Catalog excerpts
DC/DC ConverterURB1 D_LD-15W & URB1 D_LD-20W Series 15W & 20W, Ultra wide input isolated & regulated DC/DC converter C€ Patent Protection RoHS FEATURES • Ultra wide input voltage range (4:1) • High efficiency up to 89% • Isolation voltage : 1.5K VDC • Operating temperature range: -40°C to +85°C • Output short circuit(automatic recovery), over-current, over-voltage protection • Six-sided metal shielding package • International standard pin-out • Reverse voltage protection available with A2S(Chassis mounting) or A4S(35mm DIN-Rail mounting) • EN60950 approval URB1D_LD-15W & URB1D_LD-20Wseries Wide input voltage range is 40-160VDC. it is suitable for 72V, 11VVstandardinput of the bus voltage, single output and 1500VDC isolation, over current, over voltage and short-circuit protection. It offers good EMC performance, meet EN60950standards. All models are particularly suited to railway etc. ® Series with suffix "H" are heat sink mounting; series with suffix "A2S" are chassis mounting, with suffix "A4S" are DIN-Rail mounting, for example URB1D05LD-20WHA2S is chassis mounting of with heat sink, URB1D05LD-20WA4S is DIN-Rail mounting of without heat sink; If the application has a higher requirement for heat dissipation, you can choose modules with heat sink; (2 The minimum input voltage and starting voltage of A2S (wiring) and A4S (rail) Model are 1VDC higher than those of DIP package due to input reverse polarity protection function; (3 Absolute maximum rating without damage on the converter, but it isn't recommended; (4 The efficiency of A2S (wiring type) and A4S (rail type) products is 2% lower than the above-mentioned value due to the reverse connection protection for input. Input Specifications Item MORNSUN GUANGZHOU 5CIGNCG & TGCHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 1Note: * Ripple and noise tested with "parallel cable" method, please see DC-DC Converter Application Notesfor specific operation methods. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 2DC/DC ConverterURB1 D_LD-15W & URB1 D_LD-20W Series EMC Specifications Temperature Derating Curve Without heatsink Wth heatsink Temperature Derating Curve thout heatsink 60 Safe Operating Area 40 20 0 Safe Operating Area Operating Temperature(C) Efficiency Vs Output Load(Vin=Vin-nominal) Output Current Percentage (%) MORNSUN GUANGZHOU 5CIGNCG & TGCHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 3DC/DC ConverterURB1D LD-15W & URB1D LD-20W SeriesDesign Reference 1. Typical application All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery. If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product. 2. EMC module solution-recommended circuit Parameter description 3. Trim application & Trim resistance Calculation...
Open the catalog to page 4THIRD ANGLE PROJECTION Front View Unit :mm[inch] MORNSUN GUANGZHOU 5CIGNCG & TGCHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 5A2S Wiring Package Dimensions(without heatsink) A2S Wiring Package Dimensions(with heatsink) MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 6THIRD ANGLE PROJECTION Front View Unit: mm[inch] A4S Rail Package DimensionsCwith heatsink) THIRD ANGLE PROJECTION Front View Unit: mm[inch] 1. Packing Information please refer to 'Product Packing Information'. The Packing bag number of Horizontal package: 58200024(without heatsink),58200051(with heatsink), the Packing bag number of A2S/ A4S package: 58220022; 2. Recommend to use module with more than 5% load, if not, the ripple of the product may exceeds the specification, but does not affect the reliability of the product; 3. The maximum capacitive load offered were tested at input...
