Group: AMETEK
Catalog excerpts
TM MAGNETIC LEVEL INDICATOR
Open the catalog to page 1Magnetically coupled liquid level indicators, or MLIs, are in widespread use throughout process industries. Originally designed as an alternative to sight and gauge glass devices, the MLI is now commonly used in both new construction and plant expansion. • Numerous chamber styles (or configurations) are available for each design. Consult factory for choices not listed in this bulletin. Magnetic level indicators are precision engineered and manufactured to indicate liquid level accurately, reliably, and continuously. These units are completely sealed and require no periodic maintenance. MLIs...
Open the catalog to page 2Patent Pending 1 InstaSeal™ valve allows for an effective dry nitrogen purge 2 Double o-ring endplug ensures a reliable seal that keeps moisture out 3 All-metal high contrast powder coated or anodized flags are wider to enhance overall visibility 4 Robust 316 stainless steel enclosure designed to face the elements 5 Extruded shatter-resistant viewing window enhances visibility Dual Scale Single Scale and allows the flags to position closely to the float, enhancing the magnetic coupling Scale Options: • Feet/Inches • Meters/Millimeters • Running Inches • Percent (5 % increments) Each flag...
Open the catalog to page 3ORION FLOAT TECHNOLOGY Weld ring: Secures float cap to main body. Flux ring: Absorbs magnetic energy and directs it outward. Magnets: A full array surrounds the float with a strong and consistent magnetic field. The float contained within the magnetic level indicator is perhaps the most important element of the instrument. Its structural design, volume displacement, weight, and buoyancy force are all carefully considered when a float is specified for a particular application. Our engineers have designed and tested hundreds of floats to gather the most accurate data available. We have...
Open the catalog to page 4HIGH-TEMPERATURE INSULATION Orion specializes in custom fibreglass insulation blankets for MLIs of all shapes and sizes. They are constructed with high-quality materials capable of constant contact with temperatures up to 540 °C (1000 °F). This insulation is available as personnel protection or with heat tracing options for freeze protection or process temperature maintenance. CRYOGENIC INSULATION & FROST EXTENSION To facilitate operation where the product is kept cold via chillers, refrigerants, and condensers, cryogenic insulation is provided. By insulating the MLI with a specialized...
Open the catalog to page 6OCT REED CHAIN TRANSMITTER SPECIFICATIONS Measuring range © FM approval limited to 300 cm (118") length
Open the catalog to page 7MOUNTING TO ATLAS Position the OES switch on the MLI body so that the centerline of the switch housing is at the desired switch point level. Unscrew the housing cover and ensure that the switch is oriented so that the arrow on the internal mechanism is pointing toward the top of the MLI. Install the clamps around the MLI and over the mounting brackets on the top and bottom of the housing. Tighten the clamps until the switch is firmly secured to the MLI. Replace the housing cover. If required, place the insulation between the MLI body and the OES switch before securing the clamps. WIRING The...
Open the catalog to page 8MOUNTING TO ATLAS Position the ORS switch on the MLI body so that the centerline of the stainless steel tube which houses the switch is at the desired switch point level. The switch should be oriented so that the green grounding screw is closest to the top of the MLI. Install the clamps around the MLI and over the mounting tabs of the switch. Tighten the clamps until the switch is firmly secured to the MLI. If required, place the insulation between the MLI body and the ORS switch before securing the clamps. WIRING The switch leads are colour coded as follows: white = common black = normally...
Open the catalog to page 9Model: ' Digit:" X = product with a specific customer requirement 1 PRODUCT NAME 1 Atlas™ Magnetic Level Indicator 2 UNIT OF MEASUREMENT Metric (cm) 3 MOUNTING CONFIGURATION & CHAMBER CONSTRUCTION mn rnrn, luj o mnnr Option 1 Connection orientation Option 1 with 3 process Option T with stilling well connections (consult factory) (consult factory)
Open the catalog to page 10Model: ' Digit:" X = product with a specific customer requirement Plastic construction (digit 5 = 1, 2, 3 or 4) - Non-PED 7 | CHAMBER FLANGE(S) TYPE Plastic flanges
Open the catalog to page 11X = product with a specific customer requirement © Only available in combination with digit 9 = A, B or C. © Consult factory for sizes > 1". © Machined flange (to smaller pipe size) if process connection size > chamber size (e.g. 2"/DN50 process connection and 2" chamber). 8 PROCESS CONNECTION TYPE Threaded NPT-M, option M Pipe nipple plain end, option P Pipe nipple butt weld end, option R Threaded NPT-F, option N Socket weld, option Q Threadolet NPT-F, option W Sockolet, option T Weldolet, option S Slip-on flange, option A (process connection size < chamber size) Machined flange, option...
