DC/DC Converter URB1D_LD-15W & URB1D_LD-20W Series 15W&20W,Ultra wide input isolated & regulated DC/DC converter Wide input voltage range (4:1) High efficiency up to 89% Isolation voltage :1.5K VDC Operating temperature range: -40℃ to +85℃ Output short circuit(automatic recovery), over-current, over–voltage protection Six-sided metal shielding package International standard pin-out Reverse voltage protection available with A2S(Chassis mounting) or A4S(DIN-Rail mounting) EN60950 approval Patent Protection RoHS URB1D_LD-15W & URB1D_LD-20W series Wide input voltage range is 40-160VDC. It is suitable for 72 V, 96 V, 110 V standard input of the bus voltage, single output and 1500VDC isolation, over current, over voltage and short-circuit protection. It offers good EMC performance, meet EN60950 standards. All models are particularly suited to railway etc. Selection Guide Efficiency (%,Min/Typ.) @ Full Load Nominal (Range) Output Output Voltage (VDC) 3.3 Output Current (mA)(Max./Min.) Note: ①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mounting,with suffix “A4S” are DIN-Rail mounting, for example URB1D05LD-20WHA2S is chassis mounting of with heat sink,URB1D05LD-20WA4S is DIN-Rail mounting of without heat sink;If the application has a higher requirement for heat dissipation, you can choose modules with heat sink; ②Absolute maximum rating without damage on the converter, but it isn't recommended; ③The efficiency of A2S (wiring type) and A4S (rail type) products is 2% lower than the above-mentioned value due to the reverse connection protection for input; Input Specifications Item Input Current (full load / no-load) Operating Conditions Reflected Ripple Current Input impulse Voltage (1sec. max.) Starting Voltage Start-up Time Nominal input& constant resistance load Input Filter MORNSUN Guangzhou Science & Technology Co., Ltd. reserves

Open the catalog to page 1
URB1D_LD-20W / 20watt / (4:1) 40~160vdc / railway application - 2

DC/DC Converter URB1D_LD-15W & URB1D_LD-20W Series Module switch on Ctrl suspended or connected to TTL high level (2.5-12VDC) Ctrl pin connected to GND or low level (0-1.2VDC) Input current when switched off Note: * the voltage of Ctrl pin is relative to input pin GND. Output Specifications Item Operating Conditions Voltage Accuracy Line Regulation Full load, the input voltage is from low voltage to high voltage Load Regulation Transient Recovery Time 25% load step change Transient Response Deviation Temperature Drift Coefficient Full load Ripple & Noise * Output Voltage Range(Trim) Output...

Open the catalog to page 2
URB1D_LD-20W / 20watt / (4:1) 40~160vdc / railway application - 3

DC/DC Converter Output Current Percentage (%) Design Reference All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery If it is reauired to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or select capacitors of low eauivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product, MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final...

Open the catalog to page 3
URB1D_LD-20W / 20watt / (4:1) 40~160vdc / railway application - 4

DC/DC Converter URB1D_LD-15W & URB1D_LD-20W Series Vout(VDC) 2. EMC module solution-recommended circuit Parameter description Choose according to actual input current 100µF/200V Trim application & Trim resistance +Vot Calculation formula of Trim resistance: Trim down Application circuit for TRIM (Part in broken line is the interior of models) Note: Leave open if not used. RT: Resistance of Trim. a: User-defined parameter, no actual meanings. 4. The product does not support output in parallel with power per liter or hot-plug use 5. For more information please find the application notes on...

