RPS-302 Features Various Sensing Ranges Adjustable Delay Controls Narrow Sensing Beam High Frequency Isolated Form C Relay Outputs Sealed Remote Transducers Small Electronic Controller The RPS-302 has 2 sealed, multiplexed transducers with independent range control adjustments, LED indicators, and form C relay outputs. This sensor also has a unique master and slave feature which enables many of the same units to be used within close proximity of one another without cross-talk interference. For example, if three sensors are needed in a close area, one sensor would be left as a master and the other two would be slaves. This is done by means of the X IN, X OUT, and GND connection on the board. One sensor (master) would send a signal by means of the X OUT and GND terminals. 5" Proximity Detection Proximity Detection Proximity detection is the detection of an object in a given range. The detection range of the RPS-302 is controlled by the "Range Control" potentiometers located on the front cover of the controller. Any object within the desired range is detected, while objects out of range are ignored. The detect point is independent of size, material, and reflectivity. Migatron Corporation - 1997 These would be connected to the X IN and GND terminals of the other two sensors (slaves). With the sensors connected in this way, all units would be transmitting and receiving at the same time. This then would prevent cross-talk and enable all three sensors, or all six transducers, to be used at the same time in close proximity of one another. There are also separate turn ON and turn OFF DELAY potentiometers provided for each transducer. All four DELAY controls are located along side the black module inside the enclosure box. The remote transducers allow for mounting of the sensor heads in cramped spaces while the controller is out of the way. The (2) independent and isolated form C relays furnish N.O. and N.C. outputs. This sensor, operates at a frequency of 222kHz for the 14" and 36" ranges and 150kHz for the 72" range. This sensor has a narrow sensing beam. Sensing ranges available for the RPS302 include 4" to 14", 5" to 36" and 8" to 72". Mounting flanges, LED indicators, ranging potentiometers, and 6-ft. transducer cables are included. Optional cable lengths are available.
Open the catalog to page 1Specifications: Operational Range: Adjustable 4" to 14" Adjustable 5" to 36" Adjustable 8" to 72" Power Input: Input Current: Ambient Temperature: Controller : Transducer Housing: Transducer: Metal Enclosure Galvanized Steel in 14" & 36", Plastic in 72" Silicone Rubber or Teflon Sensing Face Output: N.O., N.C. for each transducer Isolated Form C Relay .5 Amp Maximum at 120VAC Transducer Frequency: Adjustable Response Time: ON OFF Weight of Controller: 34.2 ounces Weight of Each Transducer: 2.2 ounces Master - Slave Connection Master Unit Slave Unit Figure: A - Angle of Tilt B - Beam Spread C...
Open the catalog to page 22 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
2 Pages
3 Pages
2 Pages
2 Pages
68 Pages