1. Catalogs
  2. microsonic
  3. pms ultrasonic sensors in washdown design

pms ultrasonic sensors in washdown design
1 /59Pages

pms ultrasonic sensors in washdown design

pms ultrasonic sensors in washdown design
1 /59Pages

Catalog excerpts

pms ultrasonic sensors in washdown design-1

Extract from our online catalogue: pms ultrasonic sensors Current to: 2025-08-21 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] microsonic® is a registered trademark of microsonic GmbH. All rights reserved.

 Open the catalog to page 1
pms ultrasonic sensors in washdown design-2

The design of the wash-down stainless steel housing with no crevices and dirt edges makes pms sensor perfectly suited to intensive cleaning and disinfection. > Innovative housing in Washdown Design > easy to clean, EHEDG certified > Two stainless-steel housings > for use in the food and pharmaceutical industry > PTFE membrane > for protection against aggressive media > Sealed against the housing with an O-ring made from FKM > for the highest possible chemical resistance > ECOLAB certified and FDA-compliant materials > IO-Link interface > for support of the new industry standard > UL Listed to...

 Open the catalog to page 2
pms ultrasonic sensors in washdown design-3

micro/onic pms ultrasonic sensors

 Open the catalog to page 3
pms ultrasonic sensors in washdown design-4

Description The pms ultrasonic sensors are designed for the most demanding hygienic requirements according to EHEDG guidelines. Two versions of the sensor are available: D12 adapter shaft and D12 bayonet catch. The standard version D12 adapter shaft is mounted with a hygienic screw connection BF-pms/A1 or an adequate mounting clip. The innovative design of the stainless steel housing ensures that the pms sensor has no horizontal surfaces in almost all conceivable installation positions. Even with horizontal installation of the hygienic sensor for measuring vertical downwards, the rear side of...

 Open the catalog to page 4
pms ultrasonic sensors in washdown design-5

1 Push-Pull switching output with pnp or npn switching technology > Single switching point > Two-way reflective barrier > Place object to be detected (1) at the desired distance > Apply +UB to pin 2 for about 3 seconds > Then apply +UB to pin 2 again for about 1 second Teach-in of a two-way reflective barrier with a fixed reflector > Apply +UB to pin 2 for about 3 seconds > Then apply +UB to pin 2 again for about 10 seconds micro/onic pms ultrasonic sensors

 Open the catalog to page 5
pms ultrasonic sensors in washdown design-6

Teach-in of a two-way reflective barrier For setting an analogue output  initially position the object to be detected on the sensor-close window limit (1) Apply +UB to pin 2 for about 3 seconds Move the object to the sensor-distant window limit (2) Then apply +UB to pin 2 again for about 1 second Teach-in of an analogue characteristic or a window with two switching points To set a window with two switching points on a single switch output, the procedure is the same as setting the analogue. NCC/NOC and rising/falling analogue characteristic curve can also be set via pin 2. LinkControl consist...

 Open the catalog to page 6
pms ultrasonic sensors in washdown design-7

Hygienie sensor connected to the PC via LCA-2 for programming With the hygienic screw connection BF-pms/A1 (accessory), the pms sensor is mounted hygienically. The screw connection has a ECOLAB and EHEDG certificate. pms sensor and sensor screw connection in wash-down design IO-Link integrated in version 1.1. The pms ultrasonic sensors are equipped with Smart Sensor Profile, which creates more transparency between IO-Link devices. Excellent set-up

 Open the catalog to page 7
pms ultrasonic sensors in washdown design-8

The compact pms ultrasonic sensor is made of stainless steel and FDA-conform materials. Ensures high resistance to cleaning agents in areas coming into contact with products in the pharmaceuticals, food and beverage industry.

 Open the catalog to page 8
pms ultrasonic sensors in washdown design-9

The innovative hygiene design was designed in accordance with EHEDG guidelines. The pms sensor version D12-adapter shaft is EHEDG-certified. Versatile applications Beverage industry The pms ultrasonic sensor detects glass and PET bottles in operating mode and withstands the cleaning intervals of filling machines. The sensor is mounted with the hygienic sensor mounting BF-pms/A1. For example, pms-25/F ... with Push-Pull switching output to count bottles.

 Open the catalog to page 9
pms ultrasonic sensors in washdown design-10

Within the food industry containers have to be counted or positioned, volume flow checked on conveyor belts, or food items have to be controlled on filling level and completeness. Two pms ultrasonic sensors monitor the completeness of apples in packaging boxes. For example, 2 x pms-25/F ... each with Push-Pull switching output for height control. Within the pharma industry ampoules and glass vials have to be counted and the volume flow in the filling level process has to be controlled. On a turntable, a pms sensor controls the volume flow of glass vials ahead of the filling line. For example, pms-35/U...

 Open the catalog to page 10
pms ultrasonic sensors in washdown design-11

Contact form micro/onic pms ultrasonic sensors

 Open the catalog to page 11
pms ultrasonic sensors in washdown design-12

detection zone scale drawing design Innovative housing design in washdown operating mode IO-Link proximity switch/reflective mode reflective barrier window mode description The pms ultrasonic sensor in stainless steel housing is designed according particularities hohe Chemiebestandigkeit Edelstahlausfuhrung IO-Link UL Listed Hygienic Design ECOLAB EHEDG (TYPE EL Class I AUX) ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy echo propagation time measurement ± 1 % (temperature drift internally compensated)

 Open the catalog to page 12
pms ultrasonic sensors in washdown design-13

pms-15/CF/A1 electrical data operating voltage UB 10 - 30 V d.c., reverse polarity protection voltage ripple no-load current consumption

 Open the catalog to page 13
pms ultrasonic sensors in washdown design-14

switching hysteresis switching frequency response time delay prior to availability switching output synchronisation input teach-in input IO-Link product name product ID SIO mode support COM mode min. cycle time format of process data content of process data ISDU paramter system commands Smart Sensor Profile IODD version Bit 0: Q1 switch status; Bit 8-15: scale (Int. 8); Bit 16-31: measured value (Int. 16) Identification, measuring configuration, switched output, filter, temperature compensation, operation SP1 Teach-in, SP2 Teach-in, factory settings ultrasonic transducer cleaning temperature...

 Open the catalog to page 14
pms ultrasonic sensors in washdown design-15

pms-15/CF/A1 technical features/characteristics temperature compensation Teach-in via com input on pin 2 LCA-2 with LinkControl IO-Link yes, via external clock generator hohe Chemiebeständigkeit Edelstahlausführung IO-Link UL Listed Hygienic Design ECOLAB EHEDG (TYPE EL Class I AUX) The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.

 Open the catalog to page 15
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.