MIDAC S.p.A. CERTIFIED MANAGEMENT SYSTEM ISO 9001 - ISO 14001 - ISO 45001 Via A. Volta, 2 - Z.I. - 37038 SOAVE (Verona) ITALIA - Tel. +39 045 6132 132 - Fax +39 045 6132 133 Codice Fiscale e C.C.I.A.A. VR 02103180242 - Partita Iva IT 02103180242 - R.E.A. VR n.225330 Iscrizione C.C.I.A.A. VR: R.P.A. IT09060P00000483 - R.A.E.E. IT21020000012757 Capitale Sociale EURO 20.000.000,00 i.v. – e-mail: [email protected] – www.midacbatteries.com Information for the safe handling of Lead-Acid batteries The Lead-acid battery is not a “substance”, a mixture or a dangerous “preparation” according to Regulation (EC) no. 1907/2006, it is an “article”; no substance is intended to be released during the utilization. There is no obligation, therefore, to provide a safety data sheet in accordance with the Regulation (EC) no. 1907/2006, article 31 and related Annex II (as amended by Regulation (EU) 2020/878). This document, however, is made available to recipients and consumers in compliance with the provisions of Regulation (EC) no. 1907/2006, article 33. 1. Article identification and manufacturer 1.1 Article: Lead-acid battery 1.2 Relevant uses: Starter batteries for cars and vehicles Industrial batteries for motive power and standby applications 1.3 Manufacturer: MIDAC S.p.A. Via Alessandro Volta, 2 – 37038 Soave (VR) - Italy Telephone +39 045.61.32.132 Fax +39 045.61.32.133 E-mail address of the competent person responsible for the present document: [email protected] 1.4 Emergency telephone numbers: ITALY: Pavia - Poison Center, +39 0382 24444 OTHER COUNTRIES: Poison control national center 2. Safety warnings and hazards Using correctly intact battery, do not exist special hazards to humans and the environment. Explosion Hazard: An explosive mixture of oxyhydrogen gas occurs when charging batteries. Therefore, do not smoke, do not use naked flames or fires, and do not cause sparks in the immediate vicinity of the battery. Avoid short-circuits in the battery terminals. Always use anti-static materials when cleaning. Do not store the battery in sealed containers; always store in a cool and well-ventilated area away from direct sunlight and heat sources. Corrosive Hazard: Lead-acid batteries contain sulphuric acid diluted in a water solution which is corrosive and harmful to skin and eyes. Specific gravity 1.22 ÷ 1.30 kg/l (30 – 40 %). SdS-Pb-EN rev. 13 – 13/02/2024 1 di 7 Direzione e co
Open the catalog to page 1CERTIFIED MANAGEMENT SYSTEM ISO 9001 - ISO 14001 - ISO 45001 Via A. Volta, 2 - Z.I. - 37038 SOAVE (Verona) ITALIA - Tel. +39 045 6132 132 - Fax +39 045 6132 133 Codice Fiscale e C.C.I.A.A. VR 02103180242 - Partita Iva IT 02103180242 - R.E.A. VR n.225330 Iscrizione C.C.I.A.A. VR: R.P.A. IT09060P00000483 - R.A.E.E. IT21020000012757 Capitale Sociale EURO 20.000.000,00 i.v. - e-mail: [email protected] - www.midacbatteries.com Lead-acid batteries can contain a considerable amount of energy, which may be a source of high electrical current and a severe electrical shock in the event of a short...
Open the catalog to page 2MIDAC S.p.A. CERTIFIED MANAGEMENT SYSTEM ISO 9001 - ISO 14001 - ISO 45001 Via A. Volta, 2 - Z.I. - 37038 SOAVE (Verona) ITALIA - Tel. +39 045 6132 132 - Fax +39 045 6132 133 Codice Fiscale e C.C.I.A.A. VR 02103180242 - Partita Iva IT 02103180242 - R.E.A. VR n.225330 Iscrizione C.C.I.A.A. VR: R.P.A. IT09060P00000483 - R.A.E.E. IT21020000012757 Capitale Sociale EURO 20.000.000,00 i.v. – e-mail: [email protected] – www.midacbatteries.com a) Inhalation: Probability of exposure by inhalation is low, however in the event this should occur move the injured person away from the contaminated area...
