1. Catalogs
  2. MJK
  3. HYDROSTATIC LEVEL MEASUREMENT

HYDROSTATIC LEVEL MEASUREMENT

HYDROSTATIC LEVEL MEASUREMENT

HYDROSTATIC LEVEL MEASUREMENT

Product catalog summary
Overview
MJK submersible level transmitters are designed for accurate level measurement in various environments, including open channels, groundwater wells, reservoirs, and tanks. They are known for their durability and precision, even in hazardous and harsh conditions.

Applications
The transmitters are suitable for use in wastewater treatment, drinking water systems, geo-technical applications, and industrial settings. They are effective in measuring levels in sewage tanks, storm flow basins, aeration tanks, sludge thickeners, water wells, and process tanks.

Product Specifications
  • Expert 700: Designed for water wells, featuring AISI 316L body and diaphragm, with an outer diameter of 16 mm and analog 4-20 mA output.
  • Expert 7070/7070T: Suitable for water wells and storage, with AISI 316L housing and diaphragm, 22 mm diameter, and outputs including analog 4-20 mA, voltage, or Modbus.
  • Expert 1400: Used in water wells and storage, with AISI 316 housing, ceramic diaphragm, 22 mm diameter, and analog 4-20 mA output.
  • Expert 7060: For wastewater and process water, featuring PP housing, AISI 316 diaphragm, 60 mm diameter, and multiple output options.
  • Expert 3400: Applicable for drinking, waste, and process water, with PPS housing, ceramic diaphragm, 50 mm diameter, and analog 4-20 mA output.


Technical Characteristics
The transmitters offer measuring ranges from 0 to 300 meters, with a temperature range of -10 to +70°C. They provide high accuracy with a temperature drift of 0.02%/°C and a measuring range accuracy of ≤ 0.2% FS. The devices are powered by 12-30 V DC and have various output signals, including analog and digital Modbus RTU.

Certifications and Approvals
The transmitters are certified under CE and ATEX standards, suitable for hazardous areas with specific temperature classifications. They are also UL approved for Class I, Division 1, Group A-D environments.

Contact Information
MJK Automation ApS, Byageren 7, DK-2850 Nærum, Denmark. Tel: +45 45 56 06 56, Fax: +45 45 56 06 46, Website: www.mjk.com
See more

Catalog excerpts

HYDROSTATIC LEVEL MEASUREMENT-1

SUBMERSIBLE LEVEL TRANSMITTERS BROCHURE EN 2.75 EXPERT BROCHURE 1401

 Open the catalog to page 1
HYDROSTATIC LEVEL MEASUREMENT-2

OUTSTAN DING DU R AB ILIT Y AN D H IGH PR ECI S ION MJK level transmitters are designed for level measurement by immersion in open channels gutters, ground water wells, reservoirs and tanks - even in potentially dangerous sites. MJK level transmitters are robust and de2 signed to withstand hard impacts in slurries, wastewater and sludge. MJK level transmitters excel to the top of their category for their long lasting performance in wastewater treatment plants, pumping stations, waterworks and industrial plants. Over the many years of being installed around the world, MJK level transmitters are...

 Open the catalog to page 2
HYDROSTATIC LEVEL MEASUREMENT-3

M J K H Y D R O S TAT I C T R A N S M I T T E R A R E U S E D E V E R Y W H E R E - even in some very harsh environments WASTEWATER For level measurement in tanks with sewage, storm flow basins, aeration tanks, sludge thickeners and have enough precision for level measurement for open channel flow measurement. DRINKING WATER Level measurement in water wells and tanks, level control in water towers, filter pools, ion exchangers and chemical mixing/precipitation tanks. GEO-TECHNICAL Level measurement in tunnels, mines and dewatering under larger buildings. INDUSTRIAL Measurement in all types of...

 Open the catalog to page 3
HYDROSTATIC LEVEL MEASUREMENT-4

Our level transmitters have a sturdy design with housing in re-enforced plastic or stainless steel. Cables are insulated with PUR, and steel reinforced to achieve very high tensile strength. Sensing membranes are made with either ceramic or stainless steel. Outputs are analog two-wire 4-20 mA, voltage or digital Modbus RTU. Expert 700 Water Wells AISI 316L AISI 316L Outer diameter Ø 16 mm Analog 4-20 mA Application: Water Wells and Water Storage and Processing Housing: AISI 316L Diaphragm: AISI 316L Features: Outer diameter Ø 22 mm Output: Analog 4-20 mA, spænding eller Modbus Application: Water...

 Open the catalog to page 4
HYDROSTATIC LEVEL MEASUREMENT-5

LEVEL TRANSMITTER LEVEL TRANSMITTER '^^HYDROSTATIC LEVEL TRANSMITTER 70 Application: Water Wells and Water Storage Application: Wastewater and process water Application: Drinking, waste and process water

 Open the catalog to page 5
HYDROSTATIC LEVEL MEASUREMENT-6

Expert™ hydrostatic level transmitters Measuring ranges from Measurement principle Piezo resistive or capacitive ceramic measuring cell Temperature range Temperature Drift Temperature Operation Measuring range accuracy Output Signals Analogue 4-20 mA voltage or digital Modbus RTU Materials, house Materials membrane Acid proof steel or ceramic 99.9% pure AL2O3 Measuring cell seals Supply voltage 2 x 0,5 mm2, shieldedt (+ 5 x 0,15 mm2 programming contacts) Insulation PVC/PUR 12 m, or by request IP68, waterproof CE: EN50081-1, EN50082-1 ATEX: II 2G Ex ia IIC T6 (-20°C≤Ta≤40°C) II 2G Ex ia IIC T5...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.