Open the catalog to page 4
URB1D_LD-20W / 20watt / (4:1) 40~160vdc / railway application - 5

DC/DC Converter Dimensions and Recommended Layout(without heatsink) Front View Unit :mm[inch] THIRD ANGLE PROJECTION-^ [Sj Unit :mm[inch] If use heatsinks,make sure there is enough space for a special size in ther above graph MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interp

Open the catalog to page 5
URB1D_LD-20W / 20watt / (4:1) 40~160vdc / railway application - 6

DC/DC Converter A2S Wiring Package Dimensions(without heatsink) THIRD ANGLE PROJECTION XLED lamp Fronit View MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

Open the catalog to page 6
URB1D_LD-20W / 20watt / (4:1) 40~160vdc / railway application - 7

DC/DC Converter A4S Rail Package Dimensions(without heatsink) THIRD ANGLE PROJECTION ^ XLED lamp MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

Open the catalog to page 7
URB1D_LD-20W / 20watt / (4:1) 40~160vdc / railway application - 8

DC/DC Converter URB1D_LD-15W & URB1D_LD-20W Series Notes: 1. Packing Information please refer to 'Product Packing Information'. The Packing bag number of Horizontal package: 58200024(without heatsink),58200051(with heatsink), the Packing bag number of A2S/ A4S package: 58220022; 2. Recommended used in more than 5% load, if the load is lower than 5%, then the ripple index of the product may exceed the specification, but does not affect the reliability of the product; 3. The max. capacitive load should be tested within the input voltage range and under full load conditions; 4. Unless...

