Catalog excerpts
Dual-Mode Remote Thermometer Description Moore Industries’ BIMETAL Dual-Mode Remote Thermometer provides on-site indication of process temperature conditions, and simultaneously provides a mV or ohm signal proportional to temperature for input to a transmitter, Remote Terminal Unit (RTU), controller, recorder, indicator, PLC, DCS or SCADA system. No Power Supply Required—The BIMETAL requires no power supply at the point of measurement. It is composed of a rugged thermowell probe assembly that contains Moore Industries’ RTD or thermocouple WORM sensor, combined with a large analog display. Both the sensor and display are NIST traceable, and can be quickly calibrated in the field. Combination BIMETAL Thermometer and Temperature Transmitter Moore Industries offers a complete range of termperature transmitters for converting the BIMETAL’s low-level mV or ohm signal to a 4-20mA or 1-5Vdc signal. This high-level, noise-resistant signal is ideal for sending process data long distances back to a field-mounted RTU or directly to a control room. The BIMETAL’s large, easy-to-read display can be accurately read at numerous viewing angles. Easy-to-Read Bimetal Thermometer • Local temperature indication on a large 3-inch dial • 0-250°F and 0-500°F dial ranges • Hermetically sealed per ASME B40.3 Figure 1. The BIMETAL’s large, easy-to-read dial comes in 0-250°F and 0-500°F ranges. DIAL CONFIGURATIONS • Field-adjustable calibration • NIST traceable calibration of up to 1% of reading Integral RTD and Thermocouple Probes • Provides remote monitoring of process conditions • Choice of mounting styles • Hermetically-sealed, high-temperature wires • High accuracy of up to 0.04% of reading (0.1% of reading is standard) • mV or ohm output, or 4-20mA or 1-5Vdc when combined with a Moore Industries temperature transmitter • Installs in either 0.25-inch or 0.38-inch thermowell bores
Open the catalog to page 1BIMETAL Dual-Mode Remote Thermometer Ordering Information Unit Sensor Type BIMET Dual-Mode Remote Thermometer PT1-3 Platinum RTD; 3-Wire; 100 ohm; alpha = 0.00385 PT1-4 Platinum RTD; 4-Wire; 100 ohm; alpha = 0.00385 PT10-3 Platinum RTD; 3-Wire; 1000 ohm; alpha = 0.00385 PT10-4 Platinum RTD; 4-Wire; 1000 ohm; alpha = 0.00385 TC-JU J-Type T/C; Ungrounded TC-KU K-Type T/C; Ungrounded Stem DIA. D25 0.25-Inch Diameter (standard) D38 0.38-Inch Diameter Dial Range S316 Stainless Steel 316 (standard) S304 Stainless Steel 304 Options -0.04% RTD with 0.04% of reading calibration capability -0.06% RTD...
Open the catalog to page 2All Moore Industries catalogs and technical brochures
-
SB
2 Pages
-
LH
2 Pages
-
TMZ
8 Pages
-
CPT (Current/Voltage Input)
8 Pages
-
CCS - Cable Concentrator System
12 Pages
-
HIM HART® Interface Module
8 Pages