Catalog excerpts
AE2000 ROUTINE LIVE CELL MICROSCOPE SOLUTION
Open the catalog to page 1CONTRAST METHODS The AE2000 microscopes are Motic’s entry models of inverted microscopes, providing a flexible optical concept to meet best image quality and robust design for a long lifetime under rough lab conditions. The AE2000 is the perfect microscope for routine microbiology in clinical and pharmaceutical laboratories, also offering best options for university teaching. In full accordance with Motic’s CCIS® Infinity System, the LWD Plan Achromatic objectives with an ingenious Phase contrast concept deliver a remarkable image quality. 10X and 20X Phase Contrast objectives are an...
Open the catalog to page 2AE2000 ROUTINE LIVE CELL MICROSCOPE SOLUTION
Open the catalog to page 3THE MECHANICS STAND & STAGE | EYEPIECE TUBES
Open the catalog to page 4INTRODUCTION THE MECHANICS THE OPTICS THE ILLUMINATION CONTRAST METHODS DOCUMENTATION SPECIFICATIONS IMPROVED ERGONOMY FOR EFFICIENT WORK Motic’s AE2000 models display smart functionality and ergonomics in all mechanical aspects. Elegant and robust, the microscope stand follows all needs for an intense daily use. The fixed stage plate with optional lateral extensions carries a glass or metal insert for quick overview and comfortable change of objectives. An optional x/y object guide for convenient sample examination under high magnifications is available. Focusing is done by a 4-fold...
Open the catalog to page 5THE OPTICS OBJECTIVES | EYEPIECES
Open the catalog to page 6INTRODUCTION THE MECHANICS THE OPTICS THE ILLUMINATION CONTRAST METHODS DOCUMENTATION SPECIFICATIONS SMART PHASE CONTRAST FOR DAILY ROUTINE WORK Motic’s new LWD Plan Achromatic objectives for inverted microscopes provide a clever concept for Phase contrast. One illumination ring (Ph1) covers the objective magnifications 10X, 20X and 40X. No need to move the Phase ring slider when changing the magnification. The optional 4X Phase lens requires Phase ring Ph0 and is dedicated to quick and efficient sample screening. An optimized multi-layer coating for improved contrast as well as carefully...
Open the catalog to page 7THE ILLUMINATION LIGHT SOURCES | LIGHT MEMORY FUNCTION
Open the catalog to page 8INTRODUCTION THE MECHANICS THE OPTICS THE ILLUMINATION CONTRAST METHODS DOCUMENTATION SPECIFICATIONS A POWERFUL AND FLEXIBLE ILLUMINATION CONCEPT To take profit of Motic’s improved optics, the illumination concept has to take care of power and quality. All stand versions of the AE2000 carry a Fixed-Koehler setup. The 30 Watt Halogen transmitted light source is standard and displays full interchangeability with 3 Watt LED modules of different color temperatures (4500K, 6000K). For higher illumination apertures, an LWD condenser with NA 0.5 can be implemented. The built-in IR-sensor activates...
Open the catalog to page 9CONTRAST METHODS PHASE CONTRAST
Open the catalog to page 10INTRODUCTION THE MECHANICS THE OPTICS THE ILLUMINATION CONTRAST METHODS DOCUMENTATION SPECIFICATIONS PHASE CONTRAST FOR UNSTAINED SAMPLES The standard configurations of the AE2000 already offer the full functionality of a microbiology workstation. Cell cultures in a petri dish or flask, but also other living (unstained) material like water samples from a pond require Phase Contrast to visualize internal structures from fungi, protozoans or algae, structures which are hardly visible by the Bright Field illumination, even if the condenser diaphragm is used perfectly. In Phase contrast,...
