SafePoint Fail-Safe Rotary Paddle Level Switch
8Pages

{{requestButtons}}

Catalog excerpts

SafePoint Fail-Safe Rotary Paddle Level Switch - 1

Layout 1 table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:8.00pt "Arial", sans-serif; } .font1 { font:14.00pt "Arial", sans-serif; } .font2 { font:7.50pt "Franklin Gothic Medium", sans-serif; } .font3 { font:8.00pt "Georgia", serif; } .font4 { font:26.00pt "Georgia", serif; } SafePoint® Self-Validating JCtIC: RotaryPaddle Bin Monitor T The Leader In Self-Validating Point Level Monitors T "Fail-Safe" PLUS Y Microcontroller-based Reliability T Material Sens and Fault Outputs T Choice of Process Connections & Accessories T Hazardous Location Approvals Available BULLETIN 253

Open the catalog to page 1
SafePoint Fail-Safe Rotary Paddle Level Switch - 2

Layout 1 table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Franklin Gothic Medium", sans-serif; } .font3 { font:7.00pt "Georgia", serif; } ▼ Self-Validating Elimintes Costs Associated With Unexpected Sensor Failures ▼ Industry-First Magnetic Sensing Technology (Patented) ▼ Monitor Sensor Health, Not Just System Power Failure - "Fail-Safe" PLUS ▼ Twist On/Off Cover - No More Bolts! ▼ Wiring Access - 2 Conduit Entrances ▼ Motor Shuts Off When Paddle Is Impeded...

Open the catalog to page 2
SafePoint Fail-Safe Rotary Paddle Level Switch - 3

Layout 1 table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Arial", sans-serif; } .font1 { font:7.20pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:9.00pt "Franklin Gothic Medium", sans-serif; } .font4 { font:7.00pt "Georgia", serif; } .font5 { font:8.00pt "Georgia", serif; } .font6 { font:24.00pt "Georgia", serif; } .font7 { font:24.00pt "Times New Roman", serif; } N/l TϏTTT7 TYPICAL APPLICATIONS INCLUDE, BUT ARE NOT LIMITED TO: 7 6 Feeds Silica Sand Pellets Dust Rubber Metals Regrind Coal Peanuts Foundry Sand...

Open the catalog to page 3
SafePoint Fail-Safe Rotary Paddle Level Switch - 4

Layout 1 table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:4.80pt "Arial", sans-serif; } .font2 { font:5.00pt "Arial", sans-serif; } .font3 { font:6.00pt "Arial", sans-serif; } .font4 { font:7.00pt "Arial", sans-serif; } .font5 { font:10.00pt "Arial", sans-serif; } .font6 { font:14.00pt "Arial", sans-serif; } .font7 { font:19.00pt "Arial", sans-serif; } .font8 { font:23.00pt "Arial", sans-serif; } .font9 { font:15.00pt "Franklin Gothic Medium", sans-serif; } .font10 { font:11.00pt "Microsoft Sans Serif", sans-serif; }...

Open the catalog to page 4
SafePoint Fail-Safe Rotary Paddle Level Switch - 5

Layout 1 table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.50pt "Arial", sans-serif; } .font1 { font:4.80pt "Arial", sans-serif; } .font2 { font:5.00pt "Arial", sans-serif; } .font3 { font:5.40pt "Arial", sans-serif; } .font4 { font:6.00pt "Arial", sans-serif; } .font5 { font:7.00pt "Arial", sans-serif; } .font6 { font:22.00pt "Arial", sans-serif; } .font7 { font:9.00pt "Franklin Gothic Medium", sans-serif; } .font8 { font:15.00pt "Franklin Gothic Medium", sans-serif; } .font9 { font:5.00pt "Georgia", serif; } .font10 { font:8.00pt "Georgia", serif; } MOUNTING...

Open the catalog to page 5
SafePoint Fail-Safe Rotary Paddle Level Switch - 6

Layout 1 table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.50pt "Arial", sans-serif; } .font1 { font:4.80pt "Arial", sans-serif; } .font2 { font:5.40pt "Arial", sans-serif; } .font3 { font:6.00pt "Arial", sans-serif; } .font4 { font:7.00pt "Arial", sans-serif; } .font5 { font:7.20pt "Arial", sans-serif; } .font6 { font:8.00pt "Arial", sans-serif; } .font7 { font:22.00pt "Arial", sans-serif; } .font8 { font:9.00pt "Franklin Gothic Medium", sans-serif; } .font9 { font:8.00pt "Georgia", serif; } ORDERING INFORMAT! Dimensions are shown in inches with millimeter...

Open the catalog to page 6
SafePoint Fail-Safe Rotary Paddle Level Switch - 7

Layout 1 table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.80pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:23.00pt "Arial", sans-serif; } .font4 { font:9.00pt "Franklin Gothic Medium", sans-serif; } .font5 { font:7.00pt "Georgia", serif; } SPECIFICATIO Power Requirements: 115 VAC (+/- 15%); 9 VA; 50/60 Hz 230 VAC (+/- 15%); 9 VA; 50/60 Hz 24 VAC/DC (+/- 15%); 11VA 6562 ft (2000 m) max Suitable for outdoors II 4 (Reduced to 2 via enclosure) -40°F (-40°C) to +150°F (65°C) to +250°F...

Open the catalog to page 7
SafePoint Fail-Safe Rotary Paddle Level Switch - 8

Layout 1 table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } 44W320 Keslinger Road ▼ P.O. Box 8048 ▼ Elburn, IL 601 19-8048 ▼ 800-766-6486 ▼ 630-365-9403 ▼ Fax 630-365-5646 www.flexar.info ▼ www.monitortech.com ▼ www.monitortech.typepad.com ▼ monitor@monitortech.com DOC-000-253A Rev.7.10032008

Open the catalog to page 8

All Monitor Technologies catalogs and technical brochures

  1. TC-1 & TC-3

    2 Pages