Genesis Models ED1 & ED2 Multiphase Detector
16Pages

{{requestButtons}}

Catalog excerpts

Genesis Models ED1 & ED2 Multiphase Detector - 1

Genesis Models ED1 & ED2 High Performance Multiphase Detector DESCRIPTION The Genesis Multiphase Detector is a Time Domain Reflectometry (TDR)-based, 24 VDC level detector designed to accurately measure the various layers in interface level measurement applications. Encompassing a number of significant engineering accomplishments, this leading edge level detector is designed to provide measurement performance beyond that of many of the more traditional technologies. Utilizing patented "Top-Down" and "Bottom-Up" signals, along with advanced level detection algorithms, this single device can be used in a wide variety of interface applications ranging from very light hydrocarbons to water-based media. This detector, like other Magnetrol devices, is designed to maximize ease of wiring, configuration, and viewing of the versatile graphic LCD display. The Genesis supports both the Field Device Integration (FDI) and Enhanced DD (EDDL) standards, which allow viewing of valuable configuration and diagnostic information in tools such as PACTware ™, AMS Device Manager, and various HART ® Field Communicators. APPLICATIONS MEDIA: Hydrocarbons to water-based media (Dielectric Constant εr = 1.4–100) VESSELS: Most process, separator, or storage applications up to rated probe temperature and pressure. CONDITIONS: All interface measurement and control applications including those with thick/dynamic emulsion layers, process conditions exhibiting, foam, surface agitation, high fill/empty rates, and varying dielectric media or specific gravity. Measures Multiple Phases within Interface Applicati

Open the catalog to page 1
Genesis Models ED1 & ED2 Multiphase Detector - 2

FEATURES • 24 VDC multiphase detector with up to four (4) 4-20mA outputs for convenient control of top level, top of emulsion, water level, and sediment • Concurrent Top-Down and Bottom-Up signal generation • Level measurement not affected by changing media characteristics. • No need to move levels for calibration • 4-button keypad and graphic LCD display allow for convenient viewing of configuration parameters and echo curves • Proactive diagnostics advise not only what is wrong, but also offer troubleshooting tips. • Probe designs up to +200 °C/70 bar (+400 °F/1000 psi) • Main electronics...

Open the catalog to page 2
Genesis Models ED1 & ED2 Multiphase Detector - 3

Two Signals One transmitting for the top-down measurement. Air Signals are transmitted from both ends of the probe. The top-down signal provides a clear view of the oil layer. The bottom-up signal provides a clear view of the water level. One transmitting for the bottom-up measurement. The coaxial probe is the most efficient of all TDR probe configurations and should be the first consideration in all applications. Analogous to the efficiency of coaxial cable, a coaxial probe allows almost unimpeded movement of the high frequency pulses throughout its length. The electromagnetic field that...

Open the catalog to page 3
Genesis Models ED1 & ED2 Multiphase Detector - 4

The standard coaxial offering for the Genesis is an Enlarged diameter probe that can be generally used for most clean applications. Coaxial Probe Signal Propagation With a PFA coated active center rod surrounded by four (4) reference rods, the 5-conductor Pentarod probe is an alternative probe offering for the Genesis. Although this probe still yields excellent performance, its open design makes it less susceptible to buildup and bridging. Both of the probes offered with the Genesis are unique, and each has specific strengths and weaknesses. While there can be overlap, and both probes can...

Open the catalog to page 4
Genesis Models ED1 & ED2 Multiphase Detector - 5

FUNCTIONAL/PHYSICAL System Design Measurement Principle TDR based electronics combined with patented, proprietary software algorithm Input Measured Variable Level, as determined by time of flight 60 centimeters to 6 meters (2 to 20 feet) Output Type Four (4) 4–20 mA analog outputs, one (1) with HART; 3.8–20.5 mA useable (per NAMUR NE43) Analog: Digital Display: Diagnostic Alarm Selectable: 3.6 mA, 22 mA (meets requirements of NAMUR NE 43), or HOLD last output Diagnostic Indication Meets requirements of NAMUR NE107 User Interface Keypad 4-button menu-driven data entry Graphic liquid crystal...

Open the catalog to page 5
Genesis Models ED1 & ED2 Multiphase Detector - 6

FUNCTIONAL/PHYSICAL Environment Operating Temperature Storage Temperature Electromagnetic Compatibility Meets CE requirement (EN 61326) and NAMUR NE 21 ¿ Surge Protection ANSI/ISA-S71.03 Class SA1 (Shock); ANSI/ISA-S71.03 Class VC2 (Vibration) Performance Reference Conditions Reflection from liquid with a 3 meter (10 foot) probe at +20 °C (+70 °F) Application dependent Application dependent Response Time Initialization Time Less than 30 seconds ¿ Pentarod probes must be used in metallic vessel or stillwell to maintain CE noise immunity RATING PxC and PxF Temperature/Pressure Ratings 1200

Open the catalog to page 6
Genesis Models ED1 & ED2 Multiphase Detector - 7

ENLARGED COAXIAL PROBE PENTAROD PROBE Direct insertion (preferred) or side-mounted chamber Materials — Probe 316/316L (1.4401/1.4404) with PFA coated center rod Process Seal Teflon® TFE with Viton® o-rings ¡ Coaxial Pentarod Probe Outside Diameter Process Connection Threaded 3" or larger; Various ASME, EN1092 60 to 610 cm (24 to 240 inches) Available Probe Length Transition Zones ➂ Process Temperature Dielectric Range Negative pressure, but not hermetic seal Maximum Viscosity ¿ 2nd digit E=English, M=Metric ¡ Other o-ring materials available upon request. ➂ Top Transition Zone: The detector...

Open the catalog to page 7
Genesis Models ED1 & ED2 Multiphase Detector - 8

DIMENSIONS millimeters ∅ 34 (1.12) Flexible Conduit to Main Electronics Insertion Length Insertion Length Enlarged Coaxi

Open the catalog to page 8
Genesis Models ED1 & ED2 Multiphase Detector - 9

AVERTISSEMENT! Danger d’explosion éventuel. Ne brancher ou débrancher des équipements que si l’alimentation électrique a été coupée ou si la zone est réputée non dangereuse. These units are in compliance with the EMC-directive 2014/30/EU, the PED-directive 2014/68/EU and the ATEX directive 2014/34/EU. SENSORS, TEST & CALIBRATION SENSORS, TEST & CALIBRATION

Open the catalog to page 9
Genesis Models ED1 & ED2 Multiphase Detector - 10

SENSORS, TEST & CALIBRATION SENSORS, TEST & CALIBRATION

Open the catalog to page 10
Genesis Models ED1 & ED2 Multiphase Detector - 11

SENSORS, TEST & CALIBRATION SENSORS, TEST & CALIBRATION

Open the catalog to page 11