  • Performance: Nominal Flux of 72,600 lm and Net Flux of 67,009 lm with Power Absorption at 660 W.
  • Optoelectronics: Utilizes CREE XP-G LEDs on an MPCB 1.6 mm circuit board. CRI options are 70, 80, and 90. Luminous efficiency loss is less than 1% per annum. Available color temperatures are 3,000K, 4,000K, and 5,000K. Lumen maintenance is L90 at 63,000 hours and L70 at over 100,000 hours.
  • Optics: Features a TIR Lens Array with IP67 system treatment and anti-yellowing properties. Available optics include S1, S2, S3, E1, and FH. Each module contains 32 LEDs, with a total of 4 modules.
  • Luminaire Body: Constructed from stainless steel with powder-painted metal coating and extruded aluminum heatsinks. The bracket is a central bolt of 20mm. The luminaire weighs 23 kg and is designed for installation heights between 25m to 50m with a 360° tilt adjustment. Dimensions are 442L x 416W x 240H mm with a windage area of 0.067 m².
  • Electronics: Voltage input range is 90-305 VAC at 50-60Hz with a power factor of 0.95. Mean time to failure is 200,000 hours. Dimming functions include 1-10V and DALI. Surge protection is rated at 15kA, IEEE C62.41.2. The product is classified under Location Category C High and Insulation Class IEC Class 1. It has an IP Rating of IP67, with auto-recovery short circuit protection and overheat protection that reduces output current. The relative humidity range is 0% - 94%, and the operating temperature range is -40°C to +70°C.
Product Description

The product is a highly efficient LED floodlight designed for sports and large area lighting. It features electronic LED control gear driving 128 LEDs at 1.5A with multiple photometric distributions. It offers IP67 and Class I protection with 15 kA surge protection. The body is made of recyclable stainless steel, and the optic enclosure uses proprietary PMMA weather-proof lenses. It includes a fully reversible mounting bracket.

Normative References
  • EN 60598-1: 2015 - General requirements and tests for luminaires.
  • EN 60598-2-5: 2015 - Particular requirements for floodlights.
  • EN 62031: 2008 + A2:2015 - Safety specifications for LED modules.
  • EN 60598-2-3: 2003 + A1: 2011 - Requirements for road and street lighting luminaires.
  • EN 62493: 2015 - Assessment of lighting equipment related to human exposure to electromagnetic fields.
  • EN 60529: 1992 + A2: 2013 - Degrees of protection provided by enclosures (IP Code).
  • IEC 60068-2-52: 1996 - Environmental test for salt mist cyclic.
  • EN 55015: 2013 + A1: 2015 - Limits and methods of measurement of radio disturbance characteristics.
  • EN 61547: 2009 - EMC immunity requirements for general lighting equipment.
  • EN 61000-3-2: 2014 - Limits for harmonic current emissions.
  • EN 61000-3-3: 2013 - Limitation of voltage changes, voltage fluctuations, and flicker.
  • EN 61643-11: 2012 - Requirements and test methods for low-voltage surge protective devices.
  • IEEE C62.41.2-2002 - Recommended practice on characterization of surges in low-voltage AC power.
Ordering Information

Product family includes various power, optic, CCT, bracket, control system, body type, and connector options. Example ordering code: M-03-S1-A-70-EU-10-S-T-T-02.

