Extract from our online catalogue: lcs+ ultrasonic sensors Current to: 2025-01-27 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] microsonic® is a registered trademark of microsonic GmbH. All rights reserved.
Open the catalog to page 1The new lcs+ ultrasonic sensors come in a very compact square-shaped housing - with analogue or switching output + lO-Link. HIGHLIGHTS > Very compact housing dimensions > only 62 mm x 62 mm x > 37.2> mm > IO-Link interface > for support of the new industry standard > Synchronisation and multiplex mode > for simultaneous operation of up to ten sensors in close quarters > 8 m maximum detection range > UL Listed to Canadian and US safety standards > Smart Sensor Profiles > more transparency between IO-Link Devices > 1 Push-Pull switching output, or 2 pnp switching outputs > Analogue output 4-20...
Open the catalog to page 2have a block-like plastic housing with a base area of only 62 x 62 mm and four fastening bores. The sensors are Listed to applicable UL Standards and requirements by UL for Canada and the US. show all operating statuses. 1 Push-Pull switching output with pnp or npn switching technology the lcs+ sensors can be easily set. > Single switching point > Two-way reflective barrier > Place object to be detected (1) at the desired distance > Push button T2 for about 3 seconds > Then push button T2 again for about 1 second micro/onic lcs+ ultrasonic sensors
Open the catalog to page 3Teach-in of a two-way reflective barrier with a fixed mounted reflector > Push button T1 for about 3 seconds > Then push button T1 again for about 10 seconds Teach-in of a two-way reflective barrier > Initially position the object to be detected to the sensor-close window limit (1) > Push button T1 for about 3 seconds > Then move the object to the sensor-distant window limit (2) > Then push button T1 again for about 1 second micro/onic lcs+ ultrasonic sensors
Open the catalog to page 4Teach-in of an analogue characteristic or a window with two switching points For configuration of a window with two switching points on a single switched output, the procedure is the same as setting the analogue. Analogue sensors check the connected working resistance at the output and automatically switch to 4–20 mA current output or 0–10 V voltage output. NCC/NOC and rising/falling analogue characteristics can also be set via the buttons. LinkControl permits comprehensive parameterisation of lcs+ ultrasonic sensors via the LinkControl adapter LCA-2 which connects the sensors to the PC. Sensor...
Open the catalog to page 5If more than 10 sensors must be synchronised, this can be carried out with the SyncBox1 , which is available as an accessory. Synchronisation via pin 5 is also possible in IO-Link mode. IO-Link Ultrasonic sensors lcs+340/F/A and lcs+600/F/A have a Push-Pull switching output and support IO-Link in version 1.1 as well as the Smart Sensor profile. lcs+ ultrasonic sensors
Open the catalog to page 6scale drawing detection zone 1 x Push-Pull measuring range design operating mode ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy proximity switch/reflective mode reflective barrier window mode Smart Sensor Profile UL Listed echo propagation time measurement ± 1 % (temperature drift internally compensated) operating voltage UB 9 - 30 V d.c., reverse polarity protection type of connection 5-pin M12 initiator plug
Open the catalog to page 7output 1 switching output synchronisation input IO-Link product name product ID SIO mode support COM mode min. cycle time format of process data content of process data ISDU paramter system commands Smart Sensor Profile IODD version ultrasonic transducer operating temperature storage temperature Bit 0: initial state Pin 4; Bit 8-15: scale (Int. 8); Bit 16-31: measured value (Int. 16) Identification, measuring configuration, switched output, filter, temperature compensation, operation SP1 Teach-in, SP2 Teach-in, factory settings polyurethane foam, epoxy resin with glass contents IP 67
Open the catalog to page 8lcs+340/F/A technical features/characteristics temperature compensation Teach-in via push-button LCA-2 with LinkControl IO-Link IO-Link Smart Sensor Profile UL Listed The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features. lcs+ ultrasonic sensors
Open the catalog to page 9scale drawing detection zone measuring range design operating mode ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy proximity switch/reflective mode reflective barrier window mode echo propagation time measurement ± 1 % (temperature drift internally compensated) electrical data operating voltage UB 9 - 30 V d.c., reverse polarity protection no-load current consumption < 60 mA
Open the catalog to page 10output 1 switching output NOC/NCC adjustable, short-circuit-proof output 2 switching output NOC/NCC adjustable, short-circuit-proof delay prior to availability synchronisation input ultrasonic transducer operating temperature storage temperature polyurethane foam, epoxy resin with glass contents IP 67 technical features/characteristics temperature compensation controls Teach-in via push-button LCA-2 with LinkControl micro/onic lcs+ ultrasonic sensors
Open the catalog to page 11The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features. lcs+ ultrasonic sensors
Open the catalog to page 12scale drawing detection zone measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy analogue distance measurements UL Listed echo propagation time measurement 0.18 mm to 1.5 mm, depending on the analogue window ± 0.15 % ± 1 % (temperature drift internally compensated) operating voltage UB 9 - 30 V d.c., reverse polarity protection type of connection 5-pin M12 initiator plug