Open the catalog to page 7All MORNSUN Guangzhou Science & Technology Co. catalogs and technical brochures
-
MORNSUN Product Catalogue
92 Pages
-
MORNSUN Product Catalogue (2021)
77 Pages
-
MORNSUN AC DC LMF1000
24 Pages
-
LSxx-K3BxxSS
4 Pages
-
L003-10Bxx
4 Pages
-
FC-F18D
4 Pages
-
FC-L01D
5 Pages
-
K12T-16A-P
7 Pages
-
AC/DC Converter LO10-13Bxx
4 Pages
-
AC/DC Converter LS05-13BxxR3
6 Pages
-
AC/DC Converter LS03-13BxxR3
6 Pages
-
AC/DC Converter LD20-23BxxR2
5 Pages
-
AC/DC Converter LD15-23BxxR2
5 Pages
-
AC/DC Converter LD10-23BxxR2
5 Pages
-
AC/DC Converter LD05-23BxxR2
5 Pages
-
AC/DC Converter LD03-23BxxR2
5 Pages
-
AC/DC Converter PVA150-27Bxx
3 Pages
-
LMF320-20BXX
5 Pages
-
IGBT Driver QC962-8A
5 Pages
-
IGBT Driver QP12W08S-37
5 Pages
-
FS-TD01D
2 Pages
-
QP12W08S-37
4 Pages
-
TD321SCAN
5 Pages
-
TD301DCANHE
4 Pages
-
CF0505XT-1WR3
3 Pages
-
IB05_XT-W75R3
4 Pages
-
LSxx-K3BxxSS
4 Pages
-
QA151M
4 Pages
-
LH40-10D0524-12
3 Pages
-
LDE15-20B03A2S
6 Pages
-
LS05-26BxxSS(-F)
6 Pages
-
E_XT-1WAR2
4 Pages
-
TD5(3)21D485H-E Series
5 Pages
-
TD5(3)21D485H-A Series
5 Pages
-
TD5(3)21D485H Series
5 Pages
-
TD5(3)21D485 Series
5 Pages
-
100W DC/DC converter
6 Pages
-
K78xx-1000R3(L) Series
4 Pages
-
URB1D_YMD-6WR3
7 Pages
-
URF1D_HB-150W
8 Pages
-
URF1D_QB
8 Pages
-
Railway power URB1D_LD-20WR3
8 Pages
-
FL2D-xx-xxx Series
2 Pages
-
LB(05-25)-10BxxLT
6 Pages
-
HK_S
4 Pages
-
TxxxxGP
3 Pages
-
TFxxxxN
5 Pages
-
TFxxxxGN
3 Pages
-
QA1201C-20
4 Pages
-
QA2401C-20
4 Pages
-
QA156D-24
3 Pages
-
QAxx1
4 Pages
-
QAW
4 Pages
-
QA01C
4 Pages
-
QA
5 Pages
-
QAxxxD
4 Pages
-
CF0505XT-1WR2
4 Pages
-
FT-BX1D
4 Pages
-
T1100L-F
2 Pages
-
TxxxxL
3 Pages
-
TxxxxHL
6 Pages
-
TW147HL
5 Pages
-
TSx01W-EX-xx
4 Pages
-
TSx00W-EX-xx
4 Pages
-
TSFx02W-EX
4 Pages
-
TRxxxPW-EX
5 Pages
-
TCxxxPW-EX
4 Pages
-
TAxxxW-EX-xx
4 Pages
-
TAF1xxW-EX-xx
4 Pages
-
TRxxxPW
4 Pages
-
TCxxxPW
4 Pages
-
TAxxxW-xx
4 Pages
-
TAx06W-xx
3 Pages
-
TAxxxPW
5 Pages
-
T1100(N)NS
3 Pages
-
TFWxxxN
4 Pages
-
T1100L
2 Pages
-
TRPxxxxxP
5 Pages
-
TxxxxP
6 Pages
-
TExxxxN
6 Pages
-
MCP100
4 Pages
-
LM30-00J0512-03E
5 Pages
-
FI-B03D
3 Pages
-
FC-xxxD
4 Pages
-
FC-B01D
5 Pages
-
FC-A01D
5 Pages
-
FC-L01DV1
3 Pages
-
FC-LX1D2
8 Pages
-
FC-LX1D
8 Pages
