Heavy Industrial Applications Quick Specs Fabrication and Construction MRO-Maintenance Repair Pressure Tank/Vessel Fabrication Pipe Welding and Shipbuilding Refineries and Foundries Railcar Manufacturing Heavy Equipment Manufacturing MIG (GMAW) Stick (SMAW) TIG (GTAW) Flux Cored (FCAW) Air Carbon Arc Cutting and Gouging (CAC-A) (max 5/16 in carbons) Multiprocess Welding Power Source Input Power Rated Output Weight 3-Phase Power 450 A at 38 VDC, 100% Duty Cycle Build your own system at MillerWelds.com/equiptoweld or see the Stationary and MIGRunner Packages (pg 3). DC multiprocess capability provides versatility and outstanding arc performance in CV (MIG) and CC (Stick, TIG, CAC-A). Fan-On-Demand™ which operates only when needed. This feature reduces noise, energy use and the amount of contaminants pulled through machine. Internal digital voltage control (DVC) enables operator to preset weld voltage in the CV mode before striking an arc. Lift-Arc™ allows TIG starting without the use of high-frequency. Starts the arc without contaminating the weld with tungsten. Inductance/Dig Control with pre-settable digital display to optimize MIG/Stick performance. Line voltage compensation keeps power constant even if power input varies by ±10%. Process selector switch automatically sets contactor requirements, eliminating confusion caused by several switch combinations and making this machine very “operator-friendly.” Excellent power efficiency for exceptional value and return on your investment. Enhanced environmental protection: all critical components housed in protective enclosures. 115 VAC duplex receptacle provides 15 amps of auxiliary power. Thermal overload protection helps prevent machine damage if the duty cycle is exceeded or airflow is restricted. Dimension™ NT 450 MIGRunner ™ Package shown Help codes help troubleshoot and service power source. Help codes are displayed on the volt/amp meters. Reduces the time needed to get the machine back into service. Power source is warranted for 3 years, parts and labor. Original main power rectified parts are warranted for 5 years. Equipment Sales US and Canada An Illinois Tool Works Company 1635 West Spencer Street Appleton, WI 54914 USA Phone: 866-931-9730 FAX: 800-637-2315 International Phone: 920-735-4554 International FAX: 920-735-4125

Open the catalog to page 1
Dimension NT 450 - 2

(Subject to change without notice.) Internal diagnostic Rated Output Amperage Range Voltage Range Amps Input at Rated Load Output, 50/60 Hz, 3-Phase 230 V 380 V 400 V 440 V 460 V 575 V KVA KW Dimensions H: 32-1/2 in (826 mm) including lift eye W: 23 in (585 mm) D: 38 in (966 mm) including strain relief *While idling. Certified by Canadian Standards Association to both the Canadian and U.S. Standards. 1. Ammeter 2. Voltmeter 3. Mode Switch 4. Voltage/Amperage Adjust Control 5. Remote/Panel Switch 6. Inductance/Dig Control 7. Power Switch WELDING AMPERES % DUTY CYCLE

Open the catalog to page 2
Dimension NT 450 - 3

Packages Option #1: Dimension NT Power Sources ™ Purchase components separately. Dimension NT 450 #903 256 (230/460/575 V, 60 Hz) Dimension NT 500 #907 391 (380/400/440 V, 50/60 Hz) Build your own system at MillerWelds.com/equiptoweld Option #2: Dimension NT 450 Stationary Package ™ Stationary display without running gear/ cylinder rack. Dimension NT 450 Stationary Package #951 275 (230/460/575 V, 60 Hz) Comes complete with: Dimension NT 450 power source S-74D wire feeder Bernard® Q-Gun™ Industrial MIG 4/0 Kit: Smith® regulator/flowmeter with 10 ft (3 m) gas hose, 10 ft (3 m) 4/0 feeder...

Open the catalog to page 3
Dimension NT 450 - 4

Genuine Miller Accessories Extension Cables for 14-Pin Plugs to 14-Pin Sockets* #242 208 025 25 ft (7.6 m) #242 208 050 50 ft (15.2 m) #242 208 080 80 ft (24.4 m) Extension cables make a direct connection between the power source and remote control or 24 VAC wire feeder. No messy splicing or adapting required. Polarity Control #042 871 This dual-function control is designed for use with dual wire feeders or any application where electrical isolation and/or polarity reversing of weld current is required. Both functions can be used at the same time. HF-251D-1 High-Frequency Arc Starter/...

Open the catalog to page 4
Dimension NT 450 - 5

Genuine Miller Accessories Remote Controls and Switches Coolant Systems Remote On/Off Control #242 197 025 Allows you to turn your power source on or off from a distance of 25 ft (7.6 m). This is especially useful if your power source is located up in a mezzanine. For more information, see Miller Coolant Systems Lit. Index No. AY/7.2. RMLS-14 #129 337 Momentary- and maintained-contact rocker switch for contactor control. Push forward for maintained contact and back for momentary contact. Includes 26.5 ft (8 m) cord and 14-pin plug. RCC-14 Remote Contactor and Current Control #151 086...

Open the catalog to page 5
Dimension NT 450 - 6

Wire Feeder Options Bench-Style Feeders S-22A S-24A S-74S S-74D S-74DX Bench-Style Dual Feeders D-74S D-74D D-74DX Portable Feeders SuitCase® 8RC SuitCase® 12RC Portable Voltage Sensing Feeders SuitCase® X-TREME™ 8VS SuitCase® X-TREME™ 12VS Aluminum Push-Pull Feeders XR™-S and XR™-D Controls Guns available: XR-Aluma-Pro™ A XR-Aluma-Pro™ W XR-A Pistol Grip Hard Automation Control Detach Kit 70 Series

Open the catalog to page 6
Dimension NT 450 - 8

Ordering Information Equipment and Options Stock No. Description Qty. Price Date: Total Quoted Price:

Open the catalog to page 8

All Miller Electric Mfg. catalogs and technical brochures

  1. TS130

    4 Pages

  2. ED160

    8 Pages

  3. DC296

    4 Pages

  4. AV565

    2 Pages

  5. AY155

    4 Pages

  6. AD73

    12 Pages

  7. EnPak® A60

    8 Pages

  8. SYNCROWAVE

    8 Pages

  9. Fusion160

    4 Pages

  10. LMSW-52 220

    2 Pages

  11. Coolbelt

    2 Pages

  12. Trailblazer

    2 Pages

  13. Live arc

    4 Pages

  14. CP-302

    4 Pages

  15. S-32SL

    4 Pages

  16. Wildcat? 200

    4 Pages

  17. CST? 280

    4 Pages

  18. 70 Series

    8 Pages

  19. R-115

    4 Pages

  20. 22A and 24A

    4 Pages

  21. DC19-8

    8 Pages

  22. AY17-0

    4 Pages

Archived catalogs