1. Catalogs
  2. MICROTRAC
  3. TURBISCAN RANGE
video corpo

TURBISCAN RANGE
1 /24Pages

TURBISCAN RANGE

TURBISCAN RANGE
1 /24Pages

Catalog excerpts

TURBISCAN RANGE-1

aVERDER company SHELF-LIFE & DISPERSIBILITY ANALYZERS THE WORLD REFERENCE STABILITY ANALYZER BY STATIC MULTIPLE LIGHT SCATTERING

 Open the catalog to page 1
TURBISCAN RANGE-2

Retsch Technology catalysis inves- commercial laser adsorption instru- tigation system BLUEWAVE laser with optional SYNC: laser diff- diffractor that uses MicrotracBEL into lyzer, MICROTRAC camera system. real blue lasers for surement system, MICROTRAC under highest resolution Verder Scientific. into MICROTRAC.

 Open the catalog to page 2
TURBISCAN RANGE-3

Three Centers of Excellence MICROTRAC: A SINGLE-SOURCE SOLUTION PROVIDER FOR PARTICLE CHARACTERIZATION PARTICLE SIZE & SHAPE FOR PARTICLE ANALYSIS Size & Distribution COLLOIDS AND FORMULATIONS CHARACTERIZATION Particle size Zeta potential Stability & Shelf-Life MATERIALS CHARACTERIZATION Surface Area & Pore size Our expertise in particle size distribution and shape When working with colloids or formulations, the We offer advanced solutions for measuring analysis ensures optimal product quality control and three main parameters to consider are particle surface area, porosity, and catalytic properties...

 Open the catalog to page 3
TURBISCAN RANGE-4

TURBISCAN RANGE THE WORLD LEADER IN SHELF-LIFE AND STABILITY ANALYSIS I SAVE TIME Up to 1,000 times faster compared to a conventional visual stability test I DETECT & QUANTIFY Sedimentation, phase separation, aggregation, coalescence, coagulation, creaming… All destabilizations are detected and quantified I OBJECTIVE & RELIABLE Instrumental method, no dilution, no external stress, measure the sample as is – analysis you can trust I WIDE RANGE OF APPLICATIONS Suspensions, emulsions, foams, from low to high concentrations (10-4 - 95% v/v), opaque, clear, coloured samples, from nano to macro (10...

 Open the catalog to page 4
TURBISCAN RANGE-5

STATIC MULTIPLE LIGHT SCATTERING (SMLS) CUTTING-EDGE STABILITY AND DISPERSIBILITY TECHNOLOGY COUPLED WITH SMART DATA ANALYSIS Turbiscan is based on the Static Multiple Light Scattering (SMLS) technology, the most suitable method to characterize Light source liquid dispersions, directly, in their native state. In most emulsions, suspensions and formulations the concentrations are too high to be analyzed “as is” with light scattering and their characterization requires dilution or mechanical stress, altering their state and structure. SMLS offers the ability to investigate the dispersion state...

 Open the catalog to page 5
TURBISCAN RANGE-6

HOW DOES IT WORK SCANNING READING HEAD Moving measurement head TURBISCAN RANGE STATIC MULTIPLE LIGHT SCATTERING (SMLS) Light source mean particle size particle concentration cell radius extinction efficiency HIGH RESOLUTION TO THE SMALLEST VARIATION OF PARTICLE SIZE VARIATION AND MIGRATION Backscattering (BS) and Transmission (T) intensities are directly I Sensitive to the slightest variation of particle size SMLS consists of sending photons (NIR light source, 880nm) into the sample. related to particle size (d) and particle concentration (ϕ) and are These photons, after being scattered many...

 Open the catalog to page 6
TURBISCAN RANGE-7

STATIC MULTIPLE LIGHT SCATTERING (SMLS) DATA REPRESENTATION DESTABILIZATION DETECTION Scans are overlayed on the same graph and in function of In the case of destabilization, deviations in scans are detected as a function of sample height. Due to the high sensitivity of the SMLS technology, sample height. Each scan has a specific colour from blue - first destabilizations are detected in their very early stage and up to 1,000 times faster than visual observation. scan to red - last scan to easily understand signal variations in function of time. Particle size increase Particle size increase

 Open the catalog to page 7
TURBISCAN RANGE-8

SHELF-LIFE AND DISPERSIBILITY ANALYZERS | TURBISCAN TURBISCAN SMART ANALYSIS TURBISCAN STABILITY INDEX - TSI PARTICLE SIZE & DISTRIBUTION Turbiscan Stability Index (TSI) sums all the signal variations along the entire sample height and therefore, takes into account all destabilizations occurring. Thanks to the TSI, sample comparison is easy as the higher the TSI, the lower the stability. The key points of the TSI: it is “one-click” and fully automatic, operator-independent, and does not require any data input. The TSI is used in R&D labs for formula stability comparison and optimization, Quality...

 Open the catalog to page 8
TURBISCAN RANGE-9

SHELF-LIFE & DISPERSIBILITY ANALYZER TURBISCAN THE BEST TECHNOLOGY FOR FAST & NON-INVASIVE STABILITY ANALYSIS

 Open the catalog to page 9
TURBISCAN RANGE-10

TEMPERATURE RANGE TURBISCAN STABILITY INDEX PARTICLE SIZE DISTRIBUTION THE WORLD REFERENCE STABILITY ANALYZER TURBISCAN LAB allows fast and sensitive identification of destabilization mechanisms (creaming, sedimentation, flocculation, coalescence, …). A temperature-controlled measurement chamber allows stability monitoring at specific storage temperatures or acceleration of the destabilization process with a temperature increase up to 60 °C. TURBISCAN LAB can be used in both R&D and QC labs for the development and routine control of raw materials and final product formulations. The Turbiscan...

 Open the catalog to page 10
TURBISCAN RANGE-11

3-SAMPLE MACROSCOPIC & COLLOIDAL STABILITY ANALYZER FEATURES Static Multiple Light Scattering (SMLS) Technology 3 independent sample positions Temperature range: from 20 °C to 60 °C Accelerated destabilization detection up to 1,000x TURBISCAN TRILAB is a multi-sample stability analyzer based on the SMLS technology. It enables fast and reliable shelf-life studies of formulations (emulsions, suspensions, foams). faster than visual observation Real stability: no dilution (10 -4 up to 95% v/v) – No mechanical stress Destabilization Quantification: migration velocity, The TRILAB offers several advantages...

 Open the catalog to page 11
TURBISCAN RANGE-12

TURBISCAN TOWER 6-SAMPLE MACROSCOPIC & COLLOIDAL STABILITY ANALYZER TURBISCAN TOWER is the flagship product of the Turbiscan of the SMLS technology, but it also enables accelerated stability range, for fast, precise, and quantitative stability measurement tests by varying the temperature from 4 °C to 80 °C and follows of formulations (emulsions, suspensions, foams). ISO recommendations (ISO/TR 13097:2013, ISO/TR 18811:2018). The stability measurement is done with a non-invasive and non-de- The TOWER offers 6 independent measurement positions allow- structive technique, preserving the integrity...

 Open the catalog to page 12

All MICROTRAC catalogs and technical brochures

  1. BELCAT II

    12  Pages

  2. BELPYCNO L

    4  Pages

  3. BELSORP MAX X

    12  Pages

  4. BELSORP MINI X

    12  Pages

  5. CAMSIZER X2+

    24  Pages

  6. CAMSIZER 3D

    20  Pages

  7. SYNC

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.