extract from our online catalogue: pms ultrasonic sensors current to: 2026-10-09 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] microsonic® ist eine eingetragene Marke der microsonic GmbH. Alle Rechte vorbehalten. Änderungen vorbehalten.
Open the catalog to page 1pms The design of the wash-down stainless steel housing with no crevices and dirt edges makes pms sensor perfectly suited to intensive Highlights Basics > Innovative housing in Washdown Design > easy to clean, EHEDG certified > Two stainless-steel housings > for use in the food and pharmaceutical industry > PTFE membrane > for protection against aggressive media > Sealed against the housing with an O-ring made from FKM > for the highest possible chemical resistance > ECOLAB certified and FDA-compliant materials > IO-Link interface > for support of the new industry standard > UL Listed to Canadian...
Open the catalog to page 2The pms ultrasonic sensors are designed for the most demanding hygienic requirements according to EHEDG guidelines. Two versions of the sensor are available: D12 adapter shaft and D12 bayonet catch. The standard version D12 adapter shaft is mounted with a hygienic screw connection BF-pms/A1 or an adequate mounting clip. The innovative design of the stainless steel housing ensures that the pms sensor has no horizontal surfaces in almost all conceivable installation positions. Even with horizontal installation of the hygienic sensor for measuring vertical downwards, the rear side of the housing...
Open the catalog to page 3Excellent set-up The compact pms ultrasonic sensor is made of stainless steel and FDAconform materials. Ensures high resistance to cleaning agents in areas coming into contact with products in the pharmaceuticals, food and beverage industry. The innovative hygiene design was designed in accordance with EHEDG guidelines. The pms sensor version D12-adapter shaft is EHEDGcertified. Versatile applications in the beverage, food, and pharmaceutical industries
Open the catalog to page 4Beverage industry The pms ultrasonic sensor detects glass and PET bottles in operating mode and withstands the cleaning intervals of filling machines. The sensor is mounted with the hygienic sensor mounting BF-pms/A1. For example, pms-25/F ... with Push-Pull switching output to count bottles. Within the pharma industry ampoules and glass vials have to be counted and the volume flow in the filling level process has to be controlled. On a turntable, a pms sensor controls the volume flow of glass vials ahead of the filling line. For example, pms-35/U ... with voltage output 0-10 V. Within the food...
Open the catalog to page 5> Place object to be detected (1) at the desired distance > Apply +UB to pin 2 for about 3 seconds > Then apply +UB to pin 2 again for about 1 second Teach-in of a switching point Teach-in of a two-way reflective barrier with a fixed reflector > Apply +UB to pin 2 for about 3 seconds > Then apply +UB to pin 2 again for about 10 seconds > initially position the object to be detected on the sensor-close window limit (1) > Apply +UB to pin 2 for about 3 seconds > Move the object to the sensor-distant window limit (2) > Then apply +UB to pin 2 again for about 1 second miCrOSOniC pms ultrasonic sensors...
Open the catalog to page 6Teach-in of an analogue characteristic or a window with two switching points To set a window with two switching points on a single switch output, the procedure is the same as setting the analogue. NCC/NOC and rising/falling analogue characteristic curve can also be set via pin 2. LinkControl consist of LinkControl-Adapter LCA-2 and LinkControl-Software and permits the configuration of pms sensors via PC or laptop with all conventional Windows® operating systems. For configuration of pms sensors, the additional adapter Adapter 5G/M124G/M12/M8 needed
Open the catalog to page 7Sensor connected to the PC via LCA-2 for programming With the hygienic screw connection BF-pms/A1 (accessory), the pms sensor is mounted hygienically. The screw connection has a ECOLAB and EHEDG certificate. IO-Link integrated in version 1.1. The pms ultrasonic sensors are equipped with Smart Sensor Profile, which creates more transparency between IO-Link devices. You have special requirements? Nothing as simple as that. With us, you can easily find an individual solution. Let us talk about your application: +49 231 97 51 51-82.
Open the catalog to page 8scale drawing scale drawing 1 x analogue 4-20 mA Innovative housing design in design Innovative housing design in washdown operating mode analogue distance particularities stainless steel version high chemical resistance UL Listed Hygienic Design ECOLAB EHEDG (TYPE EL Class I AUX) operating mode analogue distance particularities stainless steel version high chemical resistance UL Listed Hygienic Design ECOLAB EHEDG (TYPE EL Class I AUX) means of measurement echo propagation time means of measurement echo propagation time transducer frequency blind zone operating range max. range resolution reproducibility...
Open the catalog to page 9guidelines. guidelines. miCrOSOniC pms ultrasonic sensors
Open the catalog to page 10miCrOSOniC pms ultrasonic sensors
Open the catalog to page 11scale drawing scale drawing design Innovative housing design in operating mode analogue distance particularities stainless steel version high chemical resistance UL Listed Hygienic Design ECOLAB EHEDG (TYPE EL Class I AUX) Innovative housing design in washdown operating mode analogue distance particularities stainless steel version high chemical resistance UL Listed Hygienic Design ECOLAB EHEDG (TYPE EL Class I AUX) miCrOSOniC pms ultrasonic sensors
Open the catalog to page 12transducer frequency blind zone operating range max. range resolution voltage ripple no-load current consumption response delay delay prior to availability ultrasonic transducer operating temperature storage temperature weight echo propagation time measurement 0.069 mm to 0.10 mm, depending on the analogue window ± 1 % (temperature drift internally compensated) 10 - 30 V d.c., reverse polarity protection analogue output current: 4-20 mA switchable rising/falling com input teach-in input stainless steel coated with PTFE film, FKM O-ring transducer frequency blind zone operating range max. range...