Catalog excerpts
PARTICLE SIZE & SHAPE ANALYZER UNIQUE, PATENTED 3D PARTICLE CHARACTERIZATION WITH DYNAMIC IMAGE ANALYSIS
Open the catalog to page 1PARTICLE CHARACTERIZATION AT ITS BEST Microtrac MRB is your preferred partner for the comprehensive characterization of particulate systems. We provide our customers with advanced technologies to obtain consistently reliable results. Innovation and quality form the basis of our business. As part of the Verder Scientific Group we provide worldwide support through a network of subsidiaries and distributors.
Open the catalog to page 2Particle Size & Shape 1 nm THREE PILLARS OF EXCELLENCE Dynamic Image Analysis Dynamic Light Scattering Surface & Porosity NANOTRAC Series Laser Diffraction Static Image Analysis BELSORP & BELPORE product lines Microtrac MRB offers three product lines with centers of excellence on three continents. I Scattered Light Analysis Microtrac MRB is a leading supplier of laser dif- With the CAMSIZER series, Microtrac MRB pro- Specific surface, BET value and porosity of fraction systems (static light scattering), a versa- vides high-quality systems for the measure- powders are analyzed by gas...
Open the catalog to page 3THE MOST POWERFUL DYNAMIC IMAGE ANALYSIS CAMSIZER 3D combines all the advantages of dynamic image analysis (ISO 13322-2) in a completely redesigned measuring system, setting new standards in the characterization of bulk solids. Particle Size & Shape Analyzer CAMSIZER 3D Patented 3D analysis with “Particle Tracking” I Unique 3D Analysis Thanks to the extended field of view and long drop distance, each particle is analyzed up to 30 times in different orientations, making the actual threedimensional particle morphology accessible for analysis. The evaluation of the “3D tracks” also provides...
Open the catalog to page 4PARTICLE SIZE AND SHAPE ANALYZER CAMSIZER 3D PATENTED METHOD FOR THE DETERMINATION OF PARTICLE MORPHOLOGY
Open the catalog to page 5Length Flow of particles Thickness Vibratory feeder UNIQUE TRACKING METHOD DETECTS THE TRUE MORPHOLOGY The CAMSIZER 3D utilizes a funnel, vibrating various shape descriptors. The software auto- I the largest value of all length measurements feed chute, LED strobe backlighting, powerful matically aligns the images for viewing, with within a particle track is the “3D length” of high-speed cameras, and sophisticated soft- up to 30 images per particle. This creates a ware to perform the measurements. “particle track”, a sequence of images of the I the largest value of all width measurements...
Open the catalog to page 63D Analysis is particularly advantageous for “mapping” of one image to another. Each indi- particles that are supposed to have a specific vidual image is treated as a new, independent shape like spheres, rods (extrudates), lenses measurement event. The true length, width, or ellipsoids (“rugby-ball”-shape). With the thickness, and shape is obscured by this. 3D tracking technology, each particle inevita- Rather, the “length” measured in 2D mode is Suitable for irregularly shaped material, natural products bly shows a wide variety of projections, which a mixture between true 3D length and...
Open the catalog to page 7DUAL CAMERA TECHNOLOGY EXTREMELY WIDE MEASURING RANGE WITH DUAL CAMERA TECHNOLOGY Microtrac MRB’s unique dual camera technology ing a size range of more than three orders of is a landmark in the development of Dynamic 9 megapixel ZOOM camera Image Analysis. By simultaneously employing 5 megapixel BASIC camera two cameras with different magnifications, ex- This arrangement resolves a significant draw- Calibration within a few seconds with certified reference objects tremely wide dynamic measuring ranges are back of many image analysis systems that em- achieved. This is accomplished without...
Open the catalog to page 8Compared to previous CAMSIZER models the CAMSIZER 3D features a significantly higher camera resolution and frame rate by employing a ZOOM camera with 9 megapixels and a BASIC camera with 5 megapixels at a frame rate of up to 250 fps. This allows superior image quality and particle detection, for all coarse and fine samples. Broad and narrow distributions are measured with the same accuracy and precision. The image width of the ZOOM camera is the same as that of the BASIC camera, which ensures excellent reproducibility of the measurement results within a short measurement time. MEASUREMENT...
Open the catalog to page 9EVERYTHING IN VIEW FROM START TO FINISH I Intuitive operation I Clear arrangement of workspaces I User-defined report templates I Comparison of measurement results at a glance I Newly designed “Particle Viewer” workspace I Consistent measurement conditions through SOPs I Automatic testing of product specifications I Different user levels I LIMS connection I 21 CFR part 11 compatible version availabl
Open the catalog to page 10changes. After the analysis, the recorded particle Image Analysis provides a wealth of information images are available in the new “Particle Viewer” about the sample material at hand. The powerful workspace. This makes subsequent evaluation, DIMENSIONS software records dozens of pa- which goes beyond pure routine analysis, ex- rameters on each individual particle and pres- tremely convenient. ents the results in a clear, standard-compliant measurement report that can be adapted to individual needs. played for each individual particle. By using custom filters, particles with specific...
Open the catalog to page 11APPLICATIONS Many properties of bulk solids, such as flowability, dissolution behavior, filtering properties, reactivity, abrasiveness or even taste are decisively influenced by the particle size. Therefore, the determination of particle size distributions is widely used in many sectors and industries and is routinely employed for quality control. The time-consuming and error-prone sieve analysis is still widely used but is increasingly being replaced by dynamic image analyzers of the CAMSIZER series. High sample throughput, robustness and automation capability of this technique ensure...
Open the catalog to page 12PRECISE LENGTH MEASUREMENT EXTRUDATES With the patented 3D particle measurement, the length distribution of extrudates can be dePercent by volume (%) termined accurately. A rod-shaped ceramic extrudate with a length of 6-8 mm was measured in 3D mode, in 2D mode and with a caliper. The result shows that the 3D length corresponds to the result of the caliper, but the 2D length gives a distribution that is “too short”. Thus, the 3D im- age analysis is as accurate as the caliper measurement but characterizes a significantly larger number of particles in a fraction of the time. IDENTIFICATION OF...
Open the catalog to page 13All MICROTRAC catalogs and technical brochures
-