URF1D_QB
8Pages

{{requestButtons}}

Catalog excerpts

URF1D_QB - 1

50W/75W/100W, wide input voltage, isolated &regulated single output DC-DC converter Patent Protection RoHS FEATURES • Wide range of input voltage : 66-160V • Efficiency up to 92% • Low no-load power • Isolation voltage 3000VDC • Operating temperature range:-40°C~+100°C • Input under-voltage protection, output over-voltage, over-current, short circuit, over-temperature protection • International standard: 1/4 brick • Meets requirements of UL60950 and railway standard EN50155 JRF1D_QB Series is a high performance product designed for the field of railway applications. Output power contains 50W/75W/I00W, no min. load requirement, wide input voltage 66-i60VDC, which allows the base plate temperature up to 100 C. Further product feathers include input under- voltage protection, output over-voltage protection, short circuit protection, over temperature protection, remote control and compensated, output voltage regulation functions. Meets the EN50T55 railway standard and JL/EN60950safety standards. Widely used in the railway system and associated equipment. Selection Guide Input Specifications Output Specifications MORNSUN GUANGZHOU SCIENCC & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

Open the catalog to page 1
URF1D_QB - 2

DC/DC Converter URF1D QB Series MORNSUN® Transient Recovery Time MORNSUN GUANGZHOU SCIENCC & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

Open the catalog to page 2
URF1D_QB - 3

Efficiency Curves Efficiency Vs input Voltage (Full Load) Efficiency Vs Output Load(Vin=110V) Thermal Curves Ambient temperature(°C) No Heatsink Natural Conve MORNSUN A MORNSUN GUANGZHOU SCIENCC & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

Open the catalog to page 3
URF1D_QB - 4

DC/DC Converter URF1D_QB Series URF1D24QB-75W Thermal Curves (Vin=110V) 70 No Heatsink Natural Convection Heatsink Natural Convection Output power(W) Output power(W) Ambient temperature(℃) 50 No Heatsink Natural Convection Heatsink Natural Convection Output power(W) Output power(W) Ambient temperature(℃) Ambient temperature(℃) Ambient temperature(℃) Sense of application and precautions 1. When Remote Sense is not used +Vo sens e+ Trim sens e0V The le ad as s ho rt as po ss ible Short at pin root Notes: 1) When remote sense is not used, make sure + Vo and Sense + are shorted, and that 0V and...

Open the catalog to page 4
URF1D_QB - 5

DC/DC Converter URF1D_QB Series Design Reference 1. Ripple & noise All the URF1D_QB-100W series have been tested according to the following recommended test circuit before leaving the factory (see Figure 1). Copper sheet C0 sens e-Vin Connect Oscillograph Probe (20MHz bandwidth) 2. Typical application If don’t use our company’s EMC models, please make sure the input of at least 33uF electrolytic capacitor in parallel to suppress the input terminal may produce surge voltage. If it is required to further reduce input and output ripple, properly increase the input & output of additional...

Open the catalog to page 5
URF1D_QB - 6

DC/DC ConverterURF1D_QB Series5. Thermal design The maximum operating temperature of base- plate TB is 100 °C, as long as the user's thermal system keeps TB <100 °C, the converter can deliver its full rated power. A power derating curve can be calculated for any heatsink that is attached to the base-plate of the converter. It is only necessary to determine the thermal resistance, Rth(B-A), of the chosen heatsink between the base-plate and the ambient air for a given airflow rate. This information is usually available from the heatsink vendor. The following formula can the be used...

Open the catalog to page 6
URF1D_QB - 7

DC/DC Converter URF1D QB Series MORNSUN®Dimensions and Recommended Layout (without heatsink)THIRD ANGLE PROJECTION •03.50 [00.138] Aluminum Baseplate Front view Function Function +Vin Trim Note: Mounting hole screwing torque: Max 0.4 N m Dimensions and Recommended Layout(with heatsink) 6-01.50 [0O.OS9] THIRD ANGLE PROJECTION Front View Note:Grid 2.54*2.54mm Bottom View Pin-Out Function Function +Vin Sense Note: MORNSUN GUANGZHOU SCI€NC€ & T6CHNOLOGY CO.,LTD. Mounting hole screwing torque: Max 0.4 N m 2014.12.09-A/1 Page 7 of 8MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the...

Open the catalog to page 7
URF1D_QB - 8

DC/DC Converter URF1D_QB Series Note 1. Packing Information please refer to 'Product Packing Information'. Packing bag number:58010113(without heatsink), 58010112(with heatsink); 2. Recommended used in more than 5% load, if the load is lower than 5%, then the ripple index of the product may exceed the specification, but does not affect the reliability of the product; 3. The max capacitive load should be tested within the input voltage range and under full load conditions; 4. If the customer tests EMC, suggest to take our EMC module FC-CX3D. If the customer needs to meet the performance...

