Group: AMETEK
Catalog excerpts
PRODUCT LINE
Open the catalog to page 1VISION STATEMENT To be the customer’s first call when performance matters.
Open the catalog to page 2COMPANY At Magnetrol® we understand all the ways that level matters to your business. That’s why it matters to us. No matter who you are or what your industry produces, level matters. We realize that what’s most important to customers is not an individual product or service, but the way it helps provide the measurements that are essential to their industries. Despite the differences across the many market segments we serve, there’s one thing all applications have in common: Accurate, reliable level measurement is a key component of each and every one
Open the catalog to page 3The majority of the devices manufactured by Magnetrol® International are designed and custommade to the specifications and requests of our customers. Over the years a great expertise has been gained in different fields. Below is a partial list of metals that we have extensive experience with: • 321 stainless steel • 304/304L stainless steel • 316/316L stainless steel • Carbon steel • Chrome Molybdenum steel • (Super) Duplex stainless steel • Monel • Hastelloy • Incolloy and Inconel types Working with these various metals has resulted in over 130 established in-house welding procedures. A...
Open the catalog to page 4Measurement solids level Measurement interface Measurement Flow • Ultrasonic Contact Ultrasonic Non-Contact Thermal Dispersion Magnetic Level Indicator Pulse Burst Radar Density control Guided Wave Radar Detection solids PRODUCT FAMILY Detection flow Detection interface Detection liquid level Measurement liquid level Displacer Transmitter Mechanical Flow Magnetrol® level and flow controls use state-of-the-art technology and are produced under strict quality procedures of ISO 9001 - PED 2014/68/EU. MAGNETROL quality is achieved by using fully traceable materials, ASME IX qualified welders...
Open the catalog to page 5GUIDED WAVE RADAR Guided Wave Radar is based upon the principle of Time Domain Reflectometry (TDR). TDR utilizes pulses of electromagnetic energy, which are transmitted down a probe. When a pulse reaches a liquid surface that has a higher dielectric than the air/vapor in which it is traveling, the pulse is reflected. An ultra high-speed timing circuit precisely measures the transit time and provides an accurate measurement of the liquid level or the liquid-liquid interface. Many of these devices are overfill safe due to the fact that the reference signal is generated above the process seal....
Open the catalog to page 6GUIDED WAVE RADAR ECLIPSE® 706 Guided wave radar level transmitter DESCRIPTION The Eclipse® Model 706 is an advanced two-wire, loop-powered, 24 VDC guided wave radar transmitter with a superior signal strength to take on a broad range of challenging high pressure/ high temperature applications. An extensive line of dedicated coaxial, caged coaxial, single and twin rod probes delivers accurate and reliable level control. The innovative dual compartment enclosure positions wiring and electronics in the same plane, and angled to maximize ease of wiring, configuration, set-up and data display....
Open the catalog to page 7GUIDED WAVE RADAR ECLIPSE® 706 PROBE SELECTION Coaxial GWR probes - liquids Application/Type Function Level - Interface Standard temp. probe Level - Interface High pressure probe Level - Interface HTHP probe Saturated steam Steam probe Overfill safe Temperature saturated steam Maximum pressure εr 1.4 εr ≥ 1.7 εr 4 εr 10 Available probe length Standard Enlarged Material of construction 316/316L (1.4401/1.4404) Hermetic glass ceramic, Inconel Hermetic glass ceramic, Inconel No Hermetic glass ceramic, PEEK HT, Inconel Full vacuum Full vacuum Full vacuum Process seal type Teflon TFE with Viton...
Open the catalog to page 8GUIDED WAVE RADAR ECLIPSE® 706 PROBE SELECTION Caged GWR probes - liquids Application/Type Function Level - Interface Standard temp. probe Level - Interface High pressure probe Level - Interface HTHP probe saturated steam Maximum pressure Overfill safe Temperature εr 1.7 εr 4 εr 10 Available probe length Material of construction 316/316L (1.4401/1.4404) No Hermetic glass ceramic, Inconel No Hermetic glass ceramic, Inconel Full vacuum Full vacuum Process seal type Vacuum service Viscosity cP (mPa.s) Liquid Teflon TFE with Viton o-rings Negative pressure, but no hermetic seal 10000 ® Strong...