-
TD5(3)01MCAN
5 Pages
-
TD5(3)01MCANFD
4 Pages
-
TDx01D485H-E
4 Pages
-
TDx01D485H-A
4 Pages
-
TDHx01D485H
4 Pages
-
TDx01D485H
4 Pages
-
TDx01D232H
4 Pages
-
VRB_YMD-10WR3
5 Pages
-
VRB_ZP-6WR3
5 Pages
-
VRB_YMD-6WR3
5 Pages
-
VRA_YMD-6WR3
5 Pages
-
URB_MT-3WR3
5 Pages
-
F_XT-2WR2
5 Pages
-
IF_XT-1WR2
4 Pages
-
F_XT-1WR2
5 Pages
-
B_S-3WR2
3 Pages
-
F_S-3WR2
4 Pages
-
WRF_S-3WR2
6 Pages
-
WRE_S-3WR2
6 Pages
-
WRB_S-3WR2
6 Pages
-
WRA_S-3WR2
6 Pages
-
WRF_S-1WR2
6 Pages
-
WRE_S-1WR2
6 Pages
-
WRB_S-1WR2
6 Pages
-
WRA_S-1WR2
6 Pages
-
IF_S-2W
3 Pages
-
IB_S-2W
3 Pages
-
F_S-2WR2
5 Pages
-
E_S-2WR2
5 Pages
-
B_S-2WR2
5 Pages
-
A_S-2WR2
5 Pages
-
IF_S-1W
4 Pages
-
F_S-1WR2 E_S-1WR2
5 Pages
-
B_S-1WR2
6 Pages
-
H_S-2WR2
5 Pages
-
H_S-1WR2
5 Pages
-
LD20-10Bxx
7 Pages
-
LD10-20Bxx
6 Pages
-
LD12-20Bxx
7 Pages
-
LD05-23Bxx
5 Pages
-
LD03-10BxxR2
5 Pages
-
URA_LD-30WR3
9 Pages
-
VRB_LD-20WR3
8 Pages
-
VRB_LD-30WR3
8 Pages
-
VRA_LD-20WR3
8 Pages
-
VRB_LD-15WR2
9 Pages
-
VRA_LD-15WR2
9 Pages
-
VRB_LD-15WR3
8 Pages
-
B0550LD-1WR2
4 Pages
-
B0560LD-1WR2
4 Pages
-
VRB_LD-50W
8 Pages
-
LS03-16BxxSS
5 Pages
-
LS05-15BXXSS
5 Pages
-
LS01-15BXXSS
5 Pages
-
IB_LS-1W
4 Pages
-
URB_LD-20WR3
8 Pages
-
URA_LD-20WR3
8 Pages
-
URA_YMD-10WR3
6 Pages
-
URA_YMD-6WR3
6 Pages
-
Medical Power LD05-20BxxMU
4 Pages
-
84% High Efficiency LH15
7 Pages
-
URB1D_LD-20W
8 Pages
-
URB1D_LD-15W
8 Pages
-
URB1D_XD-10W
5 Pages
-
URB1D_YMD-6W
5 Pages
-
URB_LD-30WR3
9 Pages
-
URB1D_LD-20WR3
8 Pages
-
URB1D_LMD-15WR3
9 Pages
-
URB1D_LMD-20WR3
9 Pages
-
URB_ZP-6WR3
5 Pages
-
T1100L-F signal converter
2 Pages
-
T1100L signal converter
2 Pages
-
FS-A01D / Surge Suppressor
3 Pages
-
FT-BX1D / Pulse Suppressor
4 Pages
-
FI-B03D / EMI Filter
3 Pages
-
FL2D / Common Mode Filter
2 Pages
-
QC962-8A / IGBT driver
5 Pages
Archived catalogs
-
A05_XT-1WR3
4 Pages
-
LHE05-20Bxx
5 Pages
-
TEMxxxxCN
4 Pages
-
TEMxxxxAN
4 Pages
-
TExxxxCN
3 Pages
-
TExxxxHN
6 Pages
-
TExxxxAN
3 Pages
-
MBP series
7 Pages
-
LO10-26D0512-04L
4 Pages
-
LO20-10C0512-01
3 Pages
-
LN02-12Bxx
5 Pages
-
KC24RT
5 Pages
-
QC962-8A
5 Pages
-
QP12W05S-37
3 Pages
-
FC-CX3D
4 Pages
-
FC-CXXD
5 Pages
-
TDx02D232H
3 Pages
-
VRA_ZP-6WR3
5 Pages
-
IB_XT-1WR2
4 Pages
-
QP12W05S-37A / IGBT driver