Catalog excerpts
AC/DC ConverterMBP Series 300 - 500W, 165 - 264VAC Input, Dual output AC/DC battery charging module power supply FEATURES • Low stand-by power consumption, • Maximum instantaneous power up to 702W (MBP500) • With charging function, the 24V/48V output Lead-acid battery can be charged, when system connected with battery, it can be used as uninterrupted power supply • With charge and discharge management, battery status display, battery activation, external communications and control functions • Output over-current, over-voltage protection • 2.5KVAC high isolation voltage • Industrial grade operating temperature: -40 C to +70 °C • Chassis mounting MBP Series are AC/DC battery charge power converter offered by Mornsun. It features wide Input voltage range, taking both DC and AC input voltage, output over-current, over-voifage protection, strong ability in adapting power grid. This product has power working status display and Intelligent charging function, it can used to charge the 24V/48V lead-acid battery, when AC is power-off, the battery can supply power to the load; it has battery activations and over discharge protection function, the activation maintenance of battery can be done manual or automatic through external signals. Designed specifically for distribution automation terminal (DTU / FTU). it is widely used in the power industry switch substations, power substation, RMU Intelligent Package Substation, Intelligent Switch Controller and other industries which need uninterrupted power supply. Output Specifications Item MORNSUN GUANGZHOU SCIGNCG & TGCHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 1AC/DC ConverterMBP Series Battery charge current Note: *When the ambient temperature exceeds 50 °C, it should be taken the cooling method of force air cooling or post cooling to ensure that the module shield temperature is not more than 80 C. MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 2MORNSUN Physical Specifications Principle block diagram MORNSUN MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 3AC/DC ConverterMBP SeriesPanel description 1 .Charging and operation indicator light 4.Battery under-voltage indicator light 7.Manual activation quit button 3.Battery activation indicator light 6.Manual activation start button 9.Manual battery quit button 10.Terminal MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Open the catalog to page 4AC/DC ConverterMBP Series 2.Wiring diagram Hi|h Battery Wiring Description: K1 K2 K3 are the contact points for the user's CPU and other control, R is the battery activated discharge resistance, load is the user's normal load, the battery is 24V or 48V battery pack. Terminal capacity is 300V/15A. The specific use please refer to the Using Manual instructions Manual Instruction 1. Power supply status indicator Charge, lights Green, Battery Charge indication, It lights when the battery is charging and off when the battery is discharging or activated. Discharge, lights Red, Battery Discharge...
Open the catalog to page 5AC/DC ConverterMBP Series the power automatic starting work to supply the load and charge the battery. When need to withdraw from activation halfway, can press the Manual activation quit button to withdraw from activation, or use the relay controlled by the CPU to make the power pin HG and VG in short circuit (not less than 0.5 seconds), then withdraw from activation in advance. Note: The activation function does not work when the power supply is not connected to the battery or the battery voltage is lower than the battery activation. 5. Application of activated discharge terminal RL Refer...
Open the catalog to page 6MBP SeriesDimensions and Recommended Layout THIRD ANGLE PROJECTION K$)tg Note: Unit: mm[inch] Wire range: 28-12 AWG Tightening torque: Max 0.4 N m General tolerances: ± 1.00[±0.039] Attention Matters in Application (1) Output please use wire that cross area is more than 2.5mm2, input terminal should add 10A/250VAC Fuse. (2) Please correct connection according to the wiring diagram, do not connect wrongly, battery output terminal is strictly prohibited to connect reversely, AC input terminal is strictly prohibited connected with other terminals wrong, otherwise will cause permanent damage to...
