Datasheet - Electronic Sounder C&S YA50
1 /3Pages

Datasheet - Electronic Sounder C&S YA50

Datasheet - Electronic Sounder C&S YA50
1 /3Pages

Catalog excerpts

Datasheet - Electronic Sounder C&S YA50-1

Multi-purpose Audible Signalling device designed for use in Fire, Commercial, Industrial & Marine applications. PRODUCT FEATURES • Max sound output 112 dB (A) @ 1m • IP66 rated as standard • 32 selectable tones meeting international regulations • Flame retardant ABS enclosure • Stainless steel fixings • 2 stage alarm • Independently selectable second stage (optional) • Low current consumption • Robust, reliable and simple to install Product Approvals Marine Equipment Directive MED Regulations EN 54-3:2014 incl. A1:2019 IEC 60092-504:2016 IEC 60533:2015 Module B (BSI/MED/3.53/756093) Module D (BSI/MED/PC/756095) Merchant Shipping (Marine Equipment) Regulations EN 54-3:2014 incl. A1:2019, IEC 60092-504:2016, IEC 60533:2015 Module B (BSI/UK/3.53/738807) Module D (BSI/UK/PC/738808) EN 54-3 : 2001 + A1:2002 + A2:2006 Type B 2797-CPR-713892 UK +44 (0) 121 446 5322 FR +33 (0)1 70 72 12 71 [email protected] www.moflash.com BS EN 54-3 : 2001 + A1:2002 + A2:2006 Type B 0086-CPR-774029 BS EN 54-3 : 2001 + A1:2002 + A2:2006 Type B KM 713890 Compliant

 Open the catalog to page 1
Datasheet - Electronic Sounder C&S YA50-2

TECHNICAL DATA Electrical Data Ambient Conditions Maximum Volume Output Volume Control Adjustment 2 Stage Alarm with predetermined second stage as standard. Selectable second stage option available (DC units only) (2) Devices should be mounted to a suitable flat wall or bulkhead avoiding any undue vibration and using the two lugs projecting from the case. The lugs are bored 8mm on 153mm centres. The minimum length of fixing screw required is 25mm. To maintain the IP rating of the enclosure, the cable entries must be fitted with a suitably rated cable gland (included). Max cable termination 2.5mm...

 Open the catalog to page 2
Datasheet - Electronic Sounder C&S YA50-3

SELECTION Version Operational Voltage Order Number Network Rail 086/024000 Certificate PA05/07230 For Use on TOWS / TAWS systems

 Open the catalog to page 3