Catalog excerpts
EXTERNAL CAGES for Eclipse Level Transmitters DESCRIPTION The Eclipse 705 is ideally suited to operate in any type of external cage ≥ 2" (DN 50). This bulletin provides guidelines to easily retrofit any displacer transmitter in an existing external cage or to specify a suitable cage for your Eclipse transmitter. For ordering information about the Eclipse amplifier and GWR probe, ask for Eclipse 705 bulletin BE 57-101. The tradition to build cages ... F E AT U R E S • 2" (DN50) or 3" (DN 80) Carbon or Stainless steel cages (other materials upon request) • Flanged or sealed external cage • Up to 5,7 m (224") measuring range • Up to 345 bar (5000 psi) pressure rating • Standard and NACE construction • Eclipse is not affected by changing media variables such as e.g. density, pressure, dielectrics, pH, viscosity, ... • Easy and cost effective retrofit with a minimal of modifications to existing installations C O N F I G U R AT I O N S 3 possible process connection styles may exist: Side/side cage For Top/bottom connection, see ordering information in bulletin 57-101. The 7EK probe/cage assembly is a self-contained assembly with a single model code. Customized installation dimensions Code compliance construction Special tank connections Extreme temperature modifications Special exterior surface preparation and finish PED - 97/23/EC (Pressure Equipment Directives) NACE MR -01-75 ➀ ASME - ANSI B31.3 ➀ IBR (Indian Boiler Regulations) ➀ ➀ Consult factory for proper par
Open the catalog to page 1In order to match the proper Eclipse transmitter with the proper external cage, consider the following: - Type of application - use the applicable Eclipse GWR probe. See Eclipse 705 bulletin BE 57-101. - Overfill proof: Overfilling occurs when the level rises above the max level - radar based equipment may provide erroneous output in this zone unless an adapted design is used. Overfill proof GWR probes are always safe to use - only in cases where the application demands for a different probe type, other selections should be considered and the recommended precautions followed. - Cage size...
Open the catalog to page 21. Order code for Eclipse cage Order code for modified cages: put an "X" in front of the closest matching order code and specify the modifications/adders separately: e.g. XF2A-DA2D-100 X = material certification EN 10204 / DIN 50049-3.1.B 2. Order code for Eclipse transmitter: see bulletin BE 57-101. CAGE AND FLANGE RATING complete order code for ECLIPSE cage 3
Open the catalog to page 32" FLANGED AND SEALED CAGES – DIMENSIONS IN MM (INCHES) Flanged cages ANSI body cage flanges Select Eclipse GWR probes with pressure matching ANSI flanges Measuring range (Probe insertion length) Measuring range (Probe insertion length) Measuring range (Probe insertion length) Side/Side connection NPT/Socket weld Side/Bottom connection ANSI RF Flange Side/Side connection ANSI RF Flange Sealed cages 3/4" NPT body cage connection Select Eclipse GWR probes with 3/4" NPT process connection Measuring range Measuring range Measuring range P (Probe insertion length) (Probe insertion length) (Probe...
Open the catalog to page 4Probe length Eclipse = (dimension “P” + measuring range) arounded to the nearest cm value, e.g. 1523 mm 152 cm or 1526 mm = 153 cm
Open the catalog to page 53" FLANGED AND SEALED CAGES – DIMENSIONS IN MM (INCHES) Flanged cages ANSI body cage flanges Select Eclipse GWR probes with pressure matching ANSI flanges Measuring range (Probe insertion length) Measuring range (Probe insertion length) Measuring range (Probe insertion length) Side/Side connection NPT/Socket weld Side/Bottom connection ANSI RF Flange Side/Side connection ANSI RF Flange Sealed cages 3/4" NPT body cage connection Select Eclipse GWR probes with 3/4" NPT process connection Measuring range Measuring range Measuring range P (Probe insertion length) (Probe insertion length) (Probe...
Open the catalog to page 6Probe length Eclipse = (dimension “P” + measuring range) arounded to the nearest cm value, e.g. 1523 mm 152 cm or 1526 mm = 153 cm
Open the catalog to page 7QUALITY ASSURANCE - ISO 9001:2000 THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS. OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001:2000 AND OUR TOTAL COMPANY IS COMMITTED TO PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE. ALL MAGNETROL ELECTRONIC AND ULTRASONIC LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE FULL YEAR FROM THE DATE OF ORIGINAL FACTORY SHIPMENT. IF RETURNED WITHIN THE WARRANTY...
Open the catalog to page 8All Magnetrol - AMETEK catalogs and technical brochures
-
Interface In The Field
14 Pages
-
Emulsion In The Field
9 Pages
-
PRODUCT LINE CATALOGUE
106 Pages
-
Aurora® Magnetic Level Indicator
28 Pages
-
Atlas™ Magnetic Level Indicator
24 Pages
-
STEAM DRUM LEVEL MATTERS
1 Pages
-
INTERFACE IN THE FIELD
1 Pages
-
Echotel® 355
4 Pages
-
Echotel® 335
4 Pages
-
Power Generation
16 Pages
-
Petroleum Refining
16 Pages
-
Natural Gas Processing
12 Pages
-
Seal Pots
4 Pages
-
Mass Flow Measurement
12 Pages
-
Interface Level Measurement
8 Pages
-
Heat Rate Awareness
8 Pages
-
Ethylene Applications
8 Pages
-
Thermatel® TD1/TD2
16 Pages
-
Kotron® 082
4 Pages
-
Enhanced Jupiter®
16 Pages
-
GEMINI™
32 Pages
-
Aurora®
32 Pages
-
Atlas™
24 Pages
-
Horizon TM Model 704
8 Pages
-
Eclipse® Enhanced 705 Hygienic
12 Pages
-
Pneumatic Tuffy®
12 Pages
-
Models T5x & T6x
8 Pages
-
Models T20/T21
12 Pages
-
Series B73 and Series 75
12 Pages
-
Series 3
24 Pages
-
Model J52
2 Pages
-
Model B40
4 Pages
-
TUFFY® II
12 Pages
-
Digital E3 Modulevel®
12 Pages
-
Floating Roof Detection
16 Pages
-
APM Pneumatic Modulevel®
12 Pages
-
Flue Gas Desulferization
8 Pages
-
Energy Management
4 Pages
-
API 2350 Overfill Prevention
8 Pages
-
PULSAR ® R96
1 Pages
-
Water & Wastewater
12 Pages
-
Displacer Switches
20 Pages
-
Displacer Transmitters
4 Pages
-
Guided Wave Radar
12 Pages
-
Magnetic Level Indicators
12 Pages
-
Magnetostrictive
16 Pages
-
Pulse Burst Radar
8 Pages
-
Thermal Dispersion
12 Pages
-
Ultrasonic Contact
4 Pages
-
Vibrating Rod Switches
4 Pages
-
R Series High Temp Switch
12 Pages
-
Series K Pneumatic Switch
8 Pages
-
J Series Pneumatic Switch
8 Pages
-
Liquid Displacer Level Switches
16 Pages
-
Crude Oil Processing
8 Pages
-
Product Line Quick Reference
8 Pages