Group: Mitsubishi
Catalog excerpts
▼ MITSUBISHI for a greener tomorrow MITSUBISHI ELECTRONIC MULTI-MEASURING INSTRUMENT Super-S Series
Open the catalog to page 1MITSUBISHI Electric Multi-Measuring Instrument SS Series features high performance and crystal clear display. With simple operating functions, SS Series is the best support your measuring and monitoring systems. Expand Line-up Enhanced Measuring Functions »Improved Measuring Accuracy »Three model line-up »High-spec class »Standard class »Economy class ∑ ME96 Super-S Series Features ················· 4
Open the catalog to page 2• Password function •Special primary voltage/current and special secondary voltage are settable • Periodic monitoring function •Advanced alarm display • Motor starting current mask • Large bar-graph display • Special display .^^^^ • High-brightness backlight
Open the catalog to page 3I0DBUS® RTU System (ME96SSH-MB/ME96SSR-MB with ME-0052-SS96 (optional plug-in module)) Central monitor ► MODBUS® RTU communication system optimizes computer monitoring operations ►Attachment of ME-0052-SS96 (optional) enables remote monitoring of the contact input signal and on/off control of the contact output signal ► Digital input signals can be latched for over 30ms, and there is no need for external latch optional unit <MODBUS® RTU Interface Specifications> <Optional Plug-in Module ME-0052-SS96> • Digital Input: 5 points (24VDC) • Digital Output: 2 points (35VDC) CC-Link System...
Open the catalog to page 4ME96 Super-S Series Features Expand Line-up Three Model Line-up Model name Transmission/Option specifications Main measurement items A, DA, V = ±0.1% W, var, VA, Hz = ±0.2% PF = 1.0% Wh = class 0.5s (IEC 62053-22) varh, Vah = class 2.0 (IEC 62053-23) Harmonics = 31st-deg (max) Rolling demand Plug-in module (options) • Analog/Pulse/Contact output/input • CC-Link communication • Digital input/output (for MODBUS® RTU communication) A, DA, V = ±0.2% W, var, VA, Hz = ±0.5% PF = 2.0% Wh = class 1.0 (IEC 62053-21) varh = class 2.0 (IEC 62053-23) Harmonics = 13th-deg (max) MODBUS® RTU communication...
Open the catalog to page 5ME96 Super-S Series Features Succeeded Display Functions Large Bar Graph Display »Bar Graph Display Each measuring items can be displayed by a bar graph. With bar graph display, one can grasps the rated value and percentage against the alarm value instantly. (1) Bar Graph Fixed Display Measuring items can be displayed by bar graph. The mark indicates that display is fixed. Furthermore, the + and – buttons can be used to change the display between items measured. Alarm indicator Note: Alarm indicator blinks when it is set on alarm mode. (2) Digital Values Display by Bar Graph Values on the...
Open the catalog to page 6Impressive Monitoring Functions Advanced Alarm Display (1) Backlight blinks when an alarm occur. (2) Automatic or manual alarm cancel can be selected. (3) Upper/lower limits of up to four points can be monitored. (4) Alarm output delay time can be set. Time of alarm output after the maximum value and minimum value is reached can be set. With this function,alarm output caused by frequency change at start-up current of a motor and start-up of private power generating facility can be avided. Furthermore, maximum value and minimum value do not update during alarm delay. Current Motor starting...
Open the catalog to page 7ME96 Super-S Series Features riety of Complementary Features Password Function With the password function, the following items can be protected from an accidental execution. Special Primary Voltage/Current and Special Secondary Voltage are settable (1) Special primary current Under 10A: Top two digits setting Over 10A: Top three digits setting (3) Special secondary voltage Three phase 4-wire system Three phase 3-wire, Single phase 2-wire system (2) Special primary voltage Under 100V: Top two digits setting Over 100V: Top three digits setting Periodic Monitoring Function Power consumption...
Open the catalog to page 8Test Function »Even during a setup of a facility, where no current/voltage input is found, analog output, pulse output, alarm output, contact output, and communication data is replied. This allows for checkup of wiring and monitoring program system. *Depending on the optional unit and settings, the test function may not be available (may not be displayed). (1) Communications Test qDisplay »The same as for the operating mode, display patterns and other data are shown as set. »Both maximum and minimum values can be displayed. wCommunication data »Communication items and value are the same one...
Open the catalog to page 9Specifications ■ME96SSH-MB Model name Phase wire Three phase 4-wire, Three phase 3-wire (3CT, 2CT), Single phase 3-wire, Single phase 2-wire (common use) Current Voltage 5AAC, 1AAC (common use) Three phase 4-wire: 277/480VAC (max) Three phase 3-wire: Delta connections: 220VAC (max), Star connections: 440VAC (max) Single phase 3-wire: 220/440VAC (max) Single phase 2-wire: Delta connections: 220VAC (max), Star connections: 440VAC) Apparent power (VA) Measurement items and accuracy Imported, Exported Reactive energy (varh) Imported lead, lag Exported lead, lag 1st to 31st degree (odd number...
