Catalog excerpts
ADVANCED METALLURGICAL MICROSCOPE
Open the catalog to page 1ADVANCED METALLURGICAL MICROSCOPE otic is expanding the success of its popular BA Series microscope line into the Industrial market, and is pleased to introduce the new BA310MET series, an affordable and powerful Metallurgical microscope line of robust Incident light microscopes. Now Industrial quality control can be performed for all opaque materials like minerals and metal samples with ease and efficiency. Also, the BA310MET performs well in Educational environments of engineering and material professions, where affordability and ease-of-use are key demands. Two other additions are also...
Open the catalog to page 2Daily industrial work environments need a reliable microscope which focuses on ease-of-use as well as on work efficiency. Motic has paid careful attention to these market requirements in order to optimize the BA310MET’s features. The Epi-Illuminator with a 12V/50W Halogen illumination offers a powerful and adjustable light source ideal for all reflective samples. For increased illumination options, an easy replacement of the Halogen bulb is possible by an LED module of different color temperatures (4500K, 6000K). A built-in field diaphragm and aperture diaphragm help to optimize image...
Open the catalog to page 3Objectives For improved optical performance of the BA310MET series, Motic introduces a new generation of Metallurgical LWD objectives. These Plan Achromatic Objectives are made of high quality glass and follow the successful Motic CCIS® Optical concept. Multi-layer coating ensures improved contrast and image quality. The tube lens with focal length F=200mm provides a completely corrected intermediate image, accessible by the photo port exit of the Trinocular head option. Documentation therefore is based on maximum image quality. The ball bearing 5-fold nosepiece shows a reversed orientation...
Open the catalog to page 4Illumination The Epi-Illuminator of the BA310MET models is based on a 12V/50W Halogen light source. The unit’s power supply is separated from the stand to avoid unnecessary heat surrounding the microscope. Like in other Motic models, the Halogen bulb can be replaced by an LED module (4500K or 6000K), simply plugged into the Halogen lamp socket. With an adjustable field diaphragm and aperture diaphragm, homogenous illumination is guaranteed. Careful use of both diaphragms creates a maximum image quality in terms of contrast. The simple polarization set (polarizer & analyzer) enables a useful...
Open the catalog to page 5Eyepiece Tubes Designed with an ergonomic viewing angle of 30º and incorpo- The standard eyepieces, N-WF 10X/20 with high eyepoint for rating an interpupillary distance of 55-75mm, the BA310MET eyeglass wearers, made of high quality optical glass, provide observation tubes guarantee hours of fatigue free viewing. consistent diopter adjustments for both eyes. This enables A large Field of View (20mm) enables fast and comfortable perfect usage of reticles for measuring purposes. Lockable screening. The Trinocular tube allows digital documentation countersunk screws to fix the eyepieces...
Open the catalog to page 6For measuring purposes, the following reticles are available: Graduated linear hair point 0.1mm/10mm Graduated cross hair point 0.1mm/10mm Plain cross hair Stages Depending on the application, four different stages for BA310MET series are available. All stages provide a convenient sample movement with their triple-plate design. The standard stage for BA310MET comes with an area of 180x140mm and 75x50mm travel range. A larger area is offered with the 3”x2”stage for the BA310MET-T. 240x140mm can carry larger samples, while the movement is 75x50mm. For Transmitted light inspections, a glass...
Open the catalog to page 7Documentation Today, accurate documentation has been established as an important part in natural sciences and industrial quality control. The new BA310MET system offers the choice between several imaging options.
Open the catalog to page 8Standard Photomicrography The traditional use of a single lens reflex camera (analogue or digital) requires the Trinocular version of the BA310MET. The adaptation of the camera consists of a mechanical adapter combined with a photo eyepiece (2.5X or 4X) The necessary T2 adapter referring to the camera model is supplied by the camera manufacturer. This setup delivers high resolution images of small fields. Digital Documentation A more convenient setup is provided through Motic’s philosophy of easy image digitization. The combination of the BA310MET with a member of the Moticam series of...