Open the catalog to page 11DOCUMENTATION STANDARD PHOTOMICROGRAPHY | DIGITAL DOCUMENTATION
Open the catalog to page 12INTRODUCTION THE MECHANICS THE OPTICS THE ILLUMINATION CONTRAST METHODS DOCUMENTATION SPECIFICATIONS REPRODUCIBLE DOCUMENTATION RESULTS WITH HIGH RELIABILITY Documentation is a key issue in every aspect of microscopy, with special importance in biomedical applications like microbiology. The AE2000 follows this requirement by traditional photomicrography or more flexible C-mount solutions. Traditional photomicrography requires a Trinocular version of the AE2000. This setup delivers high resolution images of small fields. Live images for presentation and discussion may be supplied by the...
Open the catalog to page 13SPECIFICATIONS AE 2000 STANDARD CONFIGURATION & OPTIONAL ACCESSORIES General Specifications Optical system Observation system Interpupilary distance (mm) Eyepieces Eyepieces diopter adjustment Optional Configuration CCIS® Swiveling 360° with 45° inclination 48-75 N-WF 10X/22 Crosshair 10mm/100 divisions Crossed double scale 10mm/100 divisions Trinocular light split Nosepiece Plan Achromat objectives Objective mounting thread RMS standard (W 4/5'' X 1/36'') Phase ring Size stage plate (mm) 20/80 Quadruple, side orientated 4X/0.10; Ph 10X/0.25; LWD Ph 20X/0.3; LWD 40X/0.5 Ph1 - universal...
Open the catalog to page 14SPECIFICATIONS AE2000 SCHEMATIC DIAGRAMS & SYSTEM DIAGRAM (units: mm) Phase stop Ph0 Phase stop Ph1 Attachable mechanical stage Eyepieces N-WF 10X/20 Eyepieces N-WF 12.5X/18 Eyepieces N-WF 15X/16 Blue filter Green interference filter Ground glass filter Didymium filter Filter slider 2.5X Photo Eyepiece Petri dish holder d=54 Centering telescope* Petri dish holder d=65 Binocular tube Petri dish holder d=35 Photo adapter (to be used with Photo eyepiece) Stage C-mount adapter 0.65x Metal stage insert C-mount adapter 0.5x Glass stage insert C-mount adapter 1x CCIS® Plan Achromat PL 4X CCIS®...
Open the catalog to page 15Canada | China | Germany | Spain | USA www.moticeurope.com EN | ES | FR | DE | IT | PT Motic Instruments Inc. (Canada) 130 - 4611 Viking Way. Richmond, BC V6V 2K9 Canada Tel: 1-877-977 4717 | Fax: 1-604-303 9043 Motic Deutschland GmbH (Germany) Christian-Kremp-Strasse 11, D-35578 Wetzlar, Germany Tel: 49-6441-210 010 Fax: 49-6441-210 0122 Motic Hong Kong Limited (Hong Kong) Rm 2907-8, Windsor House, 311 Gloucester Road, Causeway Bay, Hong Kong Tel: 852-2837 0888 | Fax: 852-2882 2792 Motic Spain, S.L.U. (Spain) Pol. Ind. Les Corts, C. Les Corts 12. 08349 Cabrera de Mar, Barcelona, Spain Tel:...
Open the catalog to page 16All Motic catalogs and technical brochures
-
Moticam S & T
8 Pages
-
Moticam Pro
8 Pages
-
New Moticam
20 Pages
-
GM 168
2 Pages
-
SMZ 161 / 171
18 Pages
-
SMZ 168
24 Pages
-
VIS 100/ 200
20 Pages
-
PSM 1000
8 Pages
-
AE 2000 MET
12 Pages
-
AE 2000
16 Pages
-
AE 30
16 Pages
-
BA 410
20 Pages
-
BA 310 POL
2 Pages
-
BA 310 MET
14 Pages
-
BA 310 E
6 Pages
-
BA 310
12 Pages
-
BA 210 E
4 Pages
-
GM-161/GM-171
12 Pages
-
BA310Pol
2 Pages
-
SMZ-171 BP(Fixed Arm)
2 Pages
-
BA210 Binocular
16 Pages
-
BA210 Binocular
12 Pages