Overview: The document describes a Motor Stator Testing System designed to meet international standards for motor testing. It emphasizes program control and analysis to reduce human error and misjudgment, offering a user-friendly editing environment and the ability to test multiple items simultaneously.
Key Features:- RS232 interface for communication.
- Non-destructive analysis through waveform comparison for interlayer short circuits.
- Capability to store up to 100 test files with password protection.
- Fast testing speed to save time and improve efficiency.
- Switchable interface between Chinese and English.
Standard Accessories:- Power cable, electronic user manual CD, high-voltage cable assembly, RCA connector, temperature probe, RS-232 connection cable, control cable (25F-25F), foot switch.
Optional Accessories:- Custom test fixtures, Motor Link Software for computer connection.
Specifications:- DC Resistance: 0.1mΩ to 100kΩ
- Insulation Resistance: 1MΩ to 9.9GΩ
- High Voltage Leakage Current: 0.1mA to 10.0mA
- Interlayer Short Circuit Pulse Voltage: 200V to 5000V
- Inductance: 0.01nH to 100kH
Measurement Details:- 8 channels for measurement points.
- PASS/FAIL indication through display and sound.
- Custom test fixtures produced as per testing needs.
- Power requirements: 90 ~ 132Vac or 198 ~ 264Vac (switchable).
- Storage: Flash Memory for up to 100 groups.
- Operating Environment: Temperature 10℃ ~ 40℃, Humidity 20 ~ 90%RH.
Model Specifics:- Model 6905: Dimensions 435x145x522 mm, Weight 12.5 Kg, LCD 128x64 resolution.
- Model 6910: Dimensions 435x190x522 mm, Weight 11 Kg, LCD 320x240 resolution.
Measurement Data:- DC Resistance (Model 6910): Range 0.1mΩ ~ 100kΩ with four-wire measurement, Stability Low Resistance: ±(0.2% ± 1mΩ), High Resistance: ±0.1%.
- Withstand Voltage: AC 0.1kV ~ 5kV, DC 0.1kV ~ 6kV, Leakage Current AC 0 ~ 10mA, DC 0 ~ 5mA.
- Insulation Resistance: Voltage 100V ~ 1000V ±5%, Range 1MΩ ~ 9.9GΩ.
- Inter-turn Short Circuit: Voltage 0.2kV ~ 5kV ±2%, Measures waveform area, area difference, jitter count, comparison, corona count.
Additional Equipment:- 6420 LCR Meter: Frequency 20Hz ~ 1MHz, AC Test Signal Level 10mV ~ 2Vrms.
See more