Instruments 2

Instruments 2
1 / 46 PagesView full catalog

Instruments 2

Product catalog summary
Introduction
Nieaf-Smitt, part of Wabtec Corporation, has been a leader in electrical instrumentation since 1900, focusing on reliable test and measuring equipment for energy efficiency and safety in the installation sector.
Product Portfolio
Nieaf-Smitt offers a variety of portable test and measuring equipment, including solar testers, installation testers, and power analyzers, designed for quality and dependability.
Quality and Environmental Standards
The company adheres to ISO 9001:2000 and ISO 14001 standards, emphasizing reliability, safety, and environmental consciousness.
Solar Testers
Products like the EazyPV and IRM100 comply with IEC 62446 standards, facilitating easy and effective solar installation testing.
Installation Testers
Models such as IRT-C, RCT-S, and Instaltest XE verify electrical installations according to international standards.
Power Analyzers
Devices like PHA 4400 and PQA 7700 analyze power quality and efficiency in electrical systems.
Calibration and Support Services
Nieaf-Smitt provides calibration and repair services, along with a helpdesk and online support resources.
Specifications and Features
Key specifications include voltage measurement up to 1000 VDC, current measurement up to 600 AAC/DC, and resistance measurement up to 20 kΩ. Devices comply with overvoltage categories CAT II 1000 V / CAT III 600 V and standard EN 61010-1.
Installation Testers
Testers like RCT-S, IRT-C, and Instaltest XE are designed for testing electrical installations according to European standards, featuring memory storage and PC data transfer interfaces.
Accessories
Various accessories, including adapter plugs and installation kits, enhance the functionality of testing devices.
Regulatory Compliance
Testers comply with international standards, ensuring safety and performance in electrical testing.
Specifications
Specifications include RCD trip current options, contact voltage measurement, and impedance tests, ensuring comprehensive testing capabilities.
AutoTest Feature
The AutoTest function allows for automatic testing, combining measurements, and setting limiting values for pass/fail indication.
Power Analyzers
PHA 4400 and PQA 7700 are used for power quality assessment, featuring harmonics analysis and voltage event evaluations, with software for data analysis and report generation.
Standards and Compliance
Compliance with standards like EN 50160 and EN 61000-4-30 ensures accurate power quality analysis.
PowerManager Software
The software supports data analysis and report generation, with features like customizable views and real-time monitoring.
System Requirements
Compatible with Windows operating systems, requiring a minimum of 512 MB memory and 25 MB available space.
Contact Information
Sales office contact details are provided for various countries.
See more

Catalog excerpts

Instruments 2-1

Nieaf-Smitt Installation Technology Test- & measuring equipment Solar testers • Installation testers • Power analyser

 Open the catalog to page 1
Instruments 2-3

Nieaf-Smitt Installation Technology Test- & measuring equipment

 Open the catalog to page 3
Instruments 2-4

Nieaf-Smitt Installation Technology Company NIF (Netherlands Instrumentation Factory, later to become Nieaf-Smitt) started in 1900 as one of the first companies in the world with the design and manufacturing of instrumentation for electrical values. Since then Nieaf-Smitt has served the ongoing upgrading, upscaling, modernization and technical refinement in the installation sectors. The complexity and diversity in the installation sectors demands the specialism that Nieaf-Smitt provides by offering reliable instrumentation securing the energy efficiency and safety demands installations and appliances....

 Open the catalog to page 4
Instruments 2-5

Solar testers IRT-C.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RCT-S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ELT-S.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ERT-S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 5
Instruments 2-6

Quality and safety are the drivers of our thinking and doing

 Open the catalog to page 6
Instruments 2-7

Overvoltage installation categories according IEC 61010-1 IV I Measurement category IV is for measurements performed at the source of the low-voltage installation Measurement category I is for measurements performed on circuits not directly connected to MAINS Service Ingang Measurement category III is for measurements performed in the building installation Measurement category II is for measurements performed on circuits directly connected to the low voltage installation CAT I Examples are measurements on circuits not derived from MAINS, and specially protected (internal) MAINS-derived circuits....