Open the catalog to page 7All MORNSUN Guangzhou Science & Technology Co. catalogs and technical brochures
-
MORNSUN Product Catalogue
92 Pages
-
MORNSUN Product Catalogue (2021)
77 Pages
-
MORNSUN AC DC LMF1000
24 Pages
-
LSxx-K3BxxSS
4 Pages
-
L003-10Bxx
4 Pages
-
FC-F18D
4 Pages
-
FC-L01D
5 Pages
-
K12T-16A-P
7 Pages
-
AC/DC Converter LO10-13Bxx
4 Pages
-
AC/DC Converter LS05-13BxxR3
6 Pages
-
AC/DC Converter LS03-13BxxR3
6 Pages
-
AC/DC Converter LD20-23BxxR2
5 Pages
-
AC/DC Converter LD15-23BxxR2
5 Pages
-
AC/DC Converter LD10-23BxxR2
5 Pages
-
AC/DC Converter LD05-23BxxR2
5 Pages
-
AC/DC Converter LD03-23BxxR2
5 Pages
-
AC/DC Converter PVA150-27Bxx
3 Pages
-
LMF320-20BXX
5 Pages
-
IGBT Driver QC962-8A
5 Pages
-
IGBT Driver QP12W08S-37
5 Pages
-
FS-TD01D
2 Pages
-
QP12W08S-37
4 Pages
-
TD321SCAN
5 Pages
-
TD301DCANHE
4 Pages
-
CF0505XT-1WR3
3 Pages
-
IB05_XT-W75R3
4 Pages
-
LSxx-K3BxxSS
4 Pages
-
QA151M
4 Pages
-
LH40-10D0524-12
3 Pages
-
LDE15-20B03A2S
6 Pages
-
LS05-26BxxSS(-F)
6 Pages
-
E_XT-1WAR2
4 Pages
-
TD5(3)21D485H-E Series
5 Pages
-
TD5(3)21D485H-A Series
5 Pages
-
TD5(3)21D485H Series
5 Pages
-
TD5(3)21D485 Series
5 Pages
-
100W DC/DC converter
6 Pages
-
K78xx-1000R3(L) Series
4 Pages
-
URB1D_YMD-6WR3
7 Pages
-
URF1D_HB-150W
8 Pages
-
URF1D_QB
8 Pages
-
railway power
7 Pages
-
Railway power URB1D_LD-20WR3
8 Pages
-
FL2D-xx-xxx Series
2 Pages
-
LB(05-25)-10BxxLT
6 Pages
-
HK_S
4 Pages
-
TxxxxGP
3 Pages
-
TFxxxxN
5 Pages
-
TFxxxxGN
3 Pages
-
QA1201C-20
4 Pages
-
QA2401C-20
4 Pages
-
QA156D-24
3 Pages
-
QAxx1
4 Pages
-
QAW
4 Pages
-
QA01C
4 Pages
-
QA
5 Pages
-
QAxxxD
4 Pages
-
CF0505XT-1WR2
4 Pages
-
FT-BX1D
4 Pages
-
T1100L-F
2 Pages
-
TxxxxL
3 Pages
-
TxxxxHL
6 Pages
-
TW147HL
5 Pages
-
TSx01W-EX-xx
4 Pages
-
TSx00W-EX-xx
4 Pages
-
TSFx02W-EX
4 Pages
-
TRxxxPW-EX
5 Pages
-
TCxxxPW-EX
4 Pages
-
TAxxxW-EX-xx
4 Pages
-
TAF1xxW-EX-xx
4 Pages
-
TRxxxPW
4 Pages
-
TCxxxPW
4 Pages
-
TAxxxW-xx
4 Pages
-
TAx06W-xx
3 Pages
-
TAxxxPW
5 Pages
-
T1100(N)NS
3 Pages
-
TFWxxxN
4 Pages
-
T1100L
2 Pages
-
TRPxxxxxP
5 Pages
-
TxxxxP
6 Pages
-
TExxxxN
6 Pages
-
MCP100
4 Pages
-
LM30-00J0512-03E
5 Pages
-
FI-B03D
3 Pages
-
FC-xxxD
4 Pages
-
FC-B01D
5 Pages
-
FC-A01D
5 Pages
-
FC-L01DV1
3 Pages
-
FC-LX1D2
8 Pages