Open the catalog to page 8

All MORNSUN Guangzhou Science & Technology Co. catalogs and technical brochures

  1. LSxx-K3BxxSS

    4 Pages

  2. L003-10Bxx

    4 Pages

  3. FC-F18D

    4 Pages

  4. FC-L01D

    5 Pages

  5. K12T-16A-P

    7 Pages

  6. LMF320-20BXX

    5 Pages

  7. FS-TD01D

    2 Pages

  8. QP12W08S-37

    4 Pages

  9. TD321SCAN

    5 Pages

  10. TD301DCANHE

    4 Pages

  11. LSxx-K3BxxSS

    4 Pages

  12. QA151M

    4 Pages

  13. E_XT-1WAR2

    4 Pages

  14. HK_S

    4 Pages

  15. TxxxxGP

    3 Pages

  16. TFxxxxN

    5 Pages

  17. TFxxxxGN

    3 Pages

  18. QA1201C-20

    4 Pages

  19. QA2401C-20

    4 Pages

  20. QA156D-24

    3 Pages

  21. QAxx1

    4 Pages

  22. QAW

    4 Pages

  23. QA01C

    4 Pages

  24. QA

    5 Pages

  25. QAxxxD

    4 Pages

  26. FT-BX1D

    4 Pages

  27. T1100L-F

    2 Pages

  28. TxxxxL

    3 Pages

  29. TxxxxHL

    6 Pages

  30. TW147HL

    5 Pages

  31. TSx01W-EX-xx

    4 Pages

  32. TSx00W-EX-xx

    4 Pages

  33. TSFx02W-EX

    4 Pages

  34. TRxxxPW-EX

    5 Pages

  35. TCxxxPW-EX

    4 Pages

  36. TAxxxW-EX-xx

    4 Pages

  37. TRxxxPW

    4 Pages

  38. TCxxxPW

    4 Pages

  39. TAxxxW-xx

    4 Pages

  40. TAx06W-xx

    3 Pages

  41. TAxxxPW

    5 Pages

  42. T1100(N)NS

    3 Pages

  43. TFWxxxN

    4 Pages

  44. T1100L

    2 Pages

  45. TRPxxxxxP

    5 Pages

  46. TxxxxP

    6 Pages

  47. TExxxxN

    6 Pages

  48. MCP100

    4 Pages

  49. FI-B03D

    3 Pages

  50. FC-xxxD

    4 Pages

  51. FC-B01D

    5 Pages

  52. FC-A01D

    5 Pages

  53. FC-L01DV1

    3 Pages

  54. FC-LX1D2

    8 Pages

  55. FC-LX1D

    8 Pages

  56. TD5(3)01MCAN

    5 Pages

  57. TDx01D485H-E

    4 Pages

  58. TDx01D485H-A

    4 Pages

  59. TDHx01D485H

    4 Pages

  60. TDx01D485H

    4 Pages

  61. TDx01D232H

    4 Pages

  62. VRB_ZP-6WR3

    5 Pages

  63. VRB_YMD-6WR3

    5 Pages

  64. VRA_YMD-6WR3

    5 Pages

  65. URB_MT-3WR3

    5 Pages

  66. F_XT-2WR2

    5 Pages

  67. IF_XT-1WR2

    4 Pages

  68. F_XT-1WR2

    5 Pages

  69. B_S-3WR2

    3 Pages

  70. F_S-3WR2

    4 Pages

  71. WRF_S-3WR2

    6 Pages

  72. WRE_S-3WR2

    6 Pages

  73. WRB_S-3WR2

    6 Pages

  74. WRA_S-3WR2

    6 Pages

  75. WRF_S-1WR2

    6 Pages

  76. WRE_S-1WR2

    6 Pages

  77. WRB_S-1WR2

    6 Pages

  78. WRA_S-1WR2

    6 Pages

  79. IF_S-2W

    3 Pages

  80. IB_S-2W

    3 Pages

  81. F_S-2WR2

    5 Pages

  82. E_S-2WR2

    5 Pages

  83. B_S-2WR2

    5 Pages

  84. A_S-2WR2

    5 Pages

  85. IF_S-1W

    4 Pages

  86. B_S-1WR2

    6 Pages

  87. H_S-2WR2

    5 Pages

  88. H_S-1WR2

    5 Pages

  89. LD20-10Bxx

    7 Pages

  90. LD10-20Bxx

    6 Pages

  91. LD12-20Bxx

    7 Pages

  92. LD05-23Bxx

    5 Pages

  93. LD03-10BxxR2

    5 Pages

  94. URA_LD-30WR3

    9 Pages

  95. VRB_LD-20WR3

    8 Pages

  96. VRB_LD-30WR3

    8 Pages

  97. VRA_LD-20WR3

    8 Pages

  98. VRB_LD-15WR2

    9 Pages

  99. VRA_LD-15WR2

    9 Pages

  100. VRB_LD-15WR3

    8 Pages

  101. B0550LD-1WR2

    4 Pages

  102. B0560LD-1WR2

    4 Pages

  103. VRB_LD-50W

    8 Pages

  104. LS03-16BxxSS

    5 Pages

  105. LS05-15BXXSS

    5 Pages

  106. LS01-15BXXSS

    5 Pages

  107. IB_LS-1W

    4 Pages

  108. URB_LD-20WR3

    8 Pages

  109. URA_LD-20WR3

    8 Pages

  110. URA_YMD-6WR3

    6 Pages

  111. URB1D_LD-20W

    8 Pages

  112. URB1D_LD-15W

    8 Pages

  113. URB1D_XD-10W

    5 Pages

  114. URB1D_YMD-6W

    5 Pages

  115. URB_LD-30WR3

    9 Pages

  116. URB_ZP-6WR3

    5 Pages

Archived catalogs

  1. A05_XT-1WR3

    4 Pages

  2. LHE05-20Bxx

    5 Pages

  3. TEMxxxxCN

    4 Pages

  4. TEMxxxxAN

    4 Pages

  5. TExxxxCN

    3 Pages

  6. TExxxxHN

    6 Pages

  7. TExxxxAN

    3 Pages

  8. MBP series

    7 Pages

  9. LN02-12Bxx

    5 Pages

  10. KC24RT

    5 Pages

  11. QC962-8A

    5 Pages

  12. QP12W05S-37

    3 Pages

  13. FC-CX3D

    4 Pages

  14. FC-CXXD

    5 Pages

  15. TDx02D232H

    3 Pages

  16. VRA_ZP-6WR3

    5 Pages

  17. IB_XT-1WR2

    4 Pages