Open the catalog to page 10Phase wire Three phase 4-wire, Three phase 3-wire (3CT, 2CT), Single phase 3-wire, Single phase 2-wire (common use) Current Voltage 5AAC, 1AAC (common use) Three phase 4-wire: 277/480VAC (max) Three phase 3-wire: Delta connections: 220VAC (max), Star connections: 440VAC (max) Single phase 3-wire: 220/440VAC (max) Single phase 2-wire: Delta connections: 220VAC (max), Star connections: 440VAC) Apparent power (VA) Measurement items and accuracy Imported, Exported Reactive energy (varh) Imported lead, lag Exported lead, lag 1st to 13th degree (odd number degree only) 1 to 13 degree (odd number...
Open the catalog to page 11Specifications ■ME96SSE-MB Model name Phase wire Three phase 4-wire, Three phase 3-wire (3CT, 2CT), Single phase 3-wire, Single phase 2-wire (common use) Current Voltage 5AAC, 1AAC (common use) Three phase 4-wire: 277/480VAC (max) Three phase 3-wire: Delta connections: 220VAC (max), Star connections: 440VAC (max) Single phase 3-wire: 220/440VAC (max) Single phase 2-wire: Delta connections: 220VAC (max), Star connections: 440VAC) Voltage (V) Measurement items and accuracy Operating time Measuring method Instantaneous value Type A/V: RMS calculation, W: Digital multiplication, PF: Power ratio...
Open the catalog to page 12All MITSUBISHI ELECTRIC AUTOMATION catalogs and technical brochures
-
MELFA Family
64 Pages
-
Compact PLC Family Catalogue
122 Pages
-
HMI-Family Visualisation Tools
90 Pages
-
MELFA Family
64 Pages
-
The Automation Book
156 Pages
-
MELSEC iQ-R series/System Q/L series
152 Pages
-
QS90SR2SP
4 Pages
-
FX3UC
4 Pages
-
L Series
4 Pages
-
FX Family
88 Pages
-
Q/L-Family
114 Pages
-
COGNEX
2 Pages
-
MELSEC iQ-F SERIES
2 Pages
-
ME96-NSR
32 Pages
-
ECOWEBSERVER III
16 Pages
-
PRODUCT OVERVIEW
2 Pages
-
POWER & ENERGY PORTFOLIO
2 Pages
-
RV-2SD-SQ BROCHURE Ver. B
3 Pages
-
FX3S Brochure
6 Pages
-
GT14 Handy GOT Brochure
2 Pages
-
CNC DRIVES GENERAL CATALOG (V-M)
11 Pages
-
FX3GE Brochure
2 Pages
-
GT16 Handy Brochure
2 Pages
-
FX3U-ENET-ADP Brochure
4 Pages
-
RV-SQ-RH-SQH BROCHURE Ver. B
4 Pages
-
ME96-SS Series Brochure
32 Pages
-
GT14 Brochure
3 Pages
-
F920GOT F930GOT Brochure
2 Pages
-
FX2NC-ENET-ADP Brochure
2 Pages
-
FX3U-1PG Brochure
2 Pages
-
LOW VOLTAGE SWITCHGEAR
12 Pages
-
Safety & Flexibility
16 Pages
-
MR-MQ100 Single Axis Motion
4 Pages
-
LD77MH Simple Motion Module
12 Pages
-
ST Series
4 Pages
-
GOT1000
13 Pages
-
F900
16 Pages
-
E1000
12 Pages
-
QE81-WH Energy Module
8 Pages
-
ME96-NSR Energy Meter
32 Pages
-
CC-Link
29 Pages
-
EnergyPAQ
2 Pages
-
M70 Series
8 Pages
-
C70 Series For iQ Platform
19 Pages
-
M700V Series
11 Pages
-
WS Series Circuit Breaker
192 Pages
-
WS-V Series
260 Pages
-
QS Safety PLC and CC-Link Safety
56 Pages
-
Q Series
31 Pages
-
MES Interface IT
7 Pages
-
Q Series Redundant System
31 Pages
-
iQ Sequence Controller
33 Pages
-
Inverter family
20 Pages
Archived catalogs
-
Programmable Logic Controllers
28 Pages
-
MELFA Industrial Robots
50 Pages
-
Frequency Inverters
8 Pages
-
Global and open Field Network
12 Pages
-
Control Units
8 Pages
-
Melsec PLC
85 Pages