-
FC-LX1D
8 Pages
-
TD5(3)01MCAN
5 Pages
-
TD5(3)01MCANFD
4 Pages
-
TDx01D485H-E
4 Pages
-
TDx01D485H-A
4 Pages
-
TDHx01D485H
4 Pages
-
TDx01D485H
4 Pages
-
TDx01D232H
4 Pages
-
VRB_YMD-10WR3
5 Pages
-
VRB_ZP-6WR3
5 Pages
-
VRB_YMD-6WR3
5 Pages
-
VRA_YMD-6WR3
5 Pages
-
URB_MT-3WR3
5 Pages
-
F_XT-2WR2
5 Pages
-
IF_XT-1WR2
4 Pages
-
F_XT-1WR2
5 Pages
-
B_S-3WR2
3 Pages
-
F_S-3WR2
4 Pages
-
WRF_S-3WR2
6 Pages
-
WRE_S-3WR2
6 Pages
-
WRB_S-3WR2
6 Pages
-
WRA_S-3WR2
6 Pages
-
WRF_S-1WR2
6 Pages
-
WRE_S-1WR2
6 Pages
-
WRB_S-1WR2
6 Pages
-
WRA_S-1WR2
6 Pages
-
IF_S-2W
3 Pages
-
IB_S-2W
3 Pages
-
F_S-2WR2
5 Pages
-
E_S-2WR2
5 Pages
-
B_S-2WR2
5 Pages
-
A_S-2WR2
5 Pages
-
IF_S-1W
4 Pages
-
F_S-1WR2 E_S-1WR2
5 Pages
-
B_S-1WR2
6 Pages
-
H_S-2WR2
5 Pages
-
H_S-1WR2
5 Pages
-
LD20-10Bxx
7 Pages
-
LD10-20Bxx
6 Pages
-
LD12-20Bxx
7 Pages
-
LD05-23Bxx
5 Pages
-
LD03-10BxxR2
5 Pages
-
URA_LD-30WR3
9 Pages
-
VRB_LD-20WR3
8 Pages
-
VRB_LD-30WR3
8 Pages
-
VRA_LD-20WR3
8 Pages
-
VRB_LD-15WR2
9 Pages
-
VRA_LD-15WR2
9 Pages
-
VRB_LD-15WR3
8 Pages
-
B0550LD-1WR2
4 Pages
-
B0560LD-1WR2
4 Pages
-
VRB_LD-50W
8 Pages
-
LS03-16BxxSS
5 Pages
-
LS05-15BXXSS
5 Pages
-
LS01-15BXXSS
5 Pages
-
IB_LS-1W
4 Pages
-
URB_LD-20WR3
8 Pages
-
URA_LD-20WR3
8 Pages
-
URA_YMD-10WR3
6 Pages
-
URA_YMD-6WR3
6 Pages
-
Medical Power LD05-20BxxMU
4 Pages
-
84% High Efficiency LH15
7 Pages
-
URB1D_LD-20W
8 Pages
-
URB1D_LD-15W
8 Pages
-
URB1D_XD-10W
5 Pages
-
URB1D_YMD-6W
5 Pages
-
URB_LD-30WR3
9 Pages
-
URB1D_LD-20WR3
8 Pages
-
URB1D_LMD-15WR3
9 Pages
-
URB1D_LMD-20WR3
9 Pages
-
URB_ZP-6WR3
5 Pages
-
T1100L-F signal converter
2 Pages
-
T1100L signal converter
2 Pages
-
FS-A01D / Surge Suppressor
3 Pages
-
FT-BX1D / Pulse Suppressor
4 Pages
-
FI-B03D / EMI Filter
3 Pages
-
FL2D / Common Mode Filter
2 Pages
-
QC962-8A / IGBT driver
5 Pages
Archived catalogs
-
A05_XT-1WR3
4 Pages
-
LHE05-20Bxx
5 Pages
-
TEMxxxxCN
4 Pages
-
TEMxxxxAN
4 Pages
-
TExxxxCN
3 Pages
-
TExxxxHN
6 Pages
-
TExxxxAN
3 Pages
-
LO10-26D0512-04L
4 Pages
-
LO20-10C0512-01
3 Pages
-
LN02-12Bxx
5 Pages
-
KC24RT
5 Pages
-
QC962-8A
5 Pages
-
QP12W05S-37
3 Pages
-
FC-CX3D
4 Pages
-
FC-CXXD
5 Pages
-
TDx02D232H
3 Pages
-
VRA_ZP-6WR3
5 Pages
-
IB_XT-1WR2
4 Pages
-
QP12W05S-37A / IGBT driver
3 Pages