MBP series
7Pages

{{requestButtons}}

Catalog excerpts

MBP series - 1

AC/DC ConverterMBP Series 300 - 500W, 165 - 264VAC Input, Dual output AC/DC battery charging module power supply FEATURES • Low stand-by power consumption, • Maximum instantaneous power up to 702W (MBP500) • With charging function, the 24V/48V output Lead-acid battery can be charged, when system connected with battery, it can be used as uninterrupted power supply • With charge and discharge management, battery status display, battery activation, external communications and control functions • Output over-current, over-voltage protection • 2.5KVAC high isolation voltage • Industrial grade operating temperature: -40 C to +70 °C • Chassis mounting MBP Series are AC/DC battery charge power converter offered by Mornsun. It features wide Input voltage range, taking both DC and AC input voltage, output over-current, over-voifage protection, strong ability in adapting power grid. This product has power working status display and Intelligent charging function, it can used to charge the 24V/48V lead-acid battery, when AC is power-off, the battery can supply power to the load; it has battery activations and over discharge protection function, the activation maintenance of battery can be done manual or automatic through external signals. Designed specifically for distribution automation terminal (DTU / FTU). it is widely used in the power industry switch substations, power substation, RMU Intelligent Package Substation, Intelligent Switch Controller and other industries which need uninterrupted power supply. Output Specifications Item MORNSUN GUANGZHOU SCIGNCG & TGCHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

Open the catalog to page 1
MBP series - 2

AC/DC ConverterMBP Series Battery charge current Note: *When the ambient temperature exceeds 50 °C, it should be taken the cooling method of force air cooling or post cooling to ensure that the module shield temperature is not more than 80 C. MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

Open the catalog to page 2
MBP series - 3

MORNSUN Physical Specifications Principle block diagram MORNSUN MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

Open the catalog to page 3
MBP series - 4

AC/DC ConverterMBP SeriesPanel description 1 .Charging and operation indicator light 4.Battery under-voltage indicator light 7.Manual activation quit button 3.Battery activation indicator light 6.Manual activation start button 9.Manual battery quit button 10.Terminal MORNSUN GUANGZHOU SCIENCE & TECHNOLOGY CO.,LTD. MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

Open the catalog to page 4
MBP series - 5

AC/DC ConverterMBP Series 2.Wiring diagram Hi|h Battery Wiring Description: K1 K2 K3 are the contact points for the user's CPU and other control, R is the battery activated discharge resistance, load is the user's normal load, the battery is 24V or 48V battery pack. Terminal capacity is 300V/15A. The specific use please refer to the Using Manual instructions Manual Instruction 1. Power supply status indicator Charge, lights Green, Battery Charge indication, It lights when the battery is charging and off when the battery is discharging or activated. Discharge, lights Red, Battery Discharge...

Open the catalog to page 5
MBP series - 6

AC/DC ConverterMBP Series the power automatic starting work to supply the load and charge the battery. When need to withdraw from activation halfway, can press the Manual activation quit button to withdraw from activation, or use the relay controlled by the CPU to make the power pin HG and VG in short circuit (not less than 0.5 seconds), then withdraw from activation in advance. Note: The activation function does not work when the power supply is not connected to the battery or the battery voltage is lower than the battery activation. 5. Application of activated discharge terminal RL Refer...

Open the catalog to page 6
MBP series - 7

MBP SeriesDimensions and Recommended Layout THIRD ANGLE PROJECTION K$)tg Note: Unit: mm[inch] Wire range: 28-12 AWG Tightening torque: Max 0.4 N m General tolerances: ± 1.00[±0.039] Attention Matters in Application (1) Output please use wire that cross area is more than 2.5mm2, input terminal should add 10A/250VAC Fuse. (2) Please correct connection according to the wiring diagram, do not connect wrongly, battery output terminal is strictly prohibited to connect reversely, AC input terminal is strictly prohibited connected with other terminals wrong, otherwise will cause permanent damage to...

