extract from our online catalogue: sks ultrasonic sensors current to: 2026-10-09 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] microsonic® ist eine eingetragene Marke der microsonic GmbH. Alle Rechte vorbehalten. Änderungen vorbehalten.
Open the catalog to page 1sksThe smallest of its kind: The sks sensor in cubical housing. Highlights > Very small housing dimensions with two M3 threaded sleeves > Installation-compatible with many optical sensors > a true alternative for critical applications > IO-Link interface > for support of the new industry standard > Smart Sensor Profiles > more transparency between IO-Link Devices > Optionally with SoundPipe sks1 waveguide attachment > Improved temperature compensation > adjustment to working conditions within 45 seconds > UL Listed to Canadian and US safety standards Basics > 1 switching output in pnp or npn...
Open the catalog to page 2The sks sensor is the smallest cuboidal ultrasonic sensor from microsonic and features a housing design reduced by 33% compared to the zws sensors. The miniature housing of the sks ultrasonic sensor fits in constricted installation locations e.g. for sampling conductor boards and wafer in the electronics industry, for presence checks on conveyor bands or fill-level measurement in small containers. When capacitive or optical sensors come up against their physical limits, installation compatibility of ultrasonic sensors with many optical sensors enable their deployment: simply secured with two...
Open the catalog to page 3For the sks sensor family three output versions are available: 1 Push-Pull switching output with IO- 1 switching output, optionally in pnp- Link interface The temperature compensation of the analogue sensors profits from a significant improvement. The sensors reach their operating point only 45 seconds after activation of the operating voltage. We now compensate for the influence of self-heating and installation conditions. This brings improved precision shortly after activation of the supply voltage and in running operation. The Teach-in button on the top of the sensor allows for the convenient...
Open the catalog to page 4Teach-in of a switching point Teach-in of a two-way reflective barrier A two-way reflective barrier can be set up with the help of a permanently mounted reflector by mounting the sks sensor and the reflector. Then press the button for approx. 3 seconds and then pressing it once more for approx. 10 seconds. Now, the two-way reflective barrier has been set. Set the analogue output by initally positioning the object to the detected on the sensor-close window limit (1), pressing the button for approx. 3 seconds, shifting the object to the sensor-distant window limit and pressing the button once more...
Open the catalog to page 5NCC/NOC and rising/ falling analogue characteristic curve can also be set using the button. SoundPipe sks1 intensively bundles the sound field and allows measurements in openings with small diameters. The SoundPipe sks1 (accessory) is pushed on the transducer of the sks. IO-Link integrated in version 1.1 for sensors with Push-Pull output. The sks-15/CF/A supports the Smart Sensor Profile. You have special requirements? Nothing as simple as that. With us, you can easily find an individual solution. Let us talk about your application: +49 231 97 51 51-82.
Open the catalog to page 6scale drawing 1 x analogue 0-10 V design cuboidal design cuboidal operating mode analogue distance operating mode analogue distance kleinste quaderformige Bau-form schlankes Schallfeld UL Listed particularities kleinste quaderformige Bau- particularities form schlankes Schallfeld UL Listed means of measurement echo propagation time means of measurement echo propagation time transducer frequency blind zone operating range max. range resolution reproducibility accuracy transducer frequency blind zone operating range max. range resolution reproducibility accuracy ± 1 % (temperature drift internally...
Open the catalog to page 7Electrical Data Electrical Data operating voltage UB 15 V bis 30 V DC, verpolfest type of connection 4-pin M8 initiator plug operating voltage UB 15 V bis 30 V DC, verpolfest type of connection 4-pin M8 initiator plug output 1 analogue output switchable rising/falling delay prior to availability < 300 ms ultrasonic transducer polyurethane foam, epoxy resin with glass contents Technical Features/Characteristics scope for settings Teach-in via push-button indicators 1 x LED green: working, 1 x LED yellow: switch status output 1 analogue output current: 4-20 mA switchable rising/falling delay prior...
Open the catalog to page 8miCrOSOniC sks ultrasonic sensors
Open the catalog to page 9sks-15/D scale drawing scale drawing □ ■ i 250 mm design cuboidal operating mode lO-Link proximity switch/reflective mode reflective barrier window mode particularities kleinste quaderformige Bau- schlankes Schallfeld lO-Link Smart Sensor Profile UL Listed means of measurement echo propagation time operating mode proximity switch/reflective reflective barrier window mode particularities kleinste quaderformige Bau schlankes Schallfeld UL Listed means of measurement echo propagation time accuracy temperature drift 0.17 %/K accuracy ± 1 % (temperature drift in ternally compensated) miCrOSOniC sks...
Open the catalog to page 10Electrical Data Electrical Data operating voltage UB 10 - 30 V d.c., reverse pola- operating voltage UB 20 - 30 V d.c., reverse polarity protection rity protection voltage ripple ± 10 % voltage ripple ± 10 % no-load current < 30 mA no-load current < 25 mA consumption consumption type of connection 4-pin M8 initiator plug type of connection 3-pin M8 initiator plug output 1 switching output delay prior to availability < 300 ms input 1 control input ultrasonic transducer polyurethane foam, epoxy resin with glass contents Technical Features/Characteristics scope for settings Teach-in via push-button...
Open the catalog to page 11design cuboidal operating mode proximity switch/reflective reflective barrier window mode particularities kleinste quaderformige Bau- schlankes Schallfeld UL Listed means of measurement echo propagation time transducer frequency blind zone operating range max. range resolution reproducibility accuracy miCfO/OniC sks ultrasonic sensors