Atlas™ Magnetic Level Indicator
24Pages

{{requestButtons}}

Catalog excerpts

Atlas™ Magnetic Level Indicator - 1

Atlas™ Magnetic Level Indicator DESCRIPTION Magnetically coupled liquid level indicators, or MLIs, are in widespread use throughout process industries. Originally designed as an alternative to sight and gauge glass devices, the MLI is now commonly used in both new construction and plant expansion. Magnetic level indicators are precision engineered and manufactured to indicate liquid level accurately, reliably, and continuously. These units are completely sealed and require no periodic maintenance. MLIs also eliminate vapour or liquid emission problems common with sight and gauge glasses. To complement these products, a complete range of level switches and transmitters is available. Combinations using Jupiter® (magnetostrictive technology) are also possible. The Atlas™ is our standard high-performance magnetic level indicator. Atlas is a single chamber design with either a 2”, 2 1/2”, or 3” chamber diameter, as required by the application. There are several configuration styles including top mount models. Consult factory for choices not listed in this bulletin. ATLAS MLIs are produced in a wide range of materials, including exotic alloys and plastics. We also offer the most complete selection of process connection types and sizes in the industry. ATLAS can be equipped with a variety of level transmitters and switches as well as flag and shuttle indicators with or without stainless steel scales. This enables the ATLAS to be a complete level and monitoring control. FEATURES • Numerous chamber styles (or configurations) are available for each design. Consult factory for choices not listed in this bulletin • Complete range of level switches and level transmitters. • Fabricated, non-magnetic chamber assembly produced in a wide range of metal and plastic materials • A wide range of process connections is available • Precision manufactured float with internal magnets and magnetic flux ring • ASME and EN 1092-1 process connections available • Flag or shuttle type indicator with stainless steel scale to measure height or percentage of level • Standard float stop springs at top and bottom of chamber • Exceptional code qualified welding Feedwater heaters Industrial boilers Oil/water separators Flash drums Surge tanks Gas chillers Deaerators Blowdown flash tanks Hot wells Vacuum tower bottoms Alkyl

Open the catalog to page 1
Atlas™ Magnetic Level Indicator - 2

Atlas™ ML Vent connection Top float stop spring (standard) Welded end plate or flange top Wide range of process connections Flag or shuttle style indicators High level switch (optional) Anodized aluminium or 316 SS indicator rail 316 SS scale for a variety of units: feet/inches meters/millimeters percent % custom Low level switch (optional) Broad range of alloy and plastic chambers Welded end plate or flange bottom Bottom float stop spring (standard) Drain connection Top mount ATLAS (consult factory)

Open the catalog to page 2
Atlas™ Magnetic Level Indicator - 3

Patent Pending 1 Vacuum and sealed with double D-ring & InstaSeal™ valve 2 Double o-ring endplug ensures a reliable seal that keeps moisture out 3 All-metal high contrast powder coated or anodized flags are wider to enhance overall visibility 4 Robust 316 stainless steel enclosure designed to face the elements 5 Extruded shatter-resistant viewing window enhances visibility Dual Scale Single Scale and allows the flags to position closely to the float, enhancing the magnetic coupling Scale Options: • Feet/Inches • Meters/Millimeters • Running Inches • Percent (5 % increments) Each flag...

Open the catalog to page 3
Atlas™ Magnetic Level Indicator - 4

ORION FLOAT TECHNOLOGY Weld ring: Secures float cap to main body. Flux ring: Absorbs magnetic energy and directs it outward. Magnets: A full array surrounds the float with a strong and consistent magnetic field. The float contained within the magnetic level indicator is perhaps the most important element of the instrument. Its structural design, volume displacement, weight, and buoyancy force are all carefully considered when a float is specified for a particular application. Our engineers have designed and tested hundreds of floats to gather the most accurate data available. We have...

Open the catalog to page 4
Atlas™ Magnetic Level Indicator - 5

MAGNETIC LEVEL INDICATOR SPECIFICATIONS Design Single chamber Materials of construction – Chamber Metal alloys: see selection table digit 5 – Rail & window 316 stainless steel (reveal™) rail with polycarbonate window, Aluminium rail with polycarbonate or glass window 316 stainless steel and titanium (exotic alloys available); varies depending on process conditions Construction options ASME B31.1, ASME B31.3, ASME code Stamp [U, Um, S], PED and NACE Industrial, Industrial PED: ATEX II 1 G c T6 (non-electrical equipment) Certified material test report (CMTR) Available upon request Pressure...

Open the catalog to page 5
Atlas™ Magnetic Level Indicator - 6

HIGH-TEMPERATURE INSULATION Orion specializes in custom fibreglass insulation blankets for MLIs of all shapes and sizes. They are constructed with high-quality materials capable of constant contact with temperatures up to 538 °C (1000 °F). This insulation is available as personnel protection or with heat tracing options for freeze protection or process temperature maintenance. CRYOGENIC INSULATION & FROST EXTENSION To facilitate operation where the product is kept cold via chillers, refrigerants, and condensers, cryogenic insulation is provided. By insulating the MLI with a specialized...

Open the catalog to page 6
Atlas™ Magnetic Level Indicator - 7

JUPITER MODEL JM4 MAGNETOSTRICTIVE TRANSMITTER SPECIFICATIONS Measuring Range: ±0.005% of full span or 0.356 mm (0.014 inches) (whichever is greater) 0.8 mm (0.030 inches) or 0.01% of probe length (whichever is greater) Upper Dead Zone: less than 7.6 cm (3 inches) when bottom mounted electronics Lower Dead Zone: less than 7.6 cm (3 inches) when top mounted electronics Power (at terminals) 2-wire: Signal Output: HART®: 16 to 36 VDC FOUNDATION Fieldbus™ Explosion Proof: 9 to 17.5 VDC FISCO/FNICO: 9 to 32 VDC 4-20 mA with HART®: 3.8 to 20.5 mA usable FOUNDATION Fieldbus™: H1 (ITK Ver. 6.1.1)...

Open the catalog to page 7
Atlas™ Magnetic Level Indicator - 8

ELECTRONIC SWITCH SPECIFICATIONS Model: DPDT magnetically actuated, bi-stable cam drive snap action switch Hermetically sealed bi-stable reed switch Supply Voltage: Maximum Dead Band: Temperature Range: Enclosure Material: Cast aluminum (standard) Stainless steel PNEUMATIC SWITCH SPECIFICATIONS Consult factory for more information regarding pneumatic switches. AGENCY APPROVALS – POINT SWITCH & REED CHAIN TRANSMITTER Agency Area Classification Class I, II, III, Div. 1, Groups B,C,D,E,F,G; T6 @ 80 °C; Type 4X Class I, II, III, Div. 1, Groups B,C,D,E,F,G; T6 @ 80 °C; Type 4X Class I, Div. 2,...

Open the catalog to page 8

All Magnetrol - AMETEK catalogs and technical brochures

  1. Seal Pots

    4 Pages

  2. Kotron® 082

    4 Pages

  3. GEMINI™

    32 Pages

  4. Aurora®

    32 Pages

  5. Atlas™

    24 Pages

  6. Models T20/T21

    12 Pages

  7. Series 3

    24 Pages

  8. Model J52

    2 Pages

  9. Model B40

    4 Pages

  10. TUFFY® II

    12 Pages