Open the catalog to page 7

All MORNSUN Guangzhou Science & Technology Co. catalogs and technical brochures

  1. LSxx-K3BxxSS

    4 Pages

  2. L003-10Bxx

    4 Pages

  3. FC-F18D

    4 Pages

  4. FC-L01D

    5 Pages

  5. K12T-16A-P

    7 Pages

  6. LMF320-20BXX

    5 Pages

  7. FS-TD01D

    2 Pages

  8. QP12W08S-37

    4 Pages

  9. TD321SCAN

    5 Pages

  10. TD301DCANHE

    4 Pages

  11. LSxx-K3BxxSS

    4 Pages

  12. QA151M

    4 Pages

  13. E_XT-1WAR2

    4 Pages

  14. URF1D_QB

    8 Pages

  15. HK_S

    4 Pages

  16. TxxxxGP

    3 Pages

  17. TFxxxxN

    5 Pages

  18. TFxxxxGN

    3 Pages

  19. QA1201C-20

    4 Pages

  20. QA2401C-20

    4 Pages

  21. QA156D-24

    3 Pages

  22. QAxx1

    4 Pages

  23. QAW

    4 Pages

  24. QA01C

    4 Pages

  25. QA

    5 Pages

  26. QAxxxD

    4 Pages

  27. FT-BX1D

    4 Pages

  28. T1100L-F

    2 Pages

  29. TxxxxL

    3 Pages

  30. TxxxxHL

    6 Pages

  31. TW147HL

    5 Pages

  32. TSx01W-EX-xx

    4 Pages

  33. TSx00W-EX-xx

    4 Pages

  34. TSFx02W-EX

    4 Pages

  35. TRxxxPW-EX

    5 Pages

  36. TCxxxPW-EX

    4 Pages

  37. TAxxxW-EX-xx

    4 Pages

  38. TRxxxPW

    4 Pages

  39. TCxxxPW

    4 Pages

  40. TAxxxW-xx

    4 Pages

  41. TAx06W-xx

    3 Pages

  42. TAxxxPW

    5 Pages

  43. T1100(N)NS

    3 Pages

  44. TFWxxxN

    4 Pages

  45. T1100L

    2 Pages

  46. TRPxxxxxP

    5 Pages

  47. TxxxxP

    6 Pages

  48. TExxxxN

    6 Pages

  49. MCP100

    4 Pages

  50. FI-B03D

    3 Pages

  51. FC-xxxD

    4 Pages

  52. FC-B01D

    5 Pages

  53. FC-A01D

    5 Pages

  54. FC-L01DV1

    3 Pages

  55. FC-LX1D2

    8 Pages

  56. FC-LX1D

    8 Pages

  57. TD5(3)01MCAN

    5 Pages

  58. TDx01D485H-E

    4 Pages

  59. TDx01D485H-A

    4 Pages

  60. TDHx01D485H

    4 Pages

  61. TDx01D485H

    4 Pages

  62. TDx01D232H

    4 Pages

  63. VRB_ZP-6WR3

    5 Pages

  64. VRB_YMD-6WR3

    5 Pages

  65. VRA_YMD-6WR3

    5 Pages

  66. URB_MT-3WR3

    5 Pages

  67. F_XT-2WR2

    5 Pages

  68. IF_XT-1WR2

    4 Pages

  69. F_XT-1WR2

    5 Pages

  70. B_S-3WR2

    3 Pages

  71. F_S-3WR2

    4 Pages

  72. WRF_S-3WR2

    6 Pages

  73. WRE_S-3WR2

    6 Pages

  74. WRB_S-3WR2

    6 Pages

  75. WRA_S-3WR2

    6 Pages

  76. WRF_S-1WR2

    6 Pages

  77. WRE_S-1WR2

    6 Pages

  78. WRB_S-1WR2

    6 Pages

  79. WRA_S-1WR2

    6 Pages

  80. IF_S-2W

    3 Pages

  81. IB_S-2W

    3 Pages

  82. F_S-2WR2

    5 Pages

  83. E_S-2WR2

    5 Pages

  84. B_S-2WR2

    5 Pages

  85. A_S-2WR2

    5 Pages

  86. IF_S-1W

    4 Pages

  87. B_S-1WR2

    6 Pages

  88. H_S-2WR2

    5 Pages

  89. H_S-1WR2

    5 Pages

  90. LD20-10Bxx

    7 Pages

  91. LD10-20Bxx

    6 Pages

  92. LD12-20Bxx

    7 Pages

  93. LD05-23Bxx

    5 Pages

  94. LD03-10BxxR2

    5 Pages

  95. URA_LD-30WR3

    9 Pages

  96. VRB_LD-20WR3

    8 Pages

  97. VRB_LD-30WR3

    8 Pages

  98. VRA_LD-20WR3

    8 Pages

  99. VRB_LD-15WR2

    9 Pages

  100. VRA_LD-15WR2

    9 Pages

  101. VRB_LD-15WR3

    8 Pages

  102. B0550LD-1WR2

    4 Pages

  103. B0560LD-1WR2

    4 Pages

  104. VRB_LD-50W

    8 Pages

  105. LS03-16BxxSS

    5 Pages

  106. LS05-15BXXSS

    5 Pages

  107. LS01-15BXXSS

    5 Pages

  108. IB_LS-1W

    4 Pages

  109. URB_LD-20WR3

    8 Pages

  110. URA_LD-20WR3

    8 Pages

  111. URA_YMD-6WR3

    6 Pages

  112. URB1D_LD-20W

    8 Pages

  113. URB1D_LD-15W

    8 Pages

  114. URB1D_XD-10W

    5 Pages

  115. URB1D_YMD-6W

    5 Pages

  116. URB_LD-30WR3

    9 Pages

  117. URB_ZP-6WR3

    5 Pages

Archived catalogs

  1. A05_XT-1WR3

    4 Pages

  2. LHE05-20Bxx

    5 Pages

  3. TEMxxxxCN

    4 Pages

  4. TEMxxxxAN

    4 Pages

  5. TExxxxCN

    3 Pages

  6. TExxxxHN

    6 Pages

  7. TExxxxAN

    3 Pages

  8. LN02-12Bxx

    5 Pages

  9. KC24RT

    5 Pages

  10. QC962-8A

    5 Pages

  11. QP12W05S-37

    3 Pages

  12. FC-CX3D

    4 Pages

  13. FC-CXXD

    5 Pages

  14. TDx02D232H

    3 Pages

  15. VRA_ZP-6WR3

    5 Pages

  16. IB_XT-1WR2

    4 Pages