1. Catalogs
  2. MJK
  3. MAGFLUX FLOW METERS

MAGFLUX FLOW METERS

MAGFLUX FLOW METERS

MAGFLUX FLOW METERS

Product catalog summary
Overview
MJK MagFlux® electromagnetic flow meters are designed for high accuracy, stability, and low maintenance. They feature a straight-through flow sensor and self-cleaning electrodes, eliminating the need for regular maintenance and ensuring no pressure drop or flow rate influence.

Specifications
MagFlux® flow meters are available in sizes ranging from DN 3 to DN 1400 (1/8” to 56”) with various mounting options including flange and wafer. The materials used include PTFE, hard rubber, and soft rubber liners, with stainless steel electrodes. The system accuracy is better than ±0.25%, and it operates within a temperature range of -20 to +150°C for liquids.

Sensor Setup and Configuration
The MagFlux® system simplifies sensor setup with a unique registration code that automatically configures the sensor and meter electronics. This eliminates the need for external equipment and reduces the risk of installation errors.

Flow and Batch Control Functions
The MagFlux® Converter includes a 4-20 mA output, relays for control and alarms, and digital inputs for batch or alarm reset. It features user-friendly navigation and password protection for settings.

Data Logging and Networking
MagFlux® offers an on-board electronic chart recorder and data logger, capable of storing up to 160,000 data points. Data can be exported via USB or Bluetooth, and the system supports RS-485 communication with Modbus protocol for SCADA integration.

Installation Flexibility
The MagFlux® Converter and Display can be installed locally or remotely, with the Display capable of managing multiple Converters and Sensors. This flexibility allows for optimal placement of components to suit operational needs.

Technical Details
The MagFlux® Converter features a galvanically isolated 4-20 mA output, digital outputs, and Modbus communication. It is housed in a polycarbonate enclosure with an IP 67 rating, ensuring durability and protection against environmental factors.

Contact Information
MJK Automation ApS, Byageren 7, DK-2850 Nærum, Denmark. Tel: +45 45 56 06 56, Fax: +45 45 56 06 46, Website: www.mjk.com
See more

Catalog excerpts

MAGFLUX FLOW METERS-1

ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401

 Open the catalog to page 1
MAGFLUX FLOW METERS-2

PROVEN AND RELIABLE FLOW MEASUREMENT MJK MagFlux® flow meters combine high accuracy, stability and low maintenance. Without moving parts, straight through flow sensor and self-cleaning electrodes there is virtually never any need for maintenance, there is no influence on the flow rate, and no pressure drop because of the flow sensor. MagFlux® flow meters use a tested and 2 approved sensing technology giving linear readings over a large range in closed pressurized pipe systems.

 Open the catalog to page 2
MAGFLUX FLOW METERS-3

LARGE SELECTION OF SIZES AND MATERIALS Hard rubber Hard rubber Soft rubber

 Open the catalog to page 3
MAGFLUX FLOW METERS-4

A BREAKTHROUGH IN SENSOR SET-UP SIMPLICITY MJK’s unique registration code for each sensor feeds all the necessary data into the meters electronics. In a matter of seconds the registration is completed, and the sensor characteristics and meter electronics are fully matched and ready to perform flow measurements. It is safer than other systems that require memory chips that get lost or damaged, or complicated procedures requiring external equipment that have potential for mistakes. MagFlux® sensor direction is also configured in the 4 electronics, so there is no way to install a sensor backwards....

 Open the catalog to page 4
MAGFLUX FLOW METERS-5

Batching, batch counters, for- ward, reverse and net totalizers lays for control and alarms, one digital input for batch or alarm reset, keypad start and stop of batch counters and reset of With its cell-phone like navi- counters, totalizers and alarms. gation, finding and managing Pop-up windows alert the user these features is simple, but about operational and alarm you can also password protect functions which are automati- your settings. cally logged and easily reset.

 Open the catalog to page 5
MAGFLUX FLOW METERS-6

BEST- I N - CL ASS DATA LOGGI NG AND NET WO RKI NG MagFlux® is the first to bring you an RS-485 communication with Modbus that graphs flow rates and shows protocol along with registers, so that the date, time and flow rate for each several MJK MagFlux® flow meters data point. Behind the scene is a data can be operated seamlessly from a logger that you set up with the data control room. logging interval. To capture data for MagFlux® never gets out of date. The your permanent records simply use USB port also allows for uploading of new software, features and several (optional) in the MagFlux® Display...

 Open the catalog to page 6
MAGFLUX FLOW METERS-7

LOCATE AND CONFIGURE MAGFLUX YOUR WAY MagFlux® Converter and Display can stay locally with the flow sensor or can be logging for one, two, three, or four Converters and Sensors in their own network to save space and cost. for set-up, viewing and data A single Display can be used installed remotely. The Display can be up to 1000 m (3000 ft) from a Converter, allowing the Converter to be where the electrical and control connections are, while the Display can be where the operators are. The Converter can be separated from the sensor, too! This allows for even more flexibility to locate the Converter,...

 Open the catalog to page 7
MAGFLUX FLOW METERS-8

MagFlux® Sensor Mounting Housing: Painted carbon or stainless steel Liner: Hard rubber, soft rubber or PTFE Electrode: Stainless steel 1.4571 (AISI 316). On order Hastelloy, titanium or platinum Built-in grounding electrode Liquid:      20 to +150° C / -5 to +302° F, depending of type. Surroundings: -20 to +60° C / -5 to +140° F (converter mounted on sensor)     -20 to +80° C /14 to +176° F (converter remote mounted) IP 67 (with gel potting IP 68) / NEMA 4X (with gel potting NEMA 6P) MagFlux® Converter Accuracy ± 0,1% of measurement (system accuracy better than ± 0,25 %) From MagFlux® sensor...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.