1. Catalogs
  2. microsonic
  3. mic ultrasonic sensors

mic ultrasonic sensors
1 /46Pages

mic ultrasonic sensors

mic ultrasonic sensors
1 /46Pages

Catalog excerpts

mic ultrasonic sensors-1

Extract from our online catalogue: mic ultrasonic sensors Current to: 2025-01-27 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] microsonic® is a registered trademark of microsonic GmbH. All rights reserved.

 Open the catalog to page 1
mic ultrasonic sensors-2

These completely metal mic sensors are available in two device designs with five different detection ranges. > M30 housing and M12 circular connector in metal design > for harsh usage conditions > Automatic synchronisation > for simultaneous operation of up to ten sensors in close quarters > UL Listed to Canadian and US safety standards > 1 switching output in pnp variant > Analogue output 4-20 mA and 0-10 V > with automatic switching between current and voltage outputs > 5 detection ranges with a measurement range of 30 mm to 8 m > LinkControl > for configuration of sensors from a PC micro/onic...

 Open the catalog to page 2
mic ultrasonic sensors-3

Description This very solid construction is fully made of metal from the M30 housing to the M12 circular connector. Since the sensors do not contain any operating elements or signal lamps, they are especially suited for application under extreme ambient conditions with high mechanical loads for housing and plug connector. The sensors are available in five detection ranges and cover a measuring range of 30 mm up to 8 m. M12 metal circular connector (left) and operation under rough conditions (right) Two output levels are available for all five detection ranges: Sensors with switching output have...

 Open the catalog to page 3
mic ultrasonic sensors-4

Teach-in of a switching point Teach-in of a two-way reflective barrier with a fixed reflector  Apply +UB to pin 5 for about 3 seconds Then apply +UB to pin 5 again for about 10 seconds Teach-in of a two-way reflective barrier Place object at the near edge of the window (1) Apply +UB to pin 5 for about 3 seconds Then move the object to the far edge of the window (2) Then apply +UB to pin 5 again for about 1 seconds Teach-in of an analogue characteristic or a window with two switching points

 Open the catalog to page 4
mic ultrasonic sensors-5

NCC/NOC and rising/falling analogue characteristic curve can also be set via pin 5. LinkControl optionally permits the extensive parameterisation of mic sensors. The LCA-2 LinkControl adapter , which is available as an accessory, can be used to connect mic sensors to the PC. Sensor connected to the PC via LCA-2 for programming Synchronisation permits the simultaneous use of multiple mic sensors in an application. To avoid mutual interference, the sensors can be synchronised with one another. To do this, all the sensors are electrically connected on pin 5. If more than 10 sensors need to be synchronised,...

 Open the catalog to page 5
mic ultrasonic sensors-6

measuring range design operating mode ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy proximity switch/reflective mode reflective barrier window mode metal plug for harsh operational conditions echo propagation time measurement ± 1 % (temperature drift internally compensated) operating voltage UB 9 - 30 V d.c., reverse polarity protection type of connection 5-pin M12 initiator plug

 Open the catalog to page 6
mic ultrasonic sensors-7

output 1 switching output NOC/NCC adjustable, short-circuit-proof delay prior to availability < 390 ms inputs teach-in input ultrasonic transducer operating temperature storage temperature further versions technical features/characteristics temperature compensation controls brass sleeve, nickel-plated, plastic parts, PBT polyurethane foam, epoxy resin with glass contents IP 67 cable connection (on request) yes com input control input Teach-in via com input on pin 5 LCA-2 with LinkControl metal plug for harsh operational conditions

 Open the catalog to page 7
mic ultrasonic sensors-8

The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.

 Open the catalog to page 8
mic ultrasonic sensors-9

scale drawing measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy analogue distance measurements metal plug for harsh operational conditions echo propagation time measurement ± 1 % (temperature drift internally compensated) operating voltage UB 9 - 30 V d.c., reverse polarity protection type of connection 5-pin M12 initiator plug

 Open the catalog to page 9
mic ultrasonic sensors-10

output 1 analogue output current: 4-20 mA / voltage: 0-10 V (at UB > 15 V), short-circuit-proof switchable rising/falling delay prior to availability < 390 ms inputs teach-in input ultrasonic transducer operating temperature storage temperature further versions technical features/characteristics temperature compensation controls brass sleeve, nickel-plated, plastic parts, PBT polyurethane foam, epoxy resin with glass contents IP 67 cable connection (on request) yes com input control input Teach-in via com input on pin 5 LCA-2 with LinkControl metal plug for harsh operational conditions

 Open the catalog to page 10
mic ultrasonic sensors-11

The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.

 Open the catalog to page 11
mic ultrasonic sensors-12

measuring range design operating mode ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy proximity switch/reflective mode reflective barrier window mode metal plug for harsh operational conditions echo propagation time measurement ± 1 % (temperature drift internally compensated) operating voltage UB 9 - 30 V d.c., reverse polarity protection type of connection 5-pin M12 initiator plug

 Open the catalog to page 12
mic ultrasonic sensors-13

output 1 switching output NOC/NCC adjustable, short-circuit-proof delay prior to availability < 420 ms inputs teach-in input ultrasonic transducer operating temperature storage temperature further versions further versions technical features/characteristics temperature compensation controls brass sleeve, nickel-plated, plastic parts, PBT polyurethane foam, epoxy resin with glass contents IP 67 cable connection (on request) mic-35/D/M/K6 com input control input Teach-in via com input on pin 5 LCA-2 with LinkControl metal plug for harsh operational conditions

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.