1. Catalogs
  2. Microtech Gefell GmbH
  3. SIS 190 double english

SIS 190 double english
1 /3Pages

SIS 190 double english

SIS 190 double english
1 /3Pages

Catalog excerpts

SIS 190 double english-1

NEW - SIS 190 double Customer Benefit - Measurements without Interruption The sound intensity probe SIS 190 double allows a simultaneous sound intensity measurement in a very large frequency range. For this purpose an arrangement of one one-dimensional 1/2" sound intensity probe and one onedimensional 1/4" sound intensity probe is formed. Due to its two-channel technology each individual Sound Intensity Probe makes it possible not only to measure sound pressure levels but also to record the sound pressure gradient which is needed to calculate the sound intensity. The SIS 190 double consists of the Measuring Microphone Capsules Pairs MK 290 E (2x MK 222 E) and MK 390 E (2x MK 301 E) with matched phase response and frequency response. Due to the use of the 1/4” Measuring Microphone Preamplifiers MV 310, sound field distortions (shadowing and diffractions) are minimal. The distance between the microphone pairs is defined by spacers (6 mm, 50 mm). These enable measurements in a frequency range between 35 Hz and 12 kHz. The quality of conformance between the microphone pairs with regard to their transforming functions is measured in compliance with DIN EN 61043 and documented as Minimum pressure-residual intensity index for probes. Each microphone capsule pair comes with a measuring protocol. It shows the tolerance limits for class 1 probes. SIS 190 double, IEPE*/ICP , Measuring microphone preamplifiers 1/4" MV 310, Measuring microphone capsule pair 1/2" MK 290 E, Measuring microphone capsule pair 1/4" MK 390 E, 2 Adapter A 69.1 1/2"-1/4", Spacer 1/2" 50 mm, Spacer 1/4" 6 mm, Output 10-pin LEMO, connects to a handle, Case in aluminium

 Open the catalog to page 1
SIS 190 double english-2

Frequency curves Technical data pre-amplifier Current consumption Transducer excitation voltage Frequency range Range of tolerance RL=100k; Ce=3.3nF; Ce=22pF RL=100k; Ce=5,6pF Gain RL=100k; Ce=22pF RL=100k; Ce=22pF RL=100k; Ce=22pF RL=100k; Ce=5.6pF RL=100k; Ce=5.6pF RL=100k; Ce=5.6pF Input impedance Output impedance Inherent noise A-weighted; RL=100k; Ce=22pF linear 20Hz to 20 kHz; RL=100k; Ce=22pF A-weighted; RL=100k; Ce=5.6pF linear 20Hz to 20kHz; RL=100k; Ce=5.6pF Plug microphone capsule Polarization voltage Frequency range Open-circuit Sensitivity Max. SPL ≤ 3% THD at 1 kHz Inherent noise...

 Open the catalog to page 2

All Microtech Gefell GmbH catalogs and technical brochures

  1. MKM 403

    2  Pages

  2. MK 231 E

    2  Pages

  3. MK 231

    2  Pages

  4. KEM 975

    8  Pages

  5. MD 300

    4  Pages

  6. M 900 M910

    2  Pages

  7. UM92.1 s

    2  Pages

  8. CMV 563

    4  Pages

  9. M Cube

    8  Pages

  10. GF 1 and WN 1

    4  Pages

  11. SIS90

    2  Pages

  12. MM210

    4  Pages

  13. MV302

    2  Pages

  14. M 221

    4  Pages

  15. M 990

    2  Pages

  16. M 320

    2  Pages

  17. M 300

    2  Pages

  18. MV230

    2  Pages

  19. MV230USB

    2  Pages

  20. SIS91

    2  Pages

  21. SIS92

    2  Pages

  22. SIS93

    2  Pages

  23. WME940

    2  Pages

  24. WME950

    2  Pages

  25. Pistonfon

    2  Pages

  26. MD 100

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.