HL42
4Pages

{{requestButtons}}

Catalog excerpts

HL42 - 1

HL42 series booster Air / Inert Gas Pressure Booster 1.5 HP 115V AC / 230V AC Electric motor 24/7 operation 40 - 100 psi gas inlet pressure 2,500 psi max gas discharge pressure 10,000 hours of seal life Air-cooled / Oil free Touchscreen control panel MPS MPS Midwest Pressure Systems, Inc. M I DWEST PRESSURE SY S T E M S 850 Transport Drive Valparaiso, IN 46383 www.midwestpressuresystems.com 2" Square

Open the catalog to page 1
HL42 - 2

Booster Specifications: HL42 series Gas Connections & dimensions HL42-1500 Stage 1 Bore diameter and stroke length Stage 2 Bore diameter and stroke length Gas displacement per cycle Overall dimensions (W x D x H) 0.038 cubic feet (1.08 liters) 16” x 27” x 50” (41 cm x 69 cm x 127 cm) Recommended fluid 3.5 Gallons Electrical Specifications Rated voltage Supply cable Power consumption Pressure, Temperature & Noise Specifications Gas supply pressure range Gas discharge pressure range 40 psig to 100 psig (2.8 bar to 6.9 bar) 500 psig to 1500 psig (35.5 barg to 103 barg) Ambient temperature range...

Open the catalog to page 2
HL42 - 3

Performance Data: HL42 The HL42 gas pressure boosters provide flow rates between 50 SCFH and 110 SCFH for the “1500” series unit and between 45 SCFH and 90 SCFH for the “2500” series unit depending on the gas supply pressure. Installing a regulator upstream of the booster allows the operator to set the desired flow rate. Example: A nitrogen generator is capable of delivering 99% nitrogen at 60 SCFH and 80 psig. However with an 80 psig supply the HL42-2500 booster will produce approximately 75 SCFH. 75 SCFH is more than the nitrogen generator is capable of providing so a loss in purity may...

Open the catalog to page 3
HL42 - 4

Touchscreen Control Panel: HL42 The HL42 gas pressure booster uses a touchscreen control panel. The touchscreen allows the operator to turn ON and OFF the system, view & change various operating parameters and review error codes. An example of the Home Screen is shown below along with a list of the viewable/modifiable parameters. Viewable Parameters Output Pressure The current discharge pressure of the system High Pressure Setting The pressure at which the system will automatically turn OFF (Modifiable by the operator) The pressure at which the system will automatically turn ON (Modifiable...

Open the catalog to page 4

All Midwest Pressure Systems catalogs and technical brochures

  1. R60S

    2 Pages

  2. R12S

    2 Pages

  3. R03S

    2 Pages

  4. R00S

    2 Pages

  5. RL00S

    2 Pages

  6. RL12S-D

    2 Pages

  7. RL12S

    2 Pages

  8. RL03S-D

    2 Pages

  9. RL03S

    2 Pages

  10. 420TAAV090

    4 Pages

  11. 44SSV24-VC

    4 Pages

  12. 44AAV24

    4 Pages

  13. S42N5D

    2 Pages

  14. HH42

    4 Pages

  15. HH3040

    4 Pages

  16. HH2540

    4 Pages

  17. HL3040

    4 Pages

  18. HL2540

    4 Pages