Catalog excerpts
DC/DC Converter URA_ZP-6WR3 & URB_ZP-6WR3 Series 6W,Ultra wide input, isolated & regulated dual/ single output, DIP package, DC-DC converter Patent Protection RoHS Wide range of input voltage (4:1) Efficiency up to 88% No-load power consumption as low as 0.12W Isolation voltage :1500VDC Operating temperature range: -40℃ to +85℃ Input under-voltage protection, short circuit , over-voltage & Over-current protection output Meet CISPR22/EN55022 CLASS A International standard pin-out Meet UL60950 , EN60950 and IEC60950 URA_ZP-6WR & URB_ZP-6WR3 series products are of 6W output power, extremely wide range of voltage input of 9-36VDC, 18-75VDC, isolation voltage of 1500VDC, output over-voltage protection and output short circuit protection with the bare component in compliance with CISPR22/EN55022 CLASS A; these products are widely used in fields such as industrial control, electric power, instruments and communication. Selection Guide Input Voltage (VDC) Certification Nominal (Range) Output Voltage Output Current (mA) (Max./Min.) (VDC) Efficiency (%,Min./Typ.) @ Full Load Notes: 1 Absolute maximum rating without damage on the converter, but it isn't recommended; 2 Efficiency is measured In nominal input voltage and rated output load; 3 The capacitive loads of positive and negative outputs are identical. Input Specifications Item Input Current (full load / no-load) Operating Conditions Reflected Ripple Current Input impulse Voltage (1sec. max.) MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the
Open the catalog to page 1DC/DC Converter URA_ZP-6WR3 & URB_ZP-6WR3 Series MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 2Product Characteristic Curve Temperature Derating Curve Efficiency Vs Input Voltage (Full Load) Safe Operating Area Operating TemperatureCC) Input Voltage(V) MORNSUN GUANGZHOU SCIGNCG & TGCHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 3DC/DC ConverterURA_ZP-6WR3 & URB_ZP-6WR3 SeriesDesign Reference 1. Typical application All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery. If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product. EMC solution-recommended circuit PCB layout4. For more information please find the application notes on...
Open the catalog to page 4DC/DC ConverterURA_ZP-6WR3 & URB_ZP-6WR3 SeriesDimensions and Recommended Layout 1. Packing Information please refer to 'Product Packing Information'. Packing bag number: 58210008; 2. The unbalance degree of the recommended dual output module load: < 5%; if the degree exceeds ±5%, then the product performances cannot be guaranteed to comply with all the performance indicators in the manual, and please directly contact our technicians for specific information; 3. The max. capacitive load should be tested within the input voltage range and under full load conditions; 4. Unless otherwise...
Open the catalog to page 5All MORNSUN Guangzhou Science & Technology Co. catalogs and technical brochures
-
MORNSUN Product Catalogue
92 Pages
-
MORNSUN Product Catalogue (2021)
77 Pages
-
MORNSUN AC DC LMF1000
24 Pages
-
LSxx-K3BxxSS
4 Pages
-
L003-10Bxx
4 Pages
-
FC-F18D
4 Pages
-
FC-L01D
5 Pages
-
K12T-16A-P
7 Pages
-
AC/DC Converter LO10-13Bxx
4 Pages
-
AC/DC Converter LS05-13BxxR3
6 Pages
-
AC/DC Converter LS03-13BxxR3
6 Pages
-
AC/DC Converter LD20-23BxxR2
5 Pages
-
AC/DC Converter LD15-23BxxR2
5 Pages
-
AC/DC Converter LD10-23BxxR2
5 Pages
-
AC/DC Converter LD05-23BxxR2
5 Pages
-
AC/DC Converter LD03-23BxxR2
5 Pages
-
AC/DC Converter PVA150-27Bxx
3 Pages
-
LMF320-20BXX
5 Pages
-
IGBT Driver QC962-8A
5 Pages
-
IGBT Driver QP12W08S-37
5 Pages
-
FS-TD01D
2 Pages
-
QP12W08S-37
4 Pages
-
TD321SCAN
5 Pages
