Catalog excerpts
Since its beginning in 1957, FLO-TORK has been recognized (or its original approaches to motion design technology and its ability to specialize in rotary actuator applications. These achievements have been made possible by a strong engineering staff that enables the company to custom design components-tailoring unique materials, tolerances and design specifications to each customer's needs. _ evolution and growth in military and industrial fluid power applications. In the mid-1980s FLO-TORK, Inc. recognized the need to diversify to continue its consistent growth philosophy. In analyzing its...
Open the catalog to page 2Torque Plug Ductile Iron Cylinder Tube Spring Retainer Ductile Iron Ductile Iron Ductile Iron Adjustable Stops Spring Follower Ductile Iron Cast Iron Ductile Iron STANDARD FEATURES Heavy duty housing, torque plug and piston rod design STANDARD OPTIONS Double acting or spring return Tandem designs Canted torque plug High pressure hydraulic service Locking Heavy dutuction Special seal materials Operating pressure to 200 psig (varies by model) Large U-cup piston seals - Buna-N Temperature range - 0 to 200 0 F Internal corrosion protection Plated housing fasteners External stroke adjustors Bolt...
Open the catalog to page 3Cylinder Tube Torque Plug Ductile Iron Ductile Iron Ductile Iron Spring Retainer Bearing Ductile Iron Cast Iron Ductile Iron Spring Follower Ductile Iron Adjustable Stops Ductile Iron STANDARD FEATURES STANDARD OPTIONS Heavy duty housing, torque plug and piston rod design Double acting or spring return Tandem designs Canted torque plug High pressure hydraulic service Tie rod construction Special seal materials Operating pressures to 200 psig (varies by model) Large U-cup pistons seals - Buna-N Temperature range - 0 to 200 0 F Internal corrosion protection Plated housing fasteners External...
Open the catalog to page 4Spring Canister Steel Cylinder Tube Cast Iron Ductile Iron Ductile Iron Adjustable Stops Torque Plug Ductile Iron STANDARD FEATURES Heavy duty housing, torque plug and piston rod design STANDARD OPTIONS Double acting or spring return Containerized spring canister Tie rod construction High pressure hydraulic service Operating pressures to 125 psig (varies by model) Pre-loaded lip type piston seals - Buna-N Temperature range - 0 to 200 0 F External stroke adjustors Three point piston rod bearing Pre-lubricated metal bearing surfaces Special seal materials Special coatings/corrosion protection...
Open the catalog to page 5MD-Double Acting • MS-Spring Return • HO-Hydraulic Overide • XC-Special Coatings XM-Special Materials • X-Special Features SPRING STROKE* • CW-Clockwise (Standard) SPRING SIZE Models Only * For Double Acting actuators CW to close is standard for the canted torque plug.
Open the catalog to page 6Choosing the correct actuator is as important as selecting the correct valve. The information offered below is presented in an effort to assist in the choice of the proper actuator for your application. If you are unsure of your selection and feel you need assistance, do not hesitate to contact your local FLO-TORK representative or the FLO-TORK Corporate office. Prior to beginning the actuator selection process it is necessary that you have the following information: 1) The maximum torque requ ired to break (unseat) the valve element from its fully closed (seated) position, against the...
Open the catalog to page 7SPRING RETURN FAIL CLOSE (CLOCKWISE) ACTUATORS NOTE: The SERIES M spring return torque charts are based on a clockwise spring stroke and provide the start (break), run (minimum) and end (closing) torque outputs for the spring stroke in addition to the pressure stroke output torques for the same positions of rotation. The spring break torque (highest spring output torque) is shown at the 90 0 position. This corresponds with the lowest pressure stroke output torque which is also at the 90 0 position. NOTE: The actuator output torque must exceed the maximum torque requ irements of the valve at...
Open the catalog to page 8NOTE: The torque chart values are minimum output based on ideal conditions. The actual torque output may vary based on adjustor stop screw position, alignment, service time between lubrication, & other influencing factors. *NOTE: Torque output exceeds model capacity at this pressure.
Open the catalog to page 9NOTE: The torque chart values are minimum output based on ideal conditions. The actual torque output may vary based on adjustor stop screw position, alignment, service time between lubrication, & other influencing factors. *NOTE: Torque output exceeds model capacity at this pressure.
Open the catalog to page 10SPRING TORQUE SPRING SIZE NOTE: The torque chart values are minimum output based on ideal conditions. The actual torque output may vary based on adjustor stop screw position, alignment, service time between lubrication, & other influencing factors. *NOTE: Torque output exceeds model capacity at this pressure.
Open the catalog to page 11SPRING TORQUE SPRING SIZE NOTE: The torque chart values are minimum output based on ideal conditions. The actual torque output may vary based on adjustor stop screw position, alignment, service time between lubrication, & other influencing factors. *NOTE: Torque output exceeds model capacity at this pressure.
Open the catalog to page 12SPRING TORQUE SPRING SIZE NOTE: The torque chart values are minimum output based on ideal conditions. The actual torque output may vary based on adjustor stop screw position, alignment, service time between lubrication, & other influencing factors. *NOTE: Torque output exceeds model capacity at this pressure.
Open the catalog to page 13SPRING TORQUE SPRING SIZE NOTE: The torque chart values are minimum output based on ideal conditions. The actual torque output may vary based on adjustor stop screw position, alignment, service time between lubrication, & other influencing factors. *NOTE: Torque output exceeds model capacity at this pressure.
Open the catalog to page 14SPRING TORQUE SPRING SIZE NOTE: The torque chart values are minimum output based on ideal conditions. The actual torque output may vary based on adjustor stop screw position, alignment, service time between lubrication, & other influencing factors. *NOTE: Torque output exceeds model capacity at this pressure.