 Open the catalog to page 7
Instruments 2-8

Calibration, Instrumentsreparatie en support Calibration repair services • Calibration of all brands and types and measurement equipment • Repair of all Nieaf-Smitt equipment Calibration Nieaf-Smitt has a professional calibration center. All electrical measurement equipment can be calibrated (multimeters, current clamps, temperaturemeters, installation testers, power meters, safety testers, thermal cameras, etc.) After free registration, you will receive automatically an anual notice to have your instruments calibrated. This way you do not have to worry about the validity of the calibration of...

 Open the catalog to page 8
Instruments 2-9

To meet the demand in PV-quality checks, Nieaf-Smitt has developed measuring equipment for solar panels / The portfolio consists of a PV-installationtester, an irradiance tester and power-efficiency meters. ^SMITT" www.nieaf-smitt.com

 Open the catalog to page 9
Instruments 2-10

Test and measurement of solar PV-installations The production and use of renewable energy is stimulated by the European Union and via government incentives (e.g. through RES directives) and the prices for solar panels are dropping, leading to a growing number of solar panel installations. With this the demand for initial and periodic testing of the solar panels is growing. Site survey, installation and commissioning of solar installations demands attention to safety, sustainability, reliability and efficiency / output of the solar panel system. Several guidelines and legislation are applicable:...

 Open the catalog to page 10
Instruments 2-11

The new high specification IRM100 combines irradiance measurement with a hosts other features to enable solar PV and solar thermal contractors to carry out site surveys quickly and easily. The versatile device uses a precision PV cell sensor for the highly accurate irradiance measurement, displaying results in either W/m2 or BTU/h/ft2. The EazyPV and IRM100 testers include all of the necessary functions to measure the electrical safety and performance of PV systems as well as irradiance. Additionally the kit is suitable to conduct site surveys for potential installations; providing the information...

 Open the catalog to page 11
Instruments 2-12

The compact PV-installationtester with digital display is the quickest on the market. The EazyPV combines all PV electrical test functions required to meet IEC 62446 into one safe, easy-to-use, hand-held device. The addition of USB and wireless connectivity in combination with the IRM100, make the EazyPV the most versatile PV tester on the market. Features • Visual inspection: is the installation wired up correct? No damage to cables during installation? • Insulation resistance measurement (Riso) • Earth continuity measurement (Rpe) • PV string short circuit current (Isc) • PV string open circuit...

 Open the catalog to page 12
Instruments 2-13

Irradiance meter To determine the quality and efficiency of solar panels it is important to check the circumstances in which the measurements are done. Features • Irradiance • Temperature • Compass • Tilt Including • Temperature probes • Quickstart manual • Batteries • Conformity declaration • USB-cable • Software (PV Link) • Support CD-rom • Bag Specifications Functions Irradiance Display Temperature Display Tilt Display Connecting the EazyPV with the IRM100 The EazyPV and IRM100 includes all of the necessary equipment to measure the electrical safety and performance of PV systems as well as...

 Open the catalog to page 13
Instruments 2-14

Compact AC/DC current clamp adapter The compact current clamp adapter NI T38 is an easy to use solution for measuring high currents (AC+DC) in combination with a multimeter. The clamp adapter is compatible with the EazyPV solar PV-tester. Features • 4 mm connectors • 2 ranges 40 A and 400 A • Non-contact voltage detection • Compatible with EazyPV solar PV-tester • AC & DC • Manual • Batteries Specifications Functions Output voltage Output voltage Specifications Max. diameter geleider Overvoltage category

 Open the catalog to page 14
Instruments 2-15

True RMS current clamp with power measurement The NI 18 plus is a sturdy, high quality multifunctional True RMS current clamp. The clamp can measure up to 600 AAC/DC and 750 VAC / 1000 VDC. Other functionalities like temperature, power factor, power (Watt) and phase rotation complete the NI 18 plus as the most allround clamp in the range. Features • True RMS • Current AC/DC • Voltage AC/DC • Resistance • Continuity test • Resistance • Total harmonic distortion • Temperature • Inrush current • Power measurement • Power factor • Phase rotation • LCD backlight Specifications Functions Effective...

 Open the catalog to page 15
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.