-
TD301DCANHE
4 Pages
-
CF0505XT-1WR3
3 Pages
-
IB05_XT-W75R3
4 Pages
-
LSxx-K3BxxSS
4 Pages
-
QA151M
4 Pages
-
LH40-10D0524-12
3 Pages
-
LDE15-20B03A2S
6 Pages
-
LS05-26BxxSS(-F)
6 Pages
-
E_XT-1WAR2
4 Pages
-
TD5(3)21D485H-E Series
5 Pages
-
TD5(3)21D485H-A Series
5 Pages
-
TD5(3)21D485H Series
5 Pages
-
TD5(3)21D485 Series
5 Pages
-
100W DC/DC converter
6 Pages
-
K78xx-1000R3(L) Series
4 Pages
-
URB1D_YMD-6WR3
7 Pages
-
URF1D_HB-150W
8 Pages
-
URF1D_QB
8 Pages
-
railway power
7 Pages
-
Railway power URB1D_LD-20WR3
8 Pages
-
FL2D-xx-xxx Series
2 Pages
-
LB(05-25)-10BxxLT
6 Pages
-
HK_S
4 Pages
-
TxxxxGP
3 Pages
-
TFxxxxN
5 Pages
-
TFxxxxGN
3 Pages
-
QA1201C-20
4 Pages
-
QA2401C-20
4 Pages
-
QA156D-24
3 Pages
-
QAxx1
4 Pages
-
QAW
4 Pages
-
QA01C
4 Pages
-
QA
5 Pages
-
QAxxxD
4 Pages
-
CF0505XT-1WR2
4 Pages
-
FT-BX1D
4 Pages
-
T1100L-F
2 Pages
-
TxxxxL
3 Pages
-
TxxxxHL
6 Pages
-
TW147HL
5 Pages
-
TSx01W-EX-xx
4 Pages
-
TSx00W-EX-xx
4 Pages
-
TSFx02W-EX
4 Pages
-
TRxxxPW-EX
5 Pages
-
TCxxxPW-EX
4 Pages
-
TAxxxW-EX-xx
4 Pages
-
TAF1xxW-EX-xx
4 Pages
-
TRxxxPW
4 Pages
-
TCxxxPW
4 Pages
-
TAxxxW-xx
4 Pages
-
TAx06W-xx
3 Pages
-
TAxxxPW
5 Pages
-
T1100(N)NS
3 Pages
-
TFWxxxN
4 Pages
-
T1100L
2 Pages
-
TRPxxxxxP
5 Pages
-
TxxxxP
6 Pages
-
TExxxxN
6 Pages
-
MCP100
4 Pages
-
LM30-00J0512-03E
5 Pages
-
FI-B03D
3 Pages
-
FC-xxxD
4 Pages
-
FC-B01D
5 Pages
-
FC-A01D
5 Pages
-
FC-L01DV1
3 Pages
-
FC-LX1D2
8 Pages
-
FC-LX1D
8 Pages
-
TD5(3)01MCAN
5 Pages
-
TD5(3)01MCANFD
4 Pages
-
TDx01D485H-E
4 Pages
-
TDx01D485H-A
4 Pages
-
TDHx01D485H
4 Pages
-
TDx01D485H
4 Pages
-
TDx01D232H
4 Pages
-
VRB_YMD-10WR3
5 Pages
-
VRB_ZP-6WR3
5 Pages
-
VRB_YMD-6WR3
5 Pages
-
VRA_YMD-6WR3
5 Pages
-
URB_MT-3WR3
5 Pages
-
F_XT-2WR2
5 Pages
-
IF_XT-1WR2
4 Pages
-
F_XT-1WR2
5 Pages
-
B_S-3WR2
3 Pages
-
F_S-3WR2
4 Pages
-
WRF_S-3WR2
6 Pages
-
WRE_S-3WR2
6 Pages
-
WRB_S-3WR2
6 Pages
-
WRA_S-3WR2
6 Pages
-
WRF_S-1WR2
6 Pages
-
WRE_S-1WR2
6 Pages
-
WRB_S-1WR2
6 Pages
-
WRA_S-1WR2
6 Pages
-
IF_S-2W
3 Pages
-
IB_S-2W
3 Pages
-
F_S-2WR2
5 Pages
-
E_S-2WR2
5 Pages
-
B_S-2WR2
5 Pages
-
A_S-2WR2
5 Pages
-
IF_S-1W
4 Pages
-
F_S-1WR2 E_S-1WR2
5 Pages
-
B_S-1WR2
6 Pages
-
H_S-2WR2
5 Pages
-
H_S-1WR2
5 Pages
-
LD20-10Bxx
7 Pages
-
LD10-20Bxx
6 Pages
-
LD12-20Bxx
7 Pages
-
LD05-23Bxx
5 Pages
-
LD03-10BxxR2
5 Pages
-
URA_LD-30WR3
9 Pages
-
VRB_LD-20WR3
8 Pages
-
VRB_LD-30WR3
8 Pages
-
VRA_LD-20WR3
8 Pages
-
VRB_LD-15WR2
9 Pages
-
VRA_LD-15WR2
9 Pages
-
VRB_LD-15WR3
8 Pages
-
B0550LD-1WR2
4 Pages
-
B0560LD-1WR2
4 Pages
-
VRB_LD-50W
8 Pages
-
LS03-16BxxSS
5 Pages
-
LS05-15BXXSS
5 Pages
-
LS01-15BXXSS
5 Pages
-
IB_LS-1W
4 Pages
-
URB_LD-20WR3
8 Pages
-
URA_LD-20WR3
8 Pages
-
URA_YMD-10WR3
6 Pages
-
URA_YMD-6WR3
6 Pages
-
Medical Power LD05-20BxxMU
4 Pages
-
84% High Efficiency LH15
7 Pages
-
URB1D_LD-20W
8 Pages
-
URB1D_LD-15W
8 Pages
-
URB1D_XD-10W
5 Pages
-
URB1D_YMD-6W
5 Pages
-
URB_LD-30WR3
9 Pages
-
URB1D_LD-20WR3
8 Pages
-
URB1D_LMD-15WR3
9 Pages
-
URB1D_LMD-20WR3
9 Pages
-
T1100L-F signal converter
2 Pages
-
T1100L signal converter
2 Pages
-
FS-A01D / Surge Suppressor
3 Pages
-
FT-BX1D / Pulse Suppressor
4 Pages
-
FI-B03D / EMI Filter
3 Pages
-
FL2D / Common Mode Filter
2 Pages
-
QC962-8A / IGBT driver
5 Pages
Archived catalogs
-
A05_XT-1WR3
4 Pages
-
LHE05-20Bxx
5 Pages
-
TEMxxxxCN
4 Pages
-
TEMxxxxAN
4 Pages
-
TExxxxCN
3 Pages
-
TExxxxHN
6 Pages
-
TExxxxAN
3 Pages
-
MBP series
7 Pages
-
LO10-26D0512-04L
4 Pages
-
LO20-10C0512-01
3 Pages
-
LN02-12Bxx
5 Pages
-
KC24RT
5 Pages
-
QC962-8A
5 Pages
-
QP12W05S-37
3 Pages
-
FC-CX3D
4 Pages
-
FC-CXXD
5 Pages
-
TDx02D232H
3 Pages
-
VRA_ZP-6WR3
5 Pages
-
IB_XT-1WR2
4 Pages
-
QP12W05S-37A / IGBT driver
3 Pages