Extract from our online catalogue: zws ultrasonic sensors Current to: 2025-01-27 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] microsonic® is a registered trademark of microsonic GmbH. All rights reserved.
Open the catalog to page 1The zws sensors are among the smallest ultrasonic sensors available on the market in cuboidal housings with Teach-in buttons. > Ultrasonic sensor in miniature housing > Installation-compatible with many optical sensors > a true alternative for critical applications > Up to 250 Hz switching frequency > for fast sampling > Optionally with SoundPipe zws1 waveguide attachment > New! Twin mode or external synchronisation via SyncBox2 > Improved temperature compensation > adjustment to working conditions within 45 seconds > UL Listed to Canadian and US safety standards > 1 switching output in pnp or...
Open the catalog to page 2Description The miniature sensor housing of the zws-15 has dimensions of 20 mm x 32 mm x 12 mm. The housing’s design and mounting is compatible with many optical sensors. This facilitates the conversion to ultrasonic sensors for critical applications. For the zws sensor range 2 output versions and 6 detection ranges are available: 1 switching output, optionally in pnp or npn circuitry The Teach-in button on the top facilitates the convenient setting of the sensor. Two LEDs in the sensor housing’s upper half indicate the switching output and respectively the analogue output states. The temperature...
Open the catalog to page 3Teach-in of a switching point Method A and Method B The operating mode single switching point +8 % (Method B) is recommended by objects, which move into the detection area from the side. In this case the switching distance is set 8 % further than the actual measured distance to the object. This ensures a reliable switching distance even if the height of the objects varies slightly. NEW! Twin mode or external synchronisation If two switching zws sensors are operating too close to one another, twin mode can be selected to avoid mutual influences. This new feature is integrated in zws sensors from...
Open the catalog to page 4At a maximum detection range of 100 mm, the zws-7 can achieve a switching frequency of 250 Hz. This allows both detection of objects with a high counting frequency and extremely narrow gaps between two objects at fast machinery speeds. The zws-7 responds under 3 ms ms. Additionally fitting the new SoundPipe zws1 (Accessories) to the zws-7 markedly raises the power to detect narrow gaps between two objects at high machine speeds. Fast zws-7 - Fast zws-7/-15 with SoundPipe The zws-7, with a 250 Hz switching frequency, is particularly suitable for counting tasks at high machine speeds. Technical...
Open the catalog to page 5The zws sensors with switching output have three operating modes: Single switching point (Method A and B) Two-way reflective barrier Window mode Teach-in of a single switching point (Method A) by positioning the object to be detected within the desired distance (1) to the sensor, pressing the button for approx. 3 seconds and then pressing it once more for approx. 1 second. Ready. Teach-in of a switching point (Method A) Teach-in of a single switching point +8 % (Method B) by positioning the object to be detected within the desired distance (1) to the sensor, pressing the button for approx. 3...
Open the catalog to page 6Teach-in of a two-way reflective barrier Set the analogue output by initially positioning the object to be detected on the sensor-close window limit (1), pressing the button for approx. 3 seconds, shifting the object to the sensor-distant window limit (2) and pressing the button once more for approx. 1 second. Ready. Teach-in of an analogue characteristic or of a window with two switching points To set a window with two detection points on a single switching output, the procedure is the same as setting the analogue. NCC/NOC and rising/falling analogue characteristic curve can also be set using...
Open the catalog to page 7thus allowing measurements to be taken in drill holes and openings with diameters under 5 mm mm. Measurement can be carried out directly before the sound exit opening, since the blind zone is inside the SoundPipe. The SoundPipe zws1 is attached to the front of the zws-15 or zws-7 sensor. A typical field of application is measuring levels in microplate wells which are used in medical analysis technology. The SoundPipe zws1 can be directly placed over the opening; this makes exact positioning that much easier. The attachment can also be used in scanning gaps of only a few millimetres in width between...
Open the catalog to page 8measuring range design operating mode ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy proximity switch/reflective mode reflective barrier window mode 250 Hz Schaltfrequenz kleine quaderformige Bauform schlankes Schallfeld UL Listed echo propagation time measurement operating voltage UB 20 - 30 V d.c., reverse polarity protection type of connection 4-pin M8 initiator plug
Open the catalog to page 9output 1 switching output NOC/NCC adjustable, short-circuit-proof delay prior to availability < 300 ms inputs description external synchronisation from rectangular signal with a defined pulse input 1 synchronisation input ultrasonic transducer operating temperature storage temperature technical features/characteristics temperature compensation controls polyurethane foam, epoxy resin with glass contents IP 67 1 push-button Teach-in via push-button yes no 1 x LED green: working, 1 x LED yellow: switch status 250 Hz Schaltfrequenz kleine quaderformige Bauform schlankes Schallfeld UL Listed
Open the catalog to page 10The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.
Open the catalog to page 11measuring range design operating mode ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy proximity switch/reflective mode reflective barrier window mode 250 Hz Schaltfrequenz kleine quaderformige Bauform schlankes Schallfeld UL Listed echo propagation time measurement operating voltage UB 20 - 30 V d.c., reverse polarity protection type of connection 4-pin M8 initiator plug
Open the catalog to page 1278 Pages