Open the catalog to page 3MIDAC S.p.A. CERTIFIED MANAGEMENT SYSTEM ISO 9001 - ISO 14001 - ISO 45001 Via A. Volta, 2 - Z.I. - 37038 SOAVE (Verona) ITALIA - Tel. +39 045 6132 132 - Fax +39 045 6132 133 Codice Fiscale e C.C.I.A.A. VR 02103180242 - Partita Iva IT 02103180242 - R.E.A. VR n.225330 Iscrizione C.C.I.A.A. VR: R.P.A. IT09060P00000483 - R.A.E.E. IT21020000012757 Capitale Sociale EURO 20.000.000,00 i.v. – e-mail: [email protected] – www.midacbatteries.com 8. Exposure control/personal protection Except for safety shoes, all other PPE (personal protective equipment) are for protection against exposure to electrolyte...
Open the catalog to page 4MIDAC S.p.A. CERTIFIED MANAGEMENT SYSTEM ISO 9001 - ISO 14001 - ISO 45001 Via A. Volta, 2 - Z.I. - 37038 SOAVE (Verona) ITALIA - Tel. +39 045 6132 132 - Fax +39 045 6132 133 Codice Fiscale e C.C.I.A.A. VR 02103180242 - Partita Iva IT 02103180242 - R.E.A. VR n.225330 Iscrizione C.C.I.A.A. VR: R.P.A. IT09060P00000483 - R.A.E.E. IT21020000012757 Capitale Sociale EURO 20.000.000,00 i.v. – e-mail: [email protected] – www.midacbatteries.com a) FLOODED LEAD-ACID BATTERIES By land (ADR/RID - road/railway): Proper Shipping Name: BATTERIES, WET, FILLED WITH ACID electric storage UN2794 8 Not assigned...
Open the catalog to page 5MIDAC S.p.A. CERTIFIED MANAGEMENT SYSTEM ISO 9001 - ISO 14001 - ISO 45001 Via A. Volta, 2 - Z.I. - 37038 SOAVE (Verona) ITALIA - Tel. +39 045 6132 132 - Fax +39 045 6132 133 Codice Fiscale e C.C.I.A.A. VR 02103180242 - Partita Iva IT 02103180242 - R.E.A. VR n.225330 Iscrizione C.C.I.A.A. VR: R.P.A. IT09060P00000483 - R.A.E.E. IT21020000012757 Capitale Sociale EURO 20.000.000,00 i.v. – e-mail: [email protected] – www.midacbatteries.com By sea (IMDG Code): Proper Shipping Name: BATTERIES, WET, NON SPILLABLE electric storage UN2800 8 Not assigned P003 F-A, S-B No. 8 IMDG UN No.: IMDG Hazard...
Open the catalog to page 6MIDAC S.p.A. CERTIFIED MANAGEMENT SYSTEM ISO 9001 - ISO 14001 - ISO 45001 Via A. Volta, 2 - Z.I. - 37038 SOAVE (Verona) ITALIA - Tel. +39 045 6132 132 - Fax +39 045 6132 133 Codice Fiscale e C.C.I.A.A. VR 02103180242 - Partita Iva IT 02103180242 - R.E.A. VR n.225330 Iscrizione C.C.I.A.A. VR: R.P.A. IT09060P00000483 - R.A.E.E. IT21020000012757 Capitale Sociale EURO 20.000.000,00 i.v. – e-mail: [email protected] – www.midacbatteries.com Where applicable, to make reference to normative following: - D. Lgs. 152/2006 and following modifications; - D. Lgs. 81/2008 and following modifications;...
Open the catalog to page 74 Pages
8 Pages