Open the catalog to page 9BA310MET / MET-T Standard Specifications Model Optical System Color Corrected Infinity Optical System [CCIS®] N-WF 10X/20mm, with diopter adjustment Observation Tubes Widefield binocular 30° [F.N. 20] Widefield trinocular 30° [F.N. 20] - light distribution 100:0/20:80 Widefield trinocular 30° [F.N. 20] - light distribution 50:50 fixed, erect image Reversed quintuple BA310MET: 180x140mm surface; 75x50mm movement; coaxial controls BA310MET-T: 240x140mm surface; 75x50mm movement; coaxial controls Brass gears; Z-Axis movement 30mm Fine focus Incident light 12V/50W Halogen illuminator with...
Open the catalog to page 10BA310MET Schematic Diagram (unit:mm) 508.3 BA310MET-T Schematic Diagram (unit:mm) 508.3 BA310MET-H Schematic Diagram (unit:mm) 369
Open the catalog to page 11BA310MET / MET-T System Diagram 2.5X Photo Eyepiece 0.5X C-Mount Camera Adapter 0.65X C-Mount Camera Adapter Siedentopf Trinocular Head (20:80) Siedentopf Binocular Head 1X C-Mount Camera Adapter Siedentopf Trinocular Head (50:50)-Erect Image ND filter (Ø32) Yellow filter (Ø32) Polarizer Blue filter (Ø32) Green filter (Ø32) 12V/3W LED Module (6000K/4500K) Slideglass Holder Glass Plate Wafer Holder Glass Plate
Open the catalog to page 120.5X C-Mount Camera Adapter 0.65X C-Mount Camera Adapter Siedentopf Trinocular Head (20:80) Siedentopf Binocular Head 1X C-Mount Camera Adapter Siedentopf Trinocular Head (50:50)-Erect Image ND filter (Ø32) Yellow filter (Ø32) Polarizer 12V/3W LED Module (6000K/4500K) 12V/50W Halogen Bulb Focusing Block Mechancial Stage
Open the catalog to page 13Canada | China | Germany | Spain | USA Motic Instruments (CANADA) 130 - 4611 Viking Way. Richmond, BC V6V 2K9 Canada Tel: 1-877-977 4717 Fax: 1-604-303 9043 Motic Deutschland GmbH (GERMANY) Christian-Kremp-Strasse 11, D-35578 Wetzlar, Germany Tel: 49-6441-210 010 Fax: 49-6441-210 0122 Motic Incorporation Ltd. (HONG KONG) Rm 2907-8, Windsor House, 311 Gloucester Road, Causeway Bay, Hong Kong Tel: 852-2837 0888 Fax: 852-2882 2792 Motic Spain, S.L. (SPAIN) Polígon Industrial Les Corts, Camí del Mig, 112 08349 Cabrera de Mar, Barcelona, Spain Tel: 34-93-756 6286 Fax: 34-93-756 6287 * CCIS® is a...
Open the catalog to page 14All Motic catalogs and technical brochures
-
AE200
16 Pages
-
Moticam S & T
8 Pages
-
Moticam Pro
8 Pages
-
New Moticam
20 Pages
-
GM 168
2 Pages
-
SMZ 161 / 171
18 Pages
-
SMZ 168
24 Pages
-
VIS 100/ 200
20 Pages
-
PSM 1000
8 Pages
-
AE 2000 MET
12 Pages
-
AE 2000
16 Pages
-
AE 30
16 Pages
-
BA 410
20 Pages
-
BA 310 POL
2 Pages
-
BA 310 E
6 Pages
-
BA 310
12 Pages
-
BA 210 E
4 Pages
-
GM-161/GM-171
12 Pages
-
BA310Pol
2 Pages
-
SMZ-171 BP(Fixed Arm)
2 Pages
-
BA210 Binocular
16 Pages
-
BA210 Binocular
12 Pages