Product Data Sheet Actuator LD3 LD3 features its compact design, which is suitable for various applications that require limited installation space, such as window or gate opener, adjustable seat tilting and medical devices. Features and Options Main applications: Industrial, Furniture, Home care, Medical Standard features: ● Input voltage: 12V DC / 24V DC ● Max. load: 1000N (Push / Pull) ● Max. static load: 2500N (Push / Pull) ● Max. speed at no load: 43.9 mm/sec (Typical value) ● Speed at full load: 5.5 mm/sec (Typical value @1000N Loaded) ● Stroke: 50 / 100 / 150 / 200 / 250 / 300mm ● Noise level: Please refer to Performance Data ● IP level: IP54 ● Preset limit switches ● Duty cycle: 25%, max. 1 min. continuous operation in 4 min. ● Operating ambient temperature: -25°C ~ +65°C ● Certified: CE Marking, Electromagnetic Compatibility Directive 2014/30/EU (for LD3 only) Options: ● Medical version (LD3M, compliance with EN 60601) ● Quiet version (LD3Q, noise level ≦55dB) ● Positioning signal feedback with Hall effect sensor x 1 ● Positioning signal feedback with Hall effect sensor x 2 ● Analog positioning feedback with Potentiometer (POT) ● IP level: IP65 ● C15 clamps can be used as different types of r
Open the catalog to page 1Performance Data Regular version (LD3) Gear Ratio * Typical Speed (mm/s) No Load Full Load * Typical Current (A) No Load Full Load Remarks: * The typical speed or typical current means the average value neither upper limit nor lower limit. The performance curves are made with typical val
Open the catalog to page 2Medical version (LD3M) Gear Ratio Full Load Full Load Remarks: * The typical speed or typical current means the average value neither upper limit nor lower limit. The performance curves are made with typical val
Open the catalog to page 3Quiet version (LD3Q) Gear Ratio * Typical Speed (mm/s) No Load Full Load Full Load Remarks: * The typical speed or typical current means the average value neither upper limit nor lower limit. The performance curves are made with typical values.
Open the catalog to page 4Dimensions Extended length (B) = Retracted length (A) + Stroke (S) Retracted length (A) Stroke (S) Standard or Hall sensor Front connector code Note: The dimension “A” is shown in page 4 & 5, as indicated in the figure below. ● Regular version (LD3) & Quiet version (LD3Q) - Basic, without positioning feedback - With dual Hall effect sensors Note: As an example in 0° orientation for rear connector.
Open the catalog to page 5- With potentiometer ● Medical version (LD3M) - Basic, without positioning feedback - With potentiometer Note: As an example in 0° orientation for rear conne
Open the catalog to page 6● Front connector 3: Spherical rod eye Front connector code Diameter of pivot without bushing (D) ● Rear connector 1: Zinc alloy clevis, 0° 3: Zinc alloy clevis, 90° Rear connector code 1, 3 Diameter of pivot without bushing (D) ø6.4, ø8, ø10
Open the catalog to page 7Wiring ● Basic, without positioning feedback Wire color Power wires Connect red wire to “Vdc +” & black wire to “Vdc -“ of DC power to extend the actuator. Switch the polarity of DC input to retract it. ● With potentiometer (POT) Wire color Power wires Descriptions Connect red wire to “Vdc +” & black wire to “Vdc -“ of DC power to extend the actuator. Switch the polarity of DC input to retract it. Input voltage 70V max. Potentiometer specification: - 10K ohm, 10 turns. - Total resistance tolerance ±5% Output voltage: Between 0 ~ Vin The potentiometer resistance according to different strokes...
Open the catalog to page 9● With Hall effect sensor x 1 Wire color Power wires Descriptions Connect red wire to “Vdc +” & black wire to “Vdc -“ of DC power to extend the actuator. Switch the polarity of DC input to retract it. Voltage input range: 3.5 ~ 20V Hall effect sensor resolution: Gear ratio 5:1 Hall output Resolution (pulses/mm) Output voltage of signal (DATA) = Vin Hall signal data: Vin ● With Hall effect sensor x 2 Wire color Power wires Descriptions Connect red wire to “Vdc +” & black wire to “Vdc -“ of DC power to extend the actuator. Switch the polarity of DC input to retract it. Voltage input range: 3.5...
Open the catalog to page 10Ordering Key Regular version Input voltage Gear type (Refer to Page 2) Motor and Spindle type Front connector (Refer to Page 7) 1: Drilled hole 3: Spherical rod eye 6: Plastic slot Rear connector (Refer to Page 7) 1: Zinc alloy clevis, 0° 3: Zinc alloy clevis, 90° Positioning feedback Blank: None HS1: Hall effect sensor x 1 HS2: Hall effect sensor x 2 POT: Potentiometer Blank: None M1: MB22 mounting bracket, Ø8mm x 1 M2: MB22 mounting bracket, Ø8mm x 2 Blank: None C: C15 clamp
Open the catalog to page 11Medical version Gear type (Refer to Page 3) Motor and Spindle type Front connector (Refer to Page 7) 1: Drilled hole 3: Spherical rod eye 6: Plastic slot Rear connector (Refer to Page 7) 1: Zinc alloy clevis, 0° 3: Zinc alloy clevis, 90° Positioning feedback Blank: None POT: Potentiometer Blank: None M1: MB22 mounting bracket x 1 M2: MB22 mounting bracket x 2 Blank: None C: C15 clamp
Open the catalog to page 12Quiet version Input voltage Gear type (Refer to Page 4) Motor and Spindle type Front connector (Refer to Page 7) 1: Drilled hole 3: Spherical rod eye 6: Plastic slot Rear connector (Refer to Page 7) 1: Zinc alloy clevis, 0° 3: Zinc alloy clevis, 90° Positioning feedback Blank: None HS1: Hall effect sensor x 1 HS2: Hall effect sensor x 2 POT: Potentiometer Blank: None M1: MB22 mounting bracket x 1 M2: MB22 mounting bracket x 2 Blank: None C: C15 clamp
Open the catalog to page 13Certifications Regular version LD3 actuator is compliant with the following regulations, in terms of the essential conformity requirements of EMC Directive of 2014/30/EU. Emission EN55014-1:2017+A11:2020 Terms of Use The user is responsible for application suitability of Moteck products. As ongoing improvement process continues, products listed on the Moteck website are subject to change without prior notice. Moteck reserves the right to terminate the sales or remove any product displayed on the website, or listed in its catalogues.