Open the catalog to page 9GUIDED WAVE RADAR ECLIPSE® 706 PROBE SELECTION Single rod rigid GWR probes - liquids Application/Type Function Overfill safe Level Standard temp. probe Level High pressure probe Level HTHP probe saturated steam Maximum pressure Available probe length Material of construction 316/316L (1.4401/1.4404) Teflon® TFE with Viton® o-rings (3) Negative pressure, but without hermetic seal 10000 Hermetic glass ceramic, Inconel Hermetic glass ceramic, Inconel Full vacuum Full vacuum Film coating Moderate buildup Process seal type Vacuum service Viscosity cP (mPa.s) Liquid Strong buildup 1.2 minimum...
Open the catalog to page 10GUIDED WAVE RADAR ECLIPSE® 706 PROBE SELECTION Flexible GWR probes - liquids Application/Type Function Level Single flexible Standard temp. probe Level Single flexible HP probe Level - Interface Single flexible HTHP probe Level - Interface Twin flexible Standard temp. probe Overfill safe Temperature saturated steam Available probe length Material of construction Teflon® TFE with Viton® o-rings (5) Negative pressure, but without hermetic seal 10000 Hermetic glass ceramic Hermetic glass ceramic Full vacuum Full vacuum Teflon® TFE with Viton® o-rings (5) Negative pressure, but without hermetic...
Open the catalog to page 11GUIDED WAVE RADAR ECLIPSE® 706 PROBE SELECTION Flexible GWR probes - solids Application/Type Function Level Single flexible Standard temp Level Twin flexible Standard temp Overfill safe Temperature saturated steam Maximum pressure Dielectrics (1) εr 1.4 Available probe length Material of construction Teflon® / PEI (4) Negative pressure, but without hermetic seal 10000 Teflon® / PEI (4) Negative pressure, but without hermetic seal 1500 Film coating PFA insulated 316/316L rod Process seal type Vacuum service Viscosity cP (mPa.s) Liquid Moderate buildup Strong buildup 1.2 minimum dielectric...
Open the catalog to page 12All Magnetrol - AMETEK catalogs and technical brochures
-
Interface In The Field
14 Pages
-
Emulsion In The Field
9 Pages
-
Aurora® Magnetic Level Indicator
28 Pages
-
Atlas™ Magnetic Level Indicator
24 Pages
-
STEAM DRUM LEVEL MATTERS
1 Pages
-
INTERFACE IN THE FIELD
1 Pages
-
Echotel® 355
4 Pages
-
Echotel® 335
4 Pages
-
Power Generation
16 Pages
-
Petroleum Refining
16 Pages
-
Natural Gas Processing
12 Pages
-
Seal Pots
4 Pages
-
Mass Flow Measurement
12 Pages
-
Interface Level Measurement
8 Pages
-
Heat Rate Awareness
8 Pages
-
Ethylene Applications
8 Pages
-
Thermatel® TD1/TD2
16 Pages
-
Kotron® 082
4 Pages
-
Enhanced Jupiter®
16 Pages
-
GEMINI™
32 Pages
-
Aurora®
32 Pages
-
Atlas™
24 Pages
-
Horizon TM Model 704
8 Pages
-
Eclipse® Enhanced 705 Hygienic
12 Pages
-
Eclipse® Enhanced 705
8 Pages
-
Pneumatic Tuffy®
12 Pages
-
Models T5x & T6x
8 Pages
-
Models T20/T21
12 Pages
-
Series B73 and Series 75
12 Pages
-
Series 3
24 Pages
-
Model J52
2 Pages
-
Model B40
4 Pages
-
TUFFY® II
12 Pages
-
Digital E3 Modulevel®
12 Pages
-
Floating Roof Detection
16 Pages
-
APM Pneumatic Modulevel®
12 Pages
-
Flue Gas Desulferization
8 Pages
-
Energy Management
4 Pages
-
API 2350 Overfill Prevention
8 Pages
-
PULSAR ® R96
1 Pages
-
Water & Wastewater
12 Pages
-
Displacer Switches
20 Pages
-
Displacer Transmitters
4 Pages
-
Guided Wave Radar
12 Pages
-
Magnetic Level Indicators
12 Pages
-
Magnetostrictive
16 Pages
-
Pulse Burst Radar
8 Pages
-
Thermal Dispersion
12 Pages
-
Ultrasonic Contact
4 Pages
-
Vibrating Rod Switches
4 Pages
-
R Series High Temp Switch
12 Pages
-
Series K Pneumatic Switch
8 Pages
-
J Series Pneumatic Switch
8 Pages
-
Liquid Displacer Level Switches
16 Pages
-
Crude Oil Processing
8 Pages
-
Product Line Quick Reference
8 Pages