DC/DC Converter URF1D_HB-150W Series 150W, wide input voltage, isolated & regulated single output DC-DC converter Patent Protection RoHS Wide input voltage range: 50-160V High efficiency up to 91% No-load power consumption as low as 3mA Isolation voltage 3000VDC Operating temperature range:-40℃~+100℃ Input under-voltage protection, output over-voltage, over-current, short circuit, over-temperature protection International standard: 1/2 brick Meets requirements of railway standard EN50155 URF1D_HB-150W (H) series is a high performance product designed for the field of railway applications. Output power up to 150W, no min load requirement, wide input voltage 50-160VDC, which allows the base plate operating temperature up to 100℃. Further product feathers include input under-voltage protection, output over-voltage protection, short circuit protection, over current protection, over temperature protection, remote control and compensated, output voltage regulation functions. Meets the EN50155 railway standard. Widely used in the railway system and associated equipment. Selection Guide Input Voltage (VDC) Output Voltage(VDC) Efficiency (%, Min./Typ) @ Full Load Output Current (mA)(Max./Min.) Note: *Exceeding the maximum input voltage may cause permanent damage. Input Specifications Item Operating Conditions Input Current (full load / no-load) Nominal input Reflected Ripple Current Nominal input Input impulse Voltage (1sec. max.) Under-voltage Shutdown Voltage Starting Voltage Start-up Time Input Filter Pi filter Module switch on Module switch off Ctrl connected to -Vin or low level (0-1.2VDC) Input current when switched off Ctrl psuspended or connected to TTL high level (3.5-12VDC) -- Note: * the voltage of Ctrl pin is relative to input pin -Vin. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of
Open the catalog to page 1DC/DC Converter URF1D_HB-150W Series Output Specifications Item Operating Conditions Output Voltage Accuracy Line Regulation Full load, the input voltage is from low to high Load Regulation Transient Recovery Time Transient Response Deviation 25% load step change Temperature Coefficient Full load Ripple & Noise * 20MHz bandwidth (with 10%-100% load) Output voltage Regulated range(Trim) Output voltage remote compensation(Sense) Over-voltage Protection Input voltage range Over-current Protection Short circuit Protection Nominal input Hiccup, continuous, self-recovery Note: * The measuring method...
Open the catalog to page 2DC/DC Converter Physical Specifications Efficiency Curves Efficiency Vs Input Voltage (Full Load) Input Voltage(V) Efficiency Vs Output Load(Vin=l 10V) Oulput Current Percentages Temperature Derating Curve URF1D12HB-150W Thermal Curves (Vin=l 10V) Nalurd Convection Ambient temperature('C) Natural Convection Ambient temperalureCC) MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO..LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 3DC/DC Converter URF1D_HB-150W Series Sense of application and precautions 1. When Remote Sense is not used +Vo sens e+ Trim sens e0V The le ad as s ho rt as po ss ible Short at pin root Notes: 1. When remote sense is not used, make sure + Vo and Sense + are shorted, and that 0V and Sense- are shorted as well; Keep the patterns between + Vo and Sense + and 0V and Sense- as short as possible. Avoid a looping pattern. If noise enters the loop, the operation of the power module will become unstable. 2. When Remote Sense is used A s far as po s sibl e u sin g t he twis te d pair +Vo sens e+ Trim sens...
Open the catalog to page 4DC/DC Converter URF1D_HB-150W Series Design Reference 1. Ripple & noise All the URF1D_QB-100W series have been tested according to the following recommended test circuit before leaving the factory (see Fig. 2),Ripple & noise tested according to Fig. 3 Copp er sh eet C0 Trim sense - Con nect Osci llogr aph Probe (20MH z ba ndwidth ) Fig. 3 Note: Capacitive value C1:1µF/50V; C2:10µF/35V. 2. Typical application If not using our Mornsun’s EMC recommended circuit, please ensure an 100μF electrolytic capacitors in parallel with the input, which used to suppress the surge voltage come from the input...
Open the catalog to page 5DC/DC Converter URF1D_HB-150W Series Element model Recommended value Choose according to actual input current EMC solution-recommended circuit PCB layout 4. Thermal design The maximum operating temperature of base- plate TB is 100 ℃, as long as the user's thermal system keeps TB <100 ℃, the converter can deliver its full rated power. A power derating curve can be calculated for any heatsink that is attached to the base-plate of the converter. It is only necessary to determine the thermal resistance, Rth(B-A), of the chosen heatsink between the base-plate and the ambient air for a given airflow...
Open the catalog to page 6DC/DC Converter MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 7DC/DC Converter Dimensions (With heatsink) THIRD ANGLE PROJECTION ^} Mounting hole screwing torque: Max 0.4 N-m 1. Packing information please refer to Product Packing Information which can be downloaded from wwwmornsun-power.com, Packing bag number:58200069(without heatsink)» 58200061 (with heatsink); 2. The max capacitive load should be tested within the input voltage range and under full load conditions; 3. Recommends that customers plus silicone film or thermal grease between the module and the heatsink. In order to ensure good heat 4. Unless otherwise specified, parameters in this datasheet...
Open the catalog to page 892 Pages
77 Pages
24 Pages
4 Pages
4 Pages
4 Pages
5 Pages
7 Pages
4 Pages
6 Pages
6 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
3 Pages
5 Pages
5 Pages
5 Pages
2 Pages
4 Pages
5 Pages
4 Pages
3 Pages
4 Pages
4 Pages
4 Pages
3 Pages
6 Pages
6 Pages
4 Pages
5 Pages
5 Pages
5 Pages
5 Pages
6 Pages
4 Pages
7 Pages
8 Pages
8 Pages
7 Pages
8 Pages
2 Pages
6 Pages
4 Pages
3 Pages
5 Pages
3 Pages
4 Pages
4 Pages
3 Pages
4 Pages
4 Pages
4 Pages
5 Pages
4 Pages
4 Pages
4 Pages
2 Pages
3 Pages
6 Pages
5 Pages
4 Pages
4 Pages
4 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
5 Pages
3 Pages
4 Pages
2 Pages
5 Pages
6 Pages
6 Pages
4 Pages
5 Pages
3 Pages
4 Pages
5 Pages
5 Pages
3 Pages
8 Pages
8 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
4 Pages
5 Pages
3 Pages
4 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
3 Pages
3 Pages
5 Pages
5 Pages
5 Pages
5 Pages
4 Pages
5 Pages
6 Pages
5 Pages
5 Pages
7 Pages
6 Pages
7 Pages
5 Pages
5 Pages
9 Pages
8 Pages
8 Pages
8 Pages
9 Pages
9 Pages
8 Pages
4 Pages
4 Pages
8 Pages
5 Pages
5 Pages
5 Pages
4 Pages
8 Pages
8 Pages
6 Pages
6 Pages
4 Pages
7 Pages
8 Pages
8 Pages
5 Pages
5 Pages
9 Pages
8 Pages
9 Pages
9 Pages
5 Pages
2 Pages
2 Pages
3 Pages
4 Pages
3 Pages
2 Pages
5 Pages
4 Pages
3 Pages
5 Pages
5 Pages
3 Pages
5 Pages
3 Pages
5 Pages
5 Pages
3 Pages
4 Pages
4 Pages
7 Pages
6 Pages
3 Pages
3 Pages
4 Pages
4 Pages
5 Pages
4 Pages