HH42 - 1

HH42 series booster Air / Inert Gas Pressure Booster 3.0 HP, AC Electric motor 24/7 operation 50 - 100 psi gas inlet pressure 2,500 psi max gas discharge pressure 10,000 hours of seal life Air-cooled / Oil free MPS Midwest Pressure Systems, Inc. M I DWEST PRESSURE SY S T E M S Touchscreen control panel 850 Transport Drive Valparaiso, IN 46383 www.midwestpressuresystems.com 2" Square

Open the catalog to page 1
HH42 - 2

Booster Specifications: HH42 series Gas Connections & dimensions HH42-1500 Stage 1 Bore diameter and stroke length Stage 2 Bore diameter and stroke length Gas displacement per cycle Overall dimensions (W x D x H) 0.038 cubic feet (1.08 liters) 18” x 27” x 50” (46 cm x 69 cm x 127 cm) Recommended fluid 3.5 Gallons Electrical Specifications Rated voltage Power consumption Max current Supply cable & Supplied by customer Pressure, Temperature & Noise Specifications Gas supply pressure range Gas discharge pressure range 50 psig to 100 psig (3.4 bar to 6.9 bar) 500 psig to 1500 psig (35.5 barg to...

Open the catalog to page 2
HH42 - 3

Performance Data: HH42 The HH42 gas pressure boosters provide flow rates between 120 SCFH and 220 SCFH for the “1500” series unit and between 100 SCFH and 180 SCFH for the “2500” series unit depending on the gas supply pressure. Installing a regulator upstream of the booster allows the operator to set the desired flow rate. Example: A nitrogen generator is capable of delivering 99% nitrogen at 120 SCFH and 80 psig. However with an 80 psig supply the HH42-2500 booster will produce approximately 145 SCFH. 145 SCFH is more than the nitrogen generator is capable of providing so a loss in purity...

Open the catalog to page 3
HH42 - 4

Touchscreen Control Panel: HH42 The HH42 gas pressure booster uses a touchscreen control panel. The touchscreen allows the operator to turn ON and OFF the system, view & change various operating parameters and review error codes. An example of the Home Screen is shown below along with a list of the viewable/modifiable parameters. Viewable Parameters Output Pressure The current discharge pressure of the system High Pressure Setting The pressure at which the system will automatically turn OFF (Modifiable by the operator) The pressure at which the system will automatically turn ON (Modifiable...

Open the catalog to page 4

All Midwest Pressure Systems catalogs and technical brochures

  1. R60S

    2 Pages

  2. R12S

    2 Pages

  3. R03S

    2 Pages

  4. R00S

    2 Pages

  5. RL00S

    2 Pages

  6. RL12S-D

    2 Pages

  7. RL12S

    2 Pages

  8. RL03S-D

    2 Pages

  9. RL03S

    2 Pages

  10. 420TAAV090

    4 Pages

  11. 44SSV24-VC

    4 Pages

  12. 44AAV24

    4 Pages

  13. S42N5D

    2 Pages

  14. HH3040

    4 Pages

  15. HH2540

    4 Pages

  16. HL42

    4 Pages

  17. HL3040

    4 Pages

  18. HL2540

    4 Pages