1. Catalogs
  2. Monitran
  3. Hand held Vibration Monitor MTN/VM110

Hand held Vibration Monitor MTN/VM110
1 /2Pages

Hand held Vibration Monitor MTN/VM110

Hand held Vibration Monitor MTN/VM110
1 /2Pages

Catalog excerpts

Hand held Vibration Monitor MTN/VM110-1

DS0058 Issue 4 Page 1 of 2 Monitran Ltd Monitor House Hazlemere Rd Penn Bucks UK HP10 8AD Tel: +44 (0) 1494 816569 Fax: +44 (0) 1494 812256 email: [email protected] www.monitran.co.uk Monitran reserves the right to alter the specification without prior notice MTN/VM110 Hand Held Vibration Meter · Multiple Measurements · LCD Display · AC or DC Outputs · Carrying Case · Battery Powered Peak 2000ìm 10 Range 2000 mm/sec 200 mm/sec 20 mm/sec 200ìm 20ìm 200g 20g 2g L.P. Filter (kHz) Vibration Meter 5 20 r.m.s VM 110 Monitran Ltd. Off Standard Vibration Meter, Probe & Accessories The MTN/VM110 Vibration Meter is a battery powered, portable instrument designed to operate with a constant current type accelerometer (10mV/g sensitivity) to make vibration measurements simple and convenient. Both RMS and Peak detection of acceleration, velocity and displacement can be made in three ranges. A switched low pass filter for the reduction of wide band noise is provided. An AC output via a ‘D’ type output socket allows the connection of additional filters or a signal analyser. A DC output is also provided to drive a chart recorder. Standard Package ORDER CODE PART NO. DESCRIPTION MTN/VM110 MTN/2100 MTN/MM001 MTN/PS001 VIBRATION METER HAND HELD PROBE MAGNETIC BASE ADAPTER HAND HELD SPIKE ADAPTER OTHER ACCESSORIES AVAILABLE

 Open the catalog to page 1
Hand held Vibration Monitor MTN/VM110-2

DS0058 Issue 4 Page 2 of 2 Technical Specification Measurement Ranges Acceleration: 2g, 20g, 200g Velocity: 20mm/sec, 200mm/sec, 2000mm/sec Displacement: 20ìm, 200ìm, 2000ìm Frequency Range Upper Frequency, selectable low pass filters of 5kHz, 10kHz, 20kHz Lower Frequency fixed, Acc. 5Hz, Vel. 10Hz, Dis. 15Hz Detector Switch selectable: RMS or Peak Display 12.7mm, 3½ digit LCD. 3 readings per second Accuracy (10 mV/g Input) Figures are for the VM110 only, since input transducers will affect the overall system accuracy. All readings are ±1 digit added to the following full-scale errors. Acc. 1.5%...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.