Open the catalog to page 8

All MORNSUN Guangzhou Science & Technology Co. catalogs and technical brochures

  1. LSxx-K3BxxSS

    4 Pages

  2. L003-10Bxx

    4 Pages

  3. FC-F18D

    4 Pages

  4. FC-L01D

    5 Pages

  5. K12T-16A-P

    7 Pages

  6. LMF320-20BXX

    5 Pages

  7. FS-TD01D

    2 Pages

  8. QP12W08S-37

    4 Pages

  9. TD321SCAN

    5 Pages

  10. TD301DCANHE

    4 Pages

  11. LSxx-K3BxxSS

    4 Pages

  12. QA151M

    4 Pages

  13. E_XT-1WAR2

    4 Pages

  14. URF1D_QB

    8 Pages

  15. HK_S

    4 Pages

  16. TxxxxGP

    3 Pages

  17. TFxxxxN

    5 Pages

  18. TFxxxxGN

    3 Pages

  19. QA1201C-20

    4 Pages

  20. QA2401C-20

    4 Pages

  21. QA156D-24

    3 Pages

  22. QAxx1

    4 Pages

  23. QAW

    4 Pages

  24. QA01C

    4 Pages

  25. QA

    5 Pages

  26. QAxxxD

    4 Pages

  27. FT-BX1D

    4 Pages

  28. T1100L-F

    2 Pages

  29. TxxxxL

    3 Pages

  30. TxxxxHL

    6 Pages

  31. TW147HL

    5 Pages

  32. TSx01W-EX-xx

    4 Pages

  33. TSx00W-EX-xx

    4 Pages

  34. TSFx02W-EX

    4 Pages

  35. TRxxxPW-EX

    5 Pages

  36. TCxxxPW-EX

    4 Pages

  37. TAxxxW-EX-xx

    4 Pages

  38. TRxxxPW

    4 Pages

  39. TCxxxPW

    4 Pages

  40. TAxxxW-xx

    4 Pages

  41. TAx06W-xx

    3 Pages

  42. TAxxxPW

    5 Pages

  43. T1100(N)NS

    3 Pages

  44. TFWxxxN

    4 Pages

  45. T1100L

    2 Pages

  46. TRPxxxxxP

    5 Pages

  47. TxxxxP

    6 Pages

  48. TExxxxN

    6 Pages

  49. MCP100

    4 Pages

  50. FI-B03D

    3 Pages

  51. FC-xxxD

    4 Pages

  52. FC-B01D

    5 Pages

  53. FC-A01D

    5 Pages

  54. FC-L01DV1

    3 Pages

  55. FC-LX1D2

    8 Pages

  56. FC-LX1D

    8 Pages

  57. TD5(3)01MCAN

    5 Pages

  58. TDx01D485H-E

    4 Pages

  59. TDx01D485H-A

    4 Pages

  60. TDHx01D485H

    4 Pages

  61. TDx01D485H

    4 Pages

  62. TDx01D232H

    4 Pages

  63. VRB_ZP-6WR3

    5 Pages

  64. VRB_YMD-6WR3

    5 Pages

  65. VRA_YMD-6WR3

    5 Pages

  66. URB_MT-3WR3

    5 Pages

  67. F_XT-2WR2

    5 Pages

  68. IF_XT-1WR2

    4 Pages

  69. F_XT-1WR2

    5 Pages

  70. B_S-3WR2

    3 Pages

  71. F_S-3WR2

    4 Pages

  72. WRF_S-3WR2

    6 Pages

  73. WRE_S-3WR2

    6 Pages

  74. WRB_S-3WR2

    6 Pages

  75. WRA_S-3WR2

    6 Pages

  76. WRF_S-1WR2

    6 Pages

  77. WRE_S-1WR2

    6 Pages

  78. WRB_S-1WR2

    6 Pages

  79. WRA_S-1WR2

    6 Pages

  80. IF_S-2W

    3 Pages

  81. IB_S-2W

    3 Pages

  82. F_S-2WR2

    5 Pages

  83. E_S-2WR2

    5 Pages

  84. B_S-2WR2

    5 Pages

  85. A_S-2WR2

    5 Pages

  86. IF_S-1W

    4 Pages

  87. B_S-1WR2

    6 Pages

  88. H_S-2WR2

    5 Pages

  89. H_S-1WR2

    5 Pages

  90. LD20-10Bxx

    7 Pages

  91. LD10-20Bxx

    6 Pages

  92. LD12-20Bxx

    7 Pages

  93. LD05-23Bxx

    5 Pages

  94. LD03-10BxxR2

    5 Pages

  95. URA_LD-30WR3

    9 Pages

  96. VRB_LD-20WR3

    8 Pages

  97. VRB_LD-30WR3

    8 Pages

  98. VRA_LD-20WR3

    8 Pages

  99. VRB_LD-15WR2

    9 Pages

  100. VRA_LD-15WR2

    9 Pages

  101. VRB_LD-15WR3

    8 Pages

  102. B0550LD-1WR2

    4 Pages

  103. B0560LD-1WR2

    4 Pages

  104. VRB_LD-50W

    8 Pages

  105. LS03-16BxxSS

    5 Pages

  106. LS05-15BXXSS

    5 Pages

  107. LS01-15BXXSS

    5 Pages

  108. IB_LS-1W

    4 Pages

  109. URB_LD-20WR3

    8 Pages

  110. URA_LD-20WR3

    8 Pages

  111. URA_YMD-6WR3

    6 Pages

  112. URB1D_LD-20W

    8 Pages

  113. URB1D_LD-15W

    8 Pages

  114. URB1D_XD-10W

    5 Pages

  115. URB1D_YMD-6W

    5 Pages

  116. URB_LD-30WR3

    9 Pages

  117. URB_ZP-6WR3

    5 Pages

Archived catalogs

  1. A05_XT-1WR3

    4 Pages

  2. LHE05-20Bxx

    5 Pages

  3. TEMxxxxCN

    4 Pages

  4. TEMxxxxAN

    4 Pages

  5. TExxxxCN

    3 Pages

  6. TExxxxHN

    6 Pages

  7. TExxxxAN

    3 Pages

  8. MBP series

    7 Pages

  9. LN02-12Bxx

    5 Pages

  10. KC24RT

    5 Pages

  11. QC962-8A

    5 Pages

  12. QP12W05S-37

    3 Pages

  13. FC-CX3D

    4 Pages

  14. FC-CXXD

    5 Pages

  15. TDx02D232H

    3 Pages

  16. VRA_ZP-6WR3

    5 Pages

  17. IB_XT-1WR2

    4 Pages