extract from our online catalogue: lpc+ ultrasonic sensors current to: 2026-10-09 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] microsonic® ist eine eingetragene Marke der microsonic GmbH. Alle Rechte vorbehalten. Änderungen vorbehalten.
Open the catalog to page 1lpc+l pc + well equipped: 2 Push-Pull switching outputs or 1 Push-Pull switching output with an analogue output in M18 housing. Highlights > Analogue output 4-20 mA or 0-10 V plus 1 Push-Pull switching output in > lO-Link interface > for support of the new industry standard > Smart Sensor Profiles > more transparency between lO-Link Devices > Improved temperature compensation > adjustment to working conditions within 120 seconds > UL Listed to Canadian and US safety standards Basics > 2 Push-Pull switching outputs > pnp or npn basis > 4 detection ranges with a measurement range of 20 mm to 1.3...
Open the catalog to page 2The lpc+ ultrasonic sensors are optionally equipped with two Push-Pull switching outputs or an analogue output plus a Push-Pull switching output. The compact series with M18 threaded sleeves coves four detection ranges from 20 mm to 1.3 m. Ultrasonic sensors with the Push-Pull output stage support SIO and IO-Link modes. Sensors with analogue output are optionally available with 4–20 mA current output or 0–10 V voltage output.In SIO mode, sensors are configured using the microsonic Teach-in procedure on pin 5. two output stages: 2 output stages and 4 detection ranges available: 2 Push-Pull-switching...
Open the catalog to page 3Teach-in of a switching point Teach-in of a two-way reflective barrier Teach-in of a two-way reflective barrier with a fixed reflector Apply +UB to pin 5 for about 3 seconds Then apply +UB to pin 5 again for about 10 seconds Place object at the near edge of the window (1) Apply +UB to pin 5 for about 3 seconds Then move the object to the far edge of the window (2) Then apply +UB to pin 5 again for about 1 second Teach-in of an analogue characteristic or a window with two switching points NCC/NOC and rising/falling analogue characteristic curve can also be set via pin 5. lpc+ ultrasonic sensor...
Open the catalog to page 4LinkControl optionally permits the extensive parameterisation of lpc+ sensors. The LCA-2 LinkControl adapter , which is available as an accessory, can be used to connect lpc+ sensors to the PC. Sensor connected to the PC via LCA-2 for programming Easy to synchronise A number of lpc+ ultrasonic sensors can be run closely packed in applications synchronised to stop them from influencing one another. To this end, the sync mode has to be activated and all the sensors are to be electrically connected one to another with pin 5. If more than 10 sensors must be synchronised, this can be carried out with...
Open the catalog to page 5IO-Link integrated in version 1.1. The lpc+ ultrasonic sensors are equipped with Smart Sensor Profile, which creates more transparency between IO-Link devices. You have special requirements? Nothing as simple as that. With us, you can easily find an individual solution. Let us talk about your application: +49 231 97 51 51-82. lpc+ ultrasonic sensors
Open the catalog to page 6lpc+15/WK/CFF scale drawing scale drawing 2 x Push-Pull transducer frequency blind zone operating range max. range resolution reproducibility accuracy operating mode lO-Link proximity switch/reflective mode reflective barrier window mode particularities IO-Link means of measurement echo propagation time ± 1 % (temperature drift internally compensated) operating mode IO-Link proximity switch/reflective mode reflective barrier window mode Smart Sensor Profile UL Listed means of measurement echo propagation time accuracy ± 1 % (temperature drift in ternally compensated)
Open the catalog to page 7voltage ripple no-load current consumption Ausgang 2 switching hysteresis switching frequency response delay delay prior to availability ultrasonic transducer operating temperature storage temperature weight further versions further versions 10 - 30 V d.c., reverse polarity protection switching output Push-Pull, Ub-3 V, -Ub+3 V,Imax = 100 mA NOC/NCC adjustable, short-circuit-proof switching output Push-Pull, Ub-3 V, -Ub+3 V,Imax = 100 mA NOC/NCC adjustable, short-circuit-proof synchronisation input teach-in input brass sleeve, nickel-plated, plastic parts, PBT, PA polyurethane foam, epoxy resin...
Open the catalog to page 8Technical Features/Characteristics scope for settings Teach-in via com input on LCA-2 with LinkControl lO-Link Technical Features/Characteristics scope for settings Teach-in via com input on LCA-2 with LinkControl IO-Link miCfO/OniC lpc+ ultrasonic sensors
Open the catalog to page 9lpc+15/WK/CFI scale drawing scale drawing 1 x Push-Pull + 1 x analog 4-20 mA transducer frequency blind zone operating range max. range reproducibility accuracy operating mode lO-Link proximity switch/reflective mode reflective barrier window mode analogue distance measurement particularities IO-Link Smart Sensor Profile means of measurement echo propagation time ± 1 % (temperature drift internally compensated) operating mode IO-Link proximity switch/reflective mode reflective barrier window mode analogue distance measurement particularities 90° angular head Smart Sensor Profile means of measurement...
Open the catalog to page 10voltage ripple no-load current consumption Ausgang 2 switching hysteresis switching frequency response delay delay prior to availability ultrasonic transducer operating temperature storage temperature weight further versions further versions 10 - 30 V d.c., reverse polarity protection analogue output current: 4-20 mA switchable rising/falling switching output Push-Pull, Ub-3 V, -Ub+3 V,Imax = 100 mA NOC/NCC adjustable, short-circuit-proof synchronisation input teach-in input brass sleeve, nickel-plated, plastic parts, PBT, PA polyurethane foam, epoxy resin with glass contents voltage ripple no-load...
Open the catalog to page 11Technical Features/Characteristics scope for settings Teach-in via com input on LCA-2 with LinkControl lO-Link Technical Features/Characteristics scope for settings Teach-in via com input on LCA-2 with LinkControl IO-Link miCfO/OniC lpc+ ultrasonic sensors