Open the catalog to page 12X = product with a specific customer requirement 101 GASKET STYLE FOR CHAMBER FLANGE(S) Gaskets for metallic flanges Gaskets for plastic flanges 0 Standard gasket for RF flanges with rating up to 300# / PN 63. 0 Standard gasket for RF flanges with rating > 300# / PN 63. Winding material matches chamber material. 0 Standard ring joint for RJ ANSI flanges (digit 7 = J). 0 Ring joint material matches flange material. 111 CHAMBER BOLTING MATERIAL Stainless steel Carbon steel 0 Only available in combination with digit 5 = B or D. 12 VENT SIZE 13 VENT TYPE N None 0 Pressure class of vent flange...
Open the catalog to page 13X = product with a specific customer requirement 14 DRAIN SIZE 15 DRAIN TYPE None © Pressure class of drain flange is as selected in digit 4. 16 CHAMBER MODIFICATION FOR MOUNTING OF OPTIONAL SWITCHES AND/OR TRANSMITTER ATLAS can be combined with various externally mounted accessories, including switches and transmitters. In these cases minor changes to the chamber and float design may be required. For digit 16, match up the MLI product with the appropriate transmitter, switch or combination of both. For OES/ORS switch, refer to the switch selection data for temperature limitations and...
Open the catalog to page 14All Magnetrol - AMETEK catalogs and technical brochures
-
Interface In The Field
14 Pages
-
Emulsion In The Field
9 Pages
-
PRODUCT LINE CATALOGUE
106 Pages
-
Aurora® Magnetic Level Indicator
28 Pages
-
Atlas™ Magnetic Level Indicator
24 Pages
-
STEAM DRUM LEVEL MATTERS
1 Pages
-
INTERFACE IN THE FIELD
1 Pages
-
Echotel® 355
4 Pages
-
Echotel® 335
4 Pages
-
Power Generation
16 Pages
-
Petroleum Refining
16 Pages
-
Natural Gas Processing
12 Pages
-
Seal Pots
4 Pages
-
Mass Flow Measurement
12 Pages
-
Interface Level Measurement
8 Pages
-
Heat Rate Awareness
8 Pages
-
Ethylene Applications
8 Pages
-
Thermatel® TD1/TD2
16 Pages
-
Kotron® 082
4 Pages
-
Enhanced Jupiter®
16 Pages
-
GEMINI™
32 Pages
-
Aurora®
32 Pages
-
Horizon TM Model 704
8 Pages
-
Eclipse® Enhanced 705 Hygienic
12 Pages
-
Eclipse® Enhanced 705
8 Pages
-
Pneumatic Tuffy®
12 Pages
-
Models T5x & T6x
8 Pages
-
Models T20/T21
12 Pages
-
Series B73 and Series 75
12 Pages
-
Series 3
24 Pages
-
Model J52
2 Pages
-
Model B40
4 Pages
-
TUFFY® II
12 Pages
-
Digital E3 Modulevel®
12 Pages
-
Floating Roof Detection
16 Pages
-
APM Pneumatic Modulevel®
12 Pages
-
Flue Gas Desulferization
8 Pages
-
Energy Management
4 Pages
-
API 2350 Overfill Prevention
8 Pages
-
PULSAR ® R96
1 Pages
-
Water & Wastewater
12 Pages
-
Displacer Switches
20 Pages
-
Displacer Transmitters
4 Pages
-
Guided Wave Radar
12 Pages
-
Magnetic Level Indicators
12 Pages
-
Magnetostrictive
16 Pages
-
Pulse Burst Radar
8 Pages
-
Thermal Dispersion
12 Pages
-
Ultrasonic Contact
4 Pages
-
Vibrating Rod Switches
4 Pages
-
R Series High Temp Switch
12 Pages
-
Series K Pneumatic Switch
8 Pages
-
J Series Pneumatic Switch
8 Pages
-
Liquid Displacer Level Switches
16 Pages
-
Crude Oil Processing
8 Pages
-
Product Line Quick Reference
8 Pages