iFlaw-100-1

iFlaw-100Ultrasonic Flaw Detector AUTO Contact us Mikrosize Precision Instrument Co.,Ltd A-4035 RuiFeng Business Expo, Wuhu City, China , 241000. Web: www. m i kros i ze.co m Email: [email protected] Web:www.mikrosize.com Email:[email protected]

 Open the catalog to page 1
iFlaw-100-2

•The body is lightweight and suitable for one-handed operation. • PD65W fast charge + 12 hours long battery life. • 5.0-inch IPS high-definition display with a brand new UI interface. • Support full-screen touch, quick gesture operation, virtual keyboard, easy to use • With DAC, AVG, automatic gain, peak memory, color half-span, B-scan and other professional functions. • Including Chinese and English switching, data export to SD card, online upgrade, screen capture and many other practical functions. • Mechanical manufacturing: Testing mechanical equipment components and large castings and forgings...

 Open the catalog to page 2
iFlaw-100-3

1. Power switch 2. Transmitting interface 4. B-scan trolley encoder interface ❶ 1. Mini USB data interface 3. SD card slot 2. Charging interface/Type-C data interface

 Open the catalog to page 3
iFlaw-100-4

1. Shuttle key 2. Status indicator light (Green light: Normal operation, Red light: Charging) 3. Menu key 4. Function keys/Shortcut keys 1. Basic Menu 2. Calibration Menu 3. Curve Menu 4. B-scan Menu 5. System Menu

 Open the catalog to page 4
iFlaw-100-5

1.Back Key: Long press to "restore" channel shortcut 2.Confirm Key: Long press to "create" a new channel shortcut 3.Decrease Key 4.Automatic Peak Adjustment Key: Automatically adjusts the echo amplitude, default is 80% 5.Peak Memory Key: Long press for gate expansion function 6.Full-screen Display Key: Long press for screenshot function 7.Freeze Key: Short press to hold the waveform on the screen. During freeze mode, long press to save. To continue testing, press the Freeze button again; Long press for recording function. 8.Increase Key

 Open the catalog to page 5
iFlaw-100-6

Diameter ZO.Onm Thickness 200.0mn l.Current Total Gain Value 2.Current Gain Step 3.Status Display 1.Parameter Menu 2.Measurement Value Display 3.Current Time and Battery Level Display

 Open the catalog to page 6
iFlaw-100-7

•The DAC curve includes RL (rejection line), SL (quantification line), and EL (evaluation line) High quantitative accuracy; •Adjustable detection sensitivity; • More precise defect localization; •The comparability of the results is strong; • Convenient quality control AVG Curve •AVG curve only supports the use of straight probes •Accurate quantification of defects • High detection sensitivity • Defect localization assistance •Good reproducibility of results •Widely applicable •The AVG curve can provide distance information between the defect and the probe. By measuring the arrival time of the...

 Open the catalog to page 7
iFlaw-100-8

B-Scan Image Only supports generating B-scan images in straight probe mode 2D image display; Accurately determine the depth position of the defect in the tested object; Defects will appear in different grayscale or brightness levels in the image, making it easier for inspectors to identify and judge; Wide applicability

 Open the catalog to page 8
iFlaw-100-9

Data Storage Set the USB flash drive mode on the instrument; connect it to the computer via the Type-C data cable interface, and you can use the software to edit the content of the inspection report results. PDF files can be generated.

 Open the catalog to page 9
iFlaw-100-10

Single or double gates can be set in the basic menu. Double gates can enhance the accuracy and flexibility of detection, improve detection efficiency, and facilitate data analysis and recording. Double gates can be flexibly set according to different inspection standards and workpiece characteristics. By adjusting the width, height, and position of the gates, they can adapt to defect detection of different sizes and shapes. Double gates can simultaneously monitor multiple areas, enabling quick location of potential defects. This allows flaw detection personnel to complete inspections of workpieces...

 Open the catalog to page 10
iFlaw-100-11

Technical Parameters Bandwidth Wave filter Sampling rate Hardware sampling rate 100MSPS, equivalent sampling rate 400MSPS Detection mode Full wave, positive half wave, negative half wave, RF, envelope Detection range 10 meters (longitudinal wave carbon steel),pace 100mm、10mm、0.1mm Pulse mode Sharp pulse, square wave, dual-square wave Pulse voltage Pulse width Emission damping Pulse frequency Automatic or manual, automatic range(200Hz-1KHz), manual range(0-10KHz) Probe channel 200 groups, supporting operations such as creating, previewing, deleting, renaming, overwriting, and restoring Gate alarm...

 Open the catalog to page 11
iFlaw-100-12

Probe (high-precision straight probe, angle probe) Probe line Power line User manual Warranty card

 Open the catalog to page 12

All Mikrosize catalogs and technical brochures

  1. IMS-20

    9  Pages

  2. iSurfa-100

    12  Pages

  3. iSurfa-520

    14  Pages

  4. iCoat-320

    12  Pages

  5. iLeeb-300

    13  Pages

  6. iFlaw-80

    12  Pages

  7. iShore-100

    12  Pages

  8. iCoat-310

    11  Pages

  9. MS-DF-20K

    11  Pages

  10. iStereo-211VT

    12  Pages

  11. iMetal-880B/BD

    11  Pages

  12. iMetal-530BD

    9  Pages

  13. iRocky-150CL

    14  Pages

  14. uRocky-150CM

    5  Pages

  15. uVicky-1A-2

    11  Pages

  16. MVicky-1000T

    13  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.