlease note: 10A rings parallel can be used as multiple 10A current. For Example: 2 rings parallel could be used as 1 wires 20A MX150-02-0200 As a rule of thumb a 10 channel system has a conversion factor of about 0.5, meaning while each channel can handle for example 10A, the total amperage on all channel should not exceed 50A to prevent overheating. On a 20 channel system the conversion factor reduces to about 0.4, meaning the total amerage should not exceed 20 (channel) x 10A (per channel x 0.4 (conversion factor) = 80A. The mentioned convertion factor are worst case estimates when...

 Open the catalog to page 2

All Motion Index Drives, Inc. catalogs and technical brochures

  1. TSR Series

    13  Pages

  2. TT315 Series

    7  Pages

  3. XP Series

    23  Pages

  4. Product Catalog

    152  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.