The document provides detailed mechanical dimensions of the 05020GA DC blower fan, including diameter (φ50 mm), length (20 mm), and mounting hole specifications (2 holes, φ4.3±0.3 mm). Tolerances for various dimensions are specified to ensure precise fitting.
Performance curves illustrate the relationship between static pressure (Ps in Pa) and air flow (Q in m³/min) for different fan classes (K, L, M). These curves help in selecting the appropriate fan model based on required airflow and pressure.
The expected operational life is defined at a 10% failure rate (L10 life), with a reference of 50,000 hours at 25°C, indicating high reliability under specified conditions.
| Model | Rating Voltage (V) | Operating Voltage Range (V) | Rated Current (A) | Input Power (W) | Speed (min⁻¹) | Max Air Flow (m³/min) | Max Static Pressure (Pa) | Noise (dB) | Mass (g) |
|---|---|---|---|---|---|---|---|---|---|
| 05020GA-12K-AA00 | 12 | 4.5 – 13.8 | 0.07 | 0.84 | 3600 | 0.10 | 75.0 | 20.0 | 300 |
| 05020GA-12L-AA00 | 12 | 4.5 – 13.8 | 0.12 | 1.44 | 4600 | 0.13 | 124.0 | 27.0 | 300 |
| 05020GA-12M-AA00 | 12 | 4.5 – 13.8 | 0.18 | 2.16 | 5600 | 0.16 | 184.0 | 32.0 | 300 |
Note: All values are average measurements in free air. Rotation direction is clockwise when viewed from the label side.
05020GA (IB BM5020) ®50X20L DC Blower Fan ■ General Specifications : imm.mx&s Motor Protection Auto Restart / Polarity Protection WBMfa : DC500V T< #(CT 10MQ Insulation Resistance 10MQ or over with a DC500V Megger : AC700V 1s Dielectric Withstand Voltage : K • L Class : -10C ~ +70°C (Operating) Allowable Ambient M Class :-10°C ~ +60°C (Operating) Temperature Range -40°C ~ +70°C (Storage) non-condensing environment Expected Life * Failure Rate: 10% (L10 Life) 25°C 50,000 B#Pb1 (Hours) ■ Characteristic Curves S M Q (m3/min) Air Flow ■ ttt§ Specifications ■ W# Material ^->>7p7-^-y>^77A-f >^-y-W® <J - K& Casing Lower Casing Upper Impeller Bearing Lead Wire Plastic (Black) UL94V-0 Steel Plastic (Black) UL94V-0 Ball Bearing UL1061 AWG26 + :Red, -: Black Rotation: Clockwise as seen from the label side *1: Average Values in Free Air