RL00S - 1

Model Number RL00S Bootstrap Compressor 2:1 Ratio Air Pressure Booster The Bootstrap Compressor is an air-driven, air pressure booster. It requires no electricity, cooling water, or air-line lubricator and is explosionproof. Shop air is fed to the inlet port through a filter, and is split into two streams inside the booster. One stream flows to the compressor portion of the unit and is boosted to higher pressure. The other stream drives the compressor portion, and is consumed during booster operation. The drive air stream is regulated to maintain the discharge pressure set by the external regulator handle. Drive air consumption is approximately 1/2 to 1 times the amount of pressure-boosted air. For example, if 2 scfm of high pressure air is required, the Bootstrap Compressor will need 3 to 4 scfm of shop air, and 1 to 2 scfm of that air will be vented through an exhaust silencer. For a given shop air pressure, Model RL00S can deliver high pressure air at any flow rate up to the maximum shown on the flow curves below. The pressure regulator enables the booster to adjust automatically to changes in high pressure air demand or shop air pressure. When there is no demand for high pressure air, the booster stalls at the discharge pressure set by the regulator and consumes no energy. When there is a need for high pressure air, the pressure drops which causes the booster to restart automatically. MODEL RL00S FEATURES A. Inlet pressure gauge B. Built-in pressure regulator 
 C. Discharge pressure gauge
 D. 1/4” FNPT inlet filter E. Exhaust Silencer F. 1/4” FNPT discharge port
 MODEL RL00S SPECIFICATIONS • Maximum 2 to 1 boost ratio Midwest Pressure Systems, Inc. 850 Transport Drive, Valparaiso, IN 46383 Phone 219-462-0070 M I D W E S T 2" Square PRESSURE www.midwestpressuresystems.com SY S T E M S • Capable of 100% duty cycle • Inlet pressure range of 15-150 psig • Discharge pressure range of 15-280 psig • Temperature range of 40-130˚F • Approximate weight of 6 pounds • Integral regulator controls discharg

Open the catalog to page 1
RL00S - 2

Model RL00S Flowrate vs Supply and Discharge Pressure Maximum Allowable Pressure of 280 psig Discharge Pressure in psig 130 psig supply air 110 psig supply air 90 psig supply air 120 70 psig supply air 80 Flowrate in scfm Use the curves above to determine the Model RL00S air pressure booster maximum discharge flowrate for a given set of operating conditions. In the example shown above, a maximum discharge pressure of 160 psig is desired and 90 psig supply air is available. MPS 160 psig line until it intersects with the Follow the 90 psig supply air curve. Draw a vertical line from the...

Open the catalog to page 2

All Midwest Pressure Systems catalogs and technical brochures

  1. R60S

    2 Pages

  2. R12S

    2 Pages

  3. R03S

    2 Pages

  4. R00S

    2 Pages

  5. RL12S-D

    2 Pages

  6. RL12S

    2 Pages

  7. RL03S-D

    2 Pages

  8. RL03S

    2 Pages

  9. 420TAAV090

    4 Pages

  10. 44SSV24-VC

    4 Pages

  11. 44AAV24

    4 Pages

  12. S42N5D

    2 Pages

  13. HH42

    4 Pages

  14. HH3040

    4 Pages

  15. HH2540

    4 Pages

  16. HL42

    4 Pages

  17. HL3040

    4 Pages

  18. HL2540

    4 Pages