Product catalog summary
Introduction
Emergency response teams require portable gas detectors to ensure air safety and prevent explosions, especially in confined spaces and during overhaul operations.
Confined Space Entry
Industrial confined spaces necessitate the use of multigas detectors to maintain safe atmospheres for workers.
Overhaul Operations
Single and multigas detectors are essential to assess the need for respiratory protection during overhaul.
Hydrogen Cyanide (HCN) Risks
HCN detection is critical due to its presence in burning materials, with MSA ALTAIR Pro and ALTAIR 5X instruments detecting HCN, which is immediately dangerous to life or health (IDLH) at 50 ppm.
Carbon Monoxide (CO) Risks
CO is toxic at 35 ppm and poses a threat during overhaul or home calls. MSA ALTAIR detectors can detect CO and identify its source.
HazMat Situations
The ALTAIR 5X PID Multigas Detector is ideal for detecting volatile organic compounds in hazardous material situations.
ALTAIR 5X/5X PID Multigas Detector
Features advanced sensor technology, flexibility in monitoring various gases, and a durable design with a loud alarm system.
Sensor Options & Specifications
Details specifications for various gas types and their detection ranges.
MSA XCell® Technology
Provides superior sensor performance with quick response times and extended sensor life.
ALTAIR 4XR Multigas Detector
Known for its durability and reliability, featuring real-time event notification and long battery life.
ALTAIR io™ 4 Gas Detection Wearable
Offers real-time visibility with integrated cellular connectivity and a rugged design.
ALTAIR 2X Gas Detector
Incorporates XCell® Sensor Technology for enhanced performance and durability.
Calibration & Bump Testing
Stresses the importance of regular calibration and bump testing to maintain sensor accuracy and functionality.
GALAXY® GX2 Automated Test System
Provides simple and intelligent testing and calibration for MSA gas detectors, with features for data access and control.
Overview
The document details the GALAXY GX2 Automated Test System and ALTAIR io Dock, highlighting their ease of use, cost efficiency, and advanced features.
Key Features
  • GALAXY GX2 Automated Test System: Initiates testing automatically, supports simultaneous testing of up to ten instruments, and is optimized for MSA XCell Sensors, reducing ownership costs by up to 50%. It includes indicators for calibration gas volume, expiration warnings, and test stand status, supports 18 languages, and replaces the MSA Link Pro Software with the MSA Grid Fleet Manager.
  • ALTAIR io Dock: Facilitates effortless calibration and bump testing, improving compliance and safety. It supports multiple detectors and sensor configurations, with up to three-cylinder holders and 10 test stands, providing compliance reporting to the MSA Grid account without networking requirements.
Specifications and Ordering Information
  • Various models and configurations are available for different gas detectors, including ALTAIR and ALTAIR PRO SINGLE-GAS DETECTOR, ALTAIR 4XR MULTIGAS DETECTOR, and ALTAIR 5X MULTIGAS DETECTOR.
  • Accessories include multi-unit chargers, electronic and standard cylinder holders, demand regulator kits, and memory cards.
  • Calibration cylinders and accessories are available, with specific gas compositions and volumes.
Usage and Compliance
The document emphasizes that products should only be used by trained and qualified individuals, and users must thoroughly read and understand the product instructions and user manuals. Specifications are subject to change without notice.
Additional Information
MSA operates in over 40 countries, and further details can be found on their website. The document also includes ordering information for the ALTAIR io Dock and its accessories.
See more

Catalog excerpts

Gas Detectors for the Fire Service-2

Gas Detectors for the Fire Service Emergency response crews face two basic challenges when entering dangerous environments: • Is the air acceptable for normal, unprotected breathing? • Is the air safe from potential explosions? Portable gas detection equipment can help emergency response crews to meet these challenges. Gas detection needs are expanding. Increasingly, fire departments respond to situations where hazardous substances may be present and proper detection equipment is necessary. MSA provides equipment to meet almost any gas detection need. Home Calls Fire departments often respond...

 Open the catalog to page 2
Gas Detectors for the Fire Service-3

ALTAIR 5X Multigas Detectors provide industry-leading sensor technology with MSA XCell® Sensors, offering typical life of more than double the industry average. MSA’s proprietary Application-Specific Integrated Circuit (ASIC) design miniaturizes sensor controlling electronics, offering superior stability, accuracy, and repeatability. VOC detection is critical in HAZMAT, Arson Investigations, and several applications emerging in the Fire Service. Advanced Photoionization (PID) Detectors are becoming required tools for the fire service for VOC applications. Count on MSA to bring this advanced technology...

 Open the catalog to page 3
Gas Detectors for the Fire Service-4

Gas Detectors for the Fire ServiceALTAIR 4XR Multigas Detector The MSA ALTAIR 4XR Multigas Detector is the world’s toughest and most reliable four-gas monitor. Proven MSA XCell Sensors are among the fastest available, and when paired with the MSA ALTAIR Connect app, this detector can text alarm notifications to supervisors, team members, or other interested parties. < 15-second sensor response time 4- year standard warranty 5- year expected life 24-hour battery run-time Agency-certified IP68 rating (2 m for 1 hour)

 Open the catalog to page 4
Gas Detectors for the Fire Service-5

ALTAIR 2X Gas Detector Introducing the ALTAIR 2X Gas Detector from MSA-the first one or two gas detector that incorporates industryleading XCell® Sensor Technology to deliver unparalleled performance while drastically minimizing total cost of ownership, increasing durability, and delivering enhanced worker safety, compliance, and traceability. Built Tough Like all MSA detectors, ALTAIR 2X Gas Detector is built for durability and designed for the work that is being completed. • Withstands extreme impacts with rugged • Minimal rF interference polycarbonate housing and passes 25 ft. • Full three-year...

 Open the catalog to page 5
Gas Detectors for the Fire Service-6

Gas Detectors for the Fire Service The Importance of Calibration & Bump Testing It is vital to firefighter safety that portable gas detectors are maintained and calibrated properly. All sensors can eventually expire due to loss of sensitivity, slowed response time or both. Because of this, performance of a daily bump test is best practice because it is the only method by which the entire system: instrument, sensors, flow path, power source, alarms, and all electronics can be checked to ensure that it is functioning properly. That’s why most manufacturer instructions recommend a daily bump test...

 Open the catalog to page 6
Gas Detectors for the Fire Service-7

GALAXY® GX2 Automated Test System Simplicity counts with the MSA GALAXY GX2 Automated Test System for advanced safety management and effortless operation. GALAXY GX2 Automated Test System provides simple, intelligent testing and calibration of MSA ALTAIR and ALTAIR PRO Single-Gas Detectors and ALTAIR 4XR and ALTAIR5X Multigas Detectors. Easy-to-use automated test stand offers high performance as either stand-alone unit or integrated portable detector management system, enabling total data access and control of the MSA ALTAIR family Gas Detector fleet. MSA Grid Live Monitor features: secure web-based...

 Open the catalog to page 7
Gas Detectors for the Fire Service-8

The Safety Company ALTAIR io™ Dock The ALTAIR io 4 Dock enables effortless calibration and bump testing which helps to improve compliance and safety. When in the ALTAIR io Dock, the ALTAIR io 4 Gas Detection Wearable knows when it needs a bump test and immediately runs the appropriate test. When the ALTAIR io 4 device is in the Dock, all compliance reporting is sent immediately to your MSA Grid account, helping to minimize the risks associated with manual record keeping or data file management. • Simultaneous testing of multiple detectors and sensor configurations • Test bank can include up to...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.