See more

Catalog excerpts

Modus 600-1

Modus 600 Highly efficient LED floodlight designed specifically for sport and large area lighting. Electronic, LED control gear driving 128 LEDs at I.5A with multiple photometric distributions. IP67, Class I protection with 15 l<A Surge Protection. Body: recyclable, stainless steel. Optic Enclosure: proprietary PMMA Weather-proof lenses. Fully reversible mounting bracket. C€ LED IP67 ® Technical data Performance Nominal Flux: 72,600 Im Optoelectronics LED Type: Circuit Board: CRI: Luminous Eff Loss: Colour Temperature: Lumen Maintenance L90: Lumen Maintenance L70: Electronics Voltage input range: Power Factor: Mean time to Failure: Dimming Function: Surge Protection: Insulation Class: IP Rating: Short Circuit Protection: Over Heat Protection: Rel. Humidity Range: Operating Temp: 90-305 VAC 50-60Hz 0.95 200,000 hrs l-l0V / DALI I5kA, IEEE C62.4I.2 Location Category C High IEC Class l IP 67 Auto-recovery Drops output current 0% - 94% -40°C up to +70°C TIR Lens Array IP67, Anti-yellowing Sl / S2 / S3 / El / FH 32 4 Luminaire Body Structure: Metal coating: Heatsinks: Bracket: Weight: Installation height: Installation angle: Dimensions: Windage Area: Optics Secondary Lens: System Treatment: Available optics: No of LEDs / module: No of modules: Stainless Steel Powder painted Extruded Aluminium Central Bolt 20mm 23 kg 25m to 50m Tilt Adjustment 360° 442L x 4I6W x 240H mm 0.067 m2 Midstream Lighting Ltd, l Chesham Street, London SWlX 8ND, UK Tel +44 207 584 83l0 Email [email protected] www.midstreamlighting.com Normative references EN 60598-1: 2015 - Luminaires - Part 1: General requirements and tests EN 60598-2-5: 2015 Luminaires - Part 2-5: Particular requirements - Floodlights EN 62031: 2008 + A2:20l5 - LED modules for general lighting - Safety specifications EN 60598-2-3: 2003 + Al: 2011 - Luminaires - Part 2-3: Particular requirements -Luminaires for road and street lighting EN 62493: 2015 Assessment of lighting equipment related to human exposure to electromagnetic fields EN 60529: 1992 + A2: 2013 - Degrees of protection provided by enclosures (IP Code) IEC 60068-2-52: 1996 Environmental test - Part 2: Tests - Test Kb - Salt mist cyclic (sodium chloride solutions) EN 55015: 2013 + Al: 2015 - Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment EN 6l547: 2009 - Equipment for general lighting purposes - EMC immunity requirements EN 6l000-3-2: 20l4 - Electromagnetic compatibility (EMC) - Part 3-2: Limits -Limits for harmonic current emissions (equipment input current < l6 A per phase) EN 6l000-3-3: 20l3 - Electromagnetic compatibility (EMC) - Part 3-3: Limits -Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current < l6 A per phase and not subject to conditional connection EN 6l643-ll: 20l2 - Low-voltage surge protective devices. Part ll: Surge protective devices connected to low-voltage power systems - Requirements and test methods IEEE C62.4l.2-2002 - Recommended practice on characterization of surges in low-voltage AC power

 Open the catalog to page 1
Modus 600-2

FH (Floodlight high asymmetry) Ordering codes Product Family Power Optic CCT CRI Voltage Control system Body Type Bracket Connector 06 S2 B (4000K) 80 US (347-480 AC) DA (DALI) H (High Heat ) S (Suspension) 02 (Ext IP68 Connector) 09 S3 C (3000K) 90 CA (100-240 AC) CW (Custom Wireless) C (Short) 12 E1 D (5700K) XC (Custom) CL (Custom Line) P (Pole) FH Example: M-03-SI-A-70-EU-I0-S-T-T-02 Note: Specifications are subject to change without notice i/T MIDSTREAM Midstream Lighting Ltd, 1 Chesham Street, London SWIX 8ND,...

 Open the catalog to page 2

All Midstream Lighting catalogs and technical brochures

  1. Modus R800

    2  Pages

  2. Atlas 600

    2  Pages

  3. TITAN 220

    2  Pages

  4. TITAN 320

    2  Pages

  5. Modus 300

    2  Pages

  6. TITAN 720

    2  Pages

  7. TITAN 560

    2  Pages

  8. TITAN 420

    2  Pages

  9. TITAN 160

    2  Pages

  10. Modus R1200

    2  Pages